3D diffusion tensor imaging with 2D navigated turbo spin echo

被引:2
|
作者
von Mengershausen, M
Norris, DG
Driesel, W
机构
[1] Max Planck Inst Human Cognit & Brain Sci, D-04103 Leipzig, Germany
[2] FC Donders Ctr Cognit Neuroimaging, NL-6500 HB Nijmegen, Netherlands
关键词
3D DTI; 2D navigator; motion correction; Eddy-current compensation; high resolution; isotropic voxels;
D O I
10.1007/s10334-005-0118-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Cartesian two-dimensional navigator with variable orientation for online motion correction is introduced. It corrects for all possible zeroth- and first-order phase errors due to rigid-body motion of a subject during the diffusion-weighting preparation. The technique is developed for the application of three-dimensional (3D) imaging sequences, which offer the opportunity of high-resolution diffusion-weighted imaging, or diffusion tensor imaging (DTI) with isotropic voxel resolution. The navigator was applied to a displaced 3D turbo spin-echo sequence with an ECG-gated diffusion preparation to avoid phase errors due to gross brain pulsation. Online and offline corrected in vivo images acquired with this sequence are compared to investigate the advantages of online correction. Also eigenvector maps of the diffusion tensor are presented with an isotropic resolution of 1 mm(3), which indicate that this new navigator technique is a promising approach for high-resolution DTI.
引用
收藏
页码:206 / 216
页数:11
相关论文
共 50 条
  • [31] The Role of 2D and 3D Echo in Mitral Stenosis
    Monteagudo Ruiz, Juan Manuel
    Gomez, Jose Luis Zamorano
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (12)
  • [32] Accuracy of 2D BLADE Turbo Gradient- and Spin-Echo Diffusion Weighted Imaging for the Diagnosis of Primary Middle Ear Cholesteatoma
    Lin, Mengyan
    Sha, Yan
    Sheng, Yaru
    Chen, Wei
    OTOLOGY & NEUROTOLOGY, 2022, 43 (06) : E651 - E657
  • [33] Management of Mitral Stenosis Using 2D and 3D Echo-Doppler Imaging
    Wunderlich, Nina C.
    Beigel, Roy
    Siegel, Robert J.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (11) : 1191 - 1191
  • [34] Hybrid 2D–3D ultrasound registration for navigated prostate biopsy
    Sonia-Yuki Selmi
    Emmanuel Promayon
    Jocelyne Troccaz
    International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 987 - 995
  • [35] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [36] 3D fast spin echo imaging of prostate carcinoma
    Bradley, WG
    Hasson, R
    Chen, D
    Rogall, B
    Soong, JC
    Mandelker, EM
    RADIOLOGY, 1998, 209P : 260 - 260
  • [37] Detection of cholesteatoma: 2D BLADE turbo gradient- and spin-echo imaging versus readout-segmented echo-planar diffusion-weighted imaging
    Lin, Mengyan
    Lin, Naier
    Sheng, Yaru
    Sha, Yan
    Zhang, Zhongshuai
    Zhou, Kun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5223 - 5229
  • [38] Detection of cholesteatoma: 2D BLADE turbo gradient- and spin-echo imaging versus readout-segmented echo-planar diffusion-weighted imaging
    Mengyan Lin
    Naier Lin
    Yaru Sheng
    Yan Sha
    Zhongshuai Zhang
    Kun Zhou
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 5223 - 5229
  • [39] Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement
    Mizuno, Hiroyuki
    Aihara, Masanori
    Sato, Koji
    Negishi, Chikashi
    Sasaguchi, Nobuo
    Kurihara, Hideyuki
    Yoshimoto, Yuhei
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 17 (01) : 1 - 7
  • [40] Comparison of 3D versus 2D Fast Spin-Echo Imaging for Evaluation of Articular Cartilage in the Knee on a 3 Tesla System
    Haims, A.
    Milewski, M.
    Essig, D.
    Medvecky, M.
    Katz, L.
    Moukaddam, H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)