An economic & technical evaluation of condition monitoring for new SF6 circuit breakers

被引:0
|
作者
Camps, GD [1 ]
Cumming, TA [1 ]
Gibson, D [1 ]
Olson, S [1 ]
Walker, D [1 ]
Ault, GW [1 ]
McDonald, J [1 ]
机构
[1] SP Power Syst Ltd, Bellshill ML4 3FF, Scotland
来源
UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings | 2005年
关键词
condition monitoring; economic evaluation; reliability;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
On-line condition monitoring systems for EHV SF6 circuit breakers are now commercially available from a number of manufacturers. They differ in a variety. of ways, from the type of sensors used to the overall development of the system. Apart from examining the factors that influence the economic appraisal of on-line condition monitoring, the work presented in this paper shows that the design and application of these systems must be considered carefully in order to minimise the effect on the reliability of the circuit breaker. The paper concludes with a discussion on the challenging issues that require further research in order to realise the full potential of condition monitoring.
引用
收藏
页码:85 / 88
页数:4
相关论文
共 50 条
  • [41] Monitoring particle concentrations produced by arcing in SF6 circuit breakers using a chromatic modulation probe
    Isaac, LT
    Jones, GR
    Humphries, JE
    Spencer, JW
    Hall, WB
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1999, 146 (04) : 199 - 204
  • [42] SEISMIC BEHAVIOR OF CANDLE TYPE SF6 OUTDOOR CIRCUIT-BREAKERS AND ASSOCIATED SF6 INSULATED CURRENT TRANSFORMERS
    THURIES, E
    GIRODET, A
    SERRES, E
    MEES, F
    WILLIEME, JM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (04) : 2100 - 2108
  • [43] Experimental study on fatigue characteristic of operating springs of SF6 circuit breakers
    邓集
    毛文奇
    黎治宇
    陈国平
    蒋新苗
    湖南电力, 2011, (05) : 16 - 19
  • [44] BREAKING CAPACITY OF SF6 CIRCUIT-BREAKERS AT LOW-TEMPERATURES
    PONS, A
    LECONTE, C
    WILLIEME, JM
    SABOT, A
    MORIN, C
    PONS, A
    TAISNE, JP
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1165 - 1172
  • [45] SUBTRANSMISSION CABLE AND CAPACITOR SWITCHING WITH SF6 PUFFER CIRCUIT BREAKERS.
    Donohue, E.P.
    Minutes of the Meeting - Pennsylvania Electric Association, Engineering Section, 1981,
  • [46] INSULATION COORDINATION QUALITIES OF 500-KV SF6 CIRCUIT BREAKERS
    SONNENBE.CF
    BRADO, JJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (10): : 851 - &
  • [47] EXPERIMENTAL INVESTIGATION ON ARC PHENOMENA IN SF6 PUFFER CIRCUIT-BREAKERS
    KOBAYASHI, A
    YANABU, S
    YAMASHITA, S
    OZAKI, Y
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1980, 8 (04) : 339 - 343
  • [48] QUENCHING PROCESSES OF AXIALLY INHOMOGENEOUS ARCS IN SF6 CIRCUIT-BREAKERS
    BONIN, EV
    BRUGGEMANN, G
    THIEL, HG
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1980, 8 (04) : 344 - 351
  • [49] Influence of the Shapes of Arcing Contacts on Prestrike Phenomenon in SF6 Circuit Breakers
    Homaee, Omid
    Gholami, Ahmad
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2019, 47 (08) : 4127 - 4135
  • [50] STUDY OF THE POST-RECOVERY CURRENT IN SF6 CIRCUIT-BREAKERS
    MAFTOUL, J
    BARRAULT, M
    BERNARD, G
    CHEVRIER, P
    ROWE, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (06) : 1133 - 1140