Novel three-dimensional imaging technique improves the accuracy of hepatic volumetric assessment

被引:30
|
作者
DuBray, Bernard J., Jr. [1 ]
Levy, Rebecca V. [1 ]
Balachandran, Parvathi [1 ]
Conzen, Kendra D. [1 ]
Upadhya, Gundumi A. [1 ]
Anderson, Christopher D. [1 ]
Chapman, William C. [1 ]
机构
[1] Washington Univ, Div Gen Surg, Dept Surg, St Louis, MO 63110 USA
关键词
resection < liver; post-operative dysfunction and ischaemia re-perfusion < liver; LIVER-TRANSPLANTATION; COLORECTAL-CANCER; RESECTION; IMPACT; DYSFUNCTION; DONORS;
D O I
10.1111/j.1477-2574.2011.00350.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: With pre-operative prediction of liver volume becoming increasingly important to safely carry out complex hepatic resections, the aim of the present study was to validate the accuracy of a three-dimensional (3-D) liver surgery operative planning software in performing hepatic volumetry. Methods: Between 1999 and 2007, we performed 29 live donor liver resections for transplantation. Eleven patients had pre-operative volumetry performed by radiologists from either computed tomography (CT) or magnetic resonance (MR) imaging with documentation of the corresponding specimen weight. Retrospectively, images were uploaded into Scout (TM) where 3-D models of each case were generated to perform volumetry. A correlational analysis was performed followed by an accuracy comparison. Results: Estimations by both radiologists and Scout (TM) were significantly correlated with the specimen weights, P <= 0.0001. Compared with radiologists' volumetry, Scout (TM) significantly improved overall accuracy [per cent error (PE) 20.0% +/- 5.3 vs. 32.9% +/- 5.7, P = 0.005], accuracy of CT-based estimations (PE 23.2% +/- 6.7 vs. 37.2% +/- 6.9, P = 0.023) and accuracy of the left lateral section (PE 11.1% +/- 3.9 vs. 26.6% +/- 6.8, P = 0.027). Discussion: This 3-D planning software is a valid tool for use in volumetry. Significance is greatest for CT-based models of the left lateral section. This approach gives surgeons the ability to assess volumetrics and actively plan resections.
引用
收藏
页码:670 / 674
页数:5
相关论文
共 50 条
  • [31] Volumetric live cell imaging with three-dimensional parallelized RESOLFT microscopy
    Andreas Bodén
    Francesca Pennacchietti
    Giovanna Coceano
    Martina Damenti
    Michael Ratz
    Ilaria Testa
    Nature Biotechnology, 2021, 39 : 609 - 618
  • [32] Volumetric live cell imaging with three-dimensional parallelized RESOLFT microscopy
    Boden, Andreas
    Pennacchietti, Francesca
    Coceano, Giovanna
    Damenti, Martina
    Ratz, Michael
    Testa, Ilaria
    NATURE BIOTECHNOLOGY, 2021, 39 (05) : 609 - 618
  • [33] A three-dimensional imaging technique for a directional borehole radar
    van Dongen, KWA
    van den Berg, PM
    Fokkema, JT
    SUBSURFACE AND SURFACE SENSING TECHNOLOGIES AND APPLICATIONS III, 2001, 4491 : 88 - 98
  • [34] Three-dimensional imaging technique using optical diffraction
    Tan, S
    Hart, DP
    MACHINE VISION AND THREE-DIMENSIONAL IMAGING SYSTEMS FOR INSPECTION AND METROLOGY II, 2002, 4567 : 21 - 28
  • [35] Imaging technique for three-dimensional microstructure by digital holography
    Wang, Huaying
    Zhaoa, Jie
    Wang, Guangjun
    Zhang, Yizhuo
    Wang, Dayong
    HOLOGRAPHY AND DIFFRACTIVE OPTICS III, 2008, 6832
  • [36] Three-Dimensional Imaging of Sentinel Nodes in Melanoma Using a Novel SPECT/CT Technique
    Van der Ploeg, I. M.
    Olmos, R. A. Valdes
    Kroon, B. B.
    Vogel, W. V.
    Hoefnagel, C. A.
    Nieweg, O. E.
    ANNALS OF SURGICAL ONCOLOGY, 2009, 16 : 100 - 101
  • [37] Three-dimensional imaging is a novel and reliable technique to measure total body surface area
    Rashaan, Z. M.
    Euser, A. M.
    van Zuijlen, P. P. M.
    Breederveld, R. S.
    BURNS, 2018, 44 (04) : 816 - 822
  • [38] Three-dimensional imaging: a novel, valid, and reliable technique for measuring wound surface area
    Rashaan, Z. M.
    Stekelenburg, C. M.
    van der Wal, M. B. A.
    Euser, A. M.
    Hagendoorn, B. J. M.
    van Zuijlen, P. P. M.
    Breederveld, R. S.
    SKIN RESEARCH AND TECHNOLOGY, 2016, 22 (04) : 443 - 450
  • [39] Volumetric assessment of normal fetal lungs using three-dimensional ultrasound
    Chang, CH
    Yu, CH
    Chang, FM
    Ko, HC
    Chen, HY
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07): : 935 - 942
  • [40] Accuracy of three-dimensional automated ultrasound imaging of the fetal brain
    Pluym, Ilina D.
    Kwan, Lorna
    Bolagani, Aswani
    Afshar, Yalda
    Holliman, Kerry
    Wong, Thalia
    Han, Christina S.
    Platt, Lawrence D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S641 - S641