Shrinkage assessment of low shrinkage composites using micro-computed tomography

被引:67
|
作者
Hirata, Ronaldo [1 ]
Clozza, Emanuele [2 ]
Giannini, Marcelo [3 ]
Farrokhmanesh, Ehsan [1 ]
Janal, Malvin [1 ]
Tovar, Nick [1 ]
Bonfante, Estevam A. [4 ]
Coelho, Paulo G. [1 ,2 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10012 USA
[2] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[3] Univ Estadual Campinas, Dept Restorat Dent, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[4] Univ Sao Paulo, Dept Prosthodont, Bauru Coll Dent, Bauru, SP, Brazil
关键词
polymerization; x-ray micro-computed tomography; composite resins; volume shrinkage; 3D imaging; POLYMERIZATION SHRINKAGE; CONTRACTION STRESS; RESIN-COMPOSITES; DENTAL RESINS; LEAKAGE; CONFIGURATION; ADAPTATION; KINETICS;
D O I
10.1002/jbm.b.33258
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: The aim of this study was to quantify the polymerization volumetric shrinkage of one regular and two low shrinkage bulk fill composites in class I cavities with or without an adhesive layer, using three-dimensional (3D) micro-computed tomography (CT). Methods: Class I cavity preparations (2.5 mm depth x 4 mm length x 4 mm wide) were standardized in 36 extracted human third molars, which were randomly divided in six groups (n=6 each) as follows: Group VIT (regular composite without bonding agent); Group SDR (low shrinkage flowable composite without bonding agent); Group TET (low shrinkage composite without bonding agent); Group VIT/P (regular composite with bonding agent); Group SDR/X (low shrinkage flowable composite with bonding agent); TET/T (low shrinkage composite with bonding agent). Each tooth was scanned via mu CT at cavity preparation, immediately after cavity filling, and after light-curing. Acquired CT data were imported into Amira software for analysis and volume values evaluated between steps from cavity preparation until light-curing. Results: Both low shrinkage composites showed a significantly less volumetric shrinkage than VIT. The use of dental adhesive significantly decreased the average volumetric contraction similarly for the three composites, by about 20%. Conclusion: Both low shrinkage composites showed less volumetric polymerization contraction than the regular composite. The use of dental adhesive decreased the total volumetric shrinkage for all evaluated composites. (c) 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 798-806, 2015.
引用
收藏
页码:798 / 806
页数:9
相关论文
共 50 条
  • [31] Exploring the anatomy of Linguatula serrata using micro-computed tomography
    Birckhead, Alice
    Doig, Ryan O'Hare
    Carstens, Ann
    Jenkins, David
    Shamsi, Shokoofeh
    INTERNATIONAL JOURNAL FOR PARASITOLOGY-PARASITES AND WILDLIFE, 2024, 25
  • [32] QUALITY INSPECTION ON ELECTROLYTIC CAPACITORS USING MICRO-COMPUTED TOMOGRAPHY
    Pratama, I. B. G. Putra
    Suparta, Gede B.
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2014, 2015, 9302
  • [33] Quantitative Assessment of Bone Tissue Mineralization with Polychromatic Micro-Computed Tomography
    Andrew J. Burghardt
    Galateia J. Kazakia
    Andres Laib
    Sharmila Majumdar
    Calcified Tissue International, 2008, 83
  • [34] Quantitative assessment of bone tissue mineralization with polychromatic micro-computed tomography
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Laib, Andres
    Majumdar, Sharmila
    CALCIFIED TISSUE INTERNATIONAL, 2008, 83 (02) : 129 - 138
  • [35] Retention assessment of magnetic nanoparticles in rat arteries with micro-computed tomography
    Tu, Shu-Ju
    Wu, Siao-Yun
    Wang, Fu-Sheng
    Ma, Yunn-Hwa
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1271 - 1281
  • [36] MICRO-COMPUTED TOMOGRAPHY CHARACTERIZATION OF ISOTROPIC FILLER DISTRIBUTION IN MAGNETORHEOLOGICAL ELASTOMERIC COMPOSITES
    Samal, Sneha
    Vlach, Jarmil
    Kolinova, Marcela
    Kavan, Pavel
    ADVANCED PROCESSING AND MANUFACTURING TECHNOLOGIES FOR NANOSTRUCTURED AND MULTIFUNCTIONAL MATERIALS III, 2017, : 57 - 69
  • [37] The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography
    Schouten, Corinne
    Meijer, Gert J.
    van den Beucken, Jeroen J. J. P.
    Spauwen, Paul H. M.
    Jansen, John A.
    BIOMATERIALS, 2009, 30 (27) : 4539 - 4549
  • [38] Nondestructive Assessment of Glycosaminoglycans in Engineered Cartilages Using Hexabrix-Enhanced Micro-Computed Tomography
    Long Hao Jin
    Byung Hyune Choi
    Young Jick Kim
    Hyun Ju Oh
    Byoung Ju Kim
    Xiang Yun Yin
    Byoung-Hyun Min
    Tissue Engineering and Regenerative Medicine, 2018, 15 : 311 - 319
  • [39] Assessment of Small Airway Morphology Using Micro-Computed Tomography in Patients with Interstitial Lung Disease
    Ikezoe, K.
    Coxson, H. O.
    Hague, C. J.
    Peterson, S.
    Cooper, J. D.
    Tanabe, N.
    Xu, F.
    Hogg, J. C.
    Vasilescu, D. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [40] Nondestructive Assessment of Glycosaminoglycans in Engineered Cartilages Using Hexabrix-Enhanced Micro-Computed Tomography
    Jin, Long Hao
    Choi, Byung Hyune
    Kim, Young Jick
    Oh, Hyun Ju
    Kim, Byoung Ju
    Yin, Xiang Yun
    Min, Byoung-Hyun
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2018, 15 (03) : 311 - 319