Shrinkage assessment of low shrinkage composites using micro-computed tomography

被引:67
|
作者
Hirata, Ronaldo [1 ]
Clozza, Emanuele [2 ]
Giannini, Marcelo [3 ]
Farrokhmanesh, Ehsan [1 ]
Janal, Malvin [1 ]
Tovar, Nick [1 ]
Bonfante, Estevam A. [4 ]
Coelho, Paulo G. [1 ,2 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10012 USA
[2] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[3] Univ Estadual Campinas, Dept Restorat Dent, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[4] Univ Sao Paulo, Dept Prosthodont, Bauru Coll Dent, Bauru, SP, Brazil
关键词
polymerization; x-ray micro-computed tomography; composite resins; volume shrinkage; 3D imaging; POLYMERIZATION SHRINKAGE; CONTRACTION STRESS; RESIN-COMPOSITES; DENTAL RESINS; LEAKAGE; CONFIGURATION; ADAPTATION; KINETICS;
D O I
10.1002/jbm.b.33258
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: The aim of this study was to quantify the polymerization volumetric shrinkage of one regular and two low shrinkage bulk fill composites in class I cavities with or without an adhesive layer, using three-dimensional (3D) micro-computed tomography (CT). Methods: Class I cavity preparations (2.5 mm depth x 4 mm length x 4 mm wide) were standardized in 36 extracted human third molars, which were randomly divided in six groups (n=6 each) as follows: Group VIT (regular composite without bonding agent); Group SDR (low shrinkage flowable composite without bonding agent); Group TET (low shrinkage composite without bonding agent); Group VIT/P (regular composite with bonding agent); Group SDR/X (low shrinkage flowable composite with bonding agent); TET/T (low shrinkage composite with bonding agent). Each tooth was scanned via mu CT at cavity preparation, immediately after cavity filling, and after light-curing. Acquired CT data were imported into Amira software for analysis and volume values evaluated between steps from cavity preparation until light-curing. Results: Both low shrinkage composites showed a significantly less volumetric shrinkage than VIT. The use of dental adhesive significantly decreased the average volumetric contraction similarly for the three composites, by about 20%. Conclusion: Both low shrinkage composites showed less volumetric polymerization contraction than the regular composite. The use of dental adhesive decreased the total volumetric shrinkage for all evaluated composites. (c) 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 798-806, 2015.
引用
收藏
页码:798 / 806
页数:9
相关论文
共 50 条
  • [1] Evaluation of Interfacial Gap Volume of Two Low-shrinkage Composites Using Micro-Computed Tomography
    Al Nahedh, H. N. A.
    Sibai, N. S.
    OPERATIVE DENTISTRY, 2017, 42 (06) : 658 - 668
  • [2] Assessment of cuspal deflection and volumetric shrinkage of different bulk fill composites using non-contact phase microscopy and micro-computed tomography
    Prager, Martin
    Pierce, Mark
    Atria, Pablo J.
    Sampaio, Camila
    Caceres, Eduardo
    Wolff, Mark
    Giannini, Marcelo
    Hirata, Ronaldo
    DENTAL MATERIALS JOURNAL, 2018, 37 (03) : 393 - 399
  • [3] Micro-computed tomography evaluation of volumetric polymerization shrinkage and degree of conversion of composites cured by various light power outputs
    Atria, Pablo J.
    Sampaio, Camila S.
    Caceres, Eduardo
    Fernandez, Jessica
    Reis, Andre F.
    Giannini, Marcelo
    Coelho, Paulo G.
    Hirata, Ronaldo
    DENTAL MATERIALS JOURNAL, 2018, 37 (01) : 33 - 39
  • [4] Macropores generated during shrinkage in two paddy soils using X-ray micro-computed tomography
    Bottinelli, N.
    Zhou, H.
    Boivin, P.
    Zhang, Z. B.
    Jouquet, P.
    Hartmann, C.
    Peng, X.
    GEODERMA, 2016, 265 : 78 - 86
  • [5] Fiber identification of braided composites using micro-computed tomography
    Melenka, Garrett W.
    Gholami, Ali
    COMPOSITES COMMUNICATIONS, 2021, 27
  • [6] 3D mapping of polymerization shrinkage using X-ray micro-computed tomography to predict microleakage
    Sun, Jirun
    Eidelman, Naomi
    Lin-Gibson, Sheng
    DENTAL MATERIALS, 2009, 25 (03) : 314 - 320
  • [7] Assessment of Bone Fracture Healing Using Micro-Computed Tomography
    Wee, Hwabok
    Khajuria, Deepak Kumar
    Kamal, Fadia
    Lewis, Gregory S.
    Elbarbary, Reyad A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (190):
  • [8] Micro-computed tomography analysis of tubular braided composites
    Melenka, Garrett W.
    Lepp, Eric
    Cheung, Benjamin K. O.
    Carey, Jason P.
    COMPOSITE STRUCTURES, 2015, 131 : 384 - 396
  • [9] Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography
    Bouxsein, Mary L.
    Boyd, Stephen K.
    Christiansen, Blaine A.
    Guldberg, Robert E.
    Jepsen, Karl J.
    Mueller, Ralph
    JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) : 1468 - 1486
  • [10] Alternative approach to assessment of bone quality using micro-computed tomography
    Hanson, NA
    Bagi, CM
    BONE, 2004, 35 (01) : 326 - 333