Performances of a heat exchanger and pilot boiler for the development of a condensing gas boiler

被引:46
|
作者
Lee, Seungro [1 ]
Kum, Sung-Min [2 ]
Lee, Chang-Eon [1 ]
机构
[1] Inha Univ, Dept Mech Engn, Inchon 402751, South Korea
[2] Halla Univ, Sch Mech & Automot Engn, Wonju 220712, South Korea
关键词
Condensing boiler; Heat exchanger; Pilot boiler; NO(x) and CO emissions; HELICAL BAFFLES; FLAMES;
D O I
10.1016/j.energy.2011.05.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this research, design factors for a heat exchanger and boiler were investigated using a simplified model of a heat exchanger and pilot condensing boiler, respectively. Specifications of each heat exchanger component (e.g., upper heat exchanger (UHE) and lower heat exchanger (LHE): coil heat exchanger (CHE); baffles) were investigated using a model apparatus, and the comprehensive performance of the pilot gas boiler was examined experimentally. The heating efficiency of the boiler developed was about 90% when using the optimal designed heat exchangers. Compared to a conventional Bunsen-type boiler, the heating efficiency was improved about 10%. Additionally, NO(x), and CO emissions were about 30 ppm and 160 ppm, respectively, based on a 0% O(2) basis at an equivalence ratio of 0.70, which is an appropriate operating condition. However, the pollutant emission of the boiler developed is satisfactory considering the emission performance of a condensing boiler, even though CO emission must be reduced. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3945 / 3951
页数:7
相关论文
共 50 条
  • [1] Numerical study of a condensing boiler heat exchanger
    Wen, JX
    Huang, LY
    Karayiannis, TG
    Matthews, RD
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 1996, 1996, : 591 - 596
  • [2] Polymer heat exchanger design for condensing boiler applications
    Trojanowski, R.
    Butcher, T.
    Worek, M.
    Wei, G.
    APPLIED THERMAL ENGINEERING, 2016, 103 : 150 - 158
  • [3] Computational model for a condensing boiler with finned tubes heat exchanger
    Antonescu, Nicolae
    Stanescu, Paul-Dan
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 555 - 562
  • [4] Evaluation of retrofitting a conventional natural gas fired boiler into a condensing boiler
    Che, DF
    Liu, YH
    Gao, CY
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (20) : 3251 - 3266
  • [5] Parametric and economic analysis of condensing heat exchanger combined with organic rankine cycle for heat and water recovery from boiler flue gas
    Ghamati, Erfan
    Roudaki, Javad M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (06) : 1295 - 1307
  • [6] Study on Thermal Efficiency of Gas-Fired Vacuum Hot Water Boiler with Installing Flue Gas Condensing Waste-Heat Exchanger
    Pan, Zhixin
    Niu, Jiahui
    Lu, Chunping
    Zhang, Zhihong
    Zhu, Junjun
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [7] Integrated external heat exchanger for CFB boiler
    Xiong, Bin
    Lu, Xiaofeng
    Liu, Hanzhou
    Chen, Jihui
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2007, 58 (10): : 2485 - 2492
  • [8] Development of a new external heat exchanger for a circulating fluidized bed boiler
    Wang, QH
    Luo, ZY
    Fang, MX
    Ni, MJ
    Cen, KF
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2003, 42 (04) : 327 - 335
  • [9] Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler
    Cao, Weixue
    Liu, Fengguo
    You, Xue-yi
    HEAT AND MASS TRANSFER, 2018, 54 (07) : 1951 - 1960
  • [10] Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler
    Weixue Cao
    Fengguo Liu
    Xue-yi You
    Heat and Mass Transfer, 2018, 54 : 1951 - 1960