Determination of the glomerular filtration rate in patients with type 2 diabetes: An assessment of the agreement between 51Cr-EDTA plasma clearance and 99mTc-DTPA plasma clearance, 99mTc-DTPA renography and plasma creatinine prediction equation

被引:5
|
作者
Moralidis, Efstratios [1 ]
Papanastasiou, Emmanouil [2 ]
Didangelos, Triantafyllos [3 ]
Hilidis, Ilias [4 ]
Siountas, Anastasios [2 ]
Arsos, Georgios [1 ]
机构
[1] Aristotle Univ Thessaloniki, Papageorgiou Hosp, Dept Nucl Med, Fac Med,Sch Hlth Sci, Ring Rd, Thessaloniki 56429, Greece
[2] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Fac Med, Sch Hlth Sci,Lab Med Phys, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
[3] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Fac Med, Sch Hlth Sci,Propedeut Dept Internal Med 1, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
[4] AHEPA Univ Hosp, Dept Nucl Med, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
关键词
Cr-51-EDTA; CKD-EPI; Diabetic nephropathy; Gates' method; Glomerular filtration rate; Tc-99m-DTPA; RENAL CLEARANCE; GFR; SAMPLE; TC-99(M)-DTPA; SCINTIGRAPHY; GUIDELINES; VALUES; INULIN; ACID; DTPA;
D O I
10.1016/j.diabres.2020.108079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To investigate the agreement of glomerular filtration rate (GFR) determination between Cr-51- ethylenediaminetetraacetic acid (Cr-51- EDTA) plasma clearance (GFR(EDTA)) and Tc-99m-diethylenetriaminepentaacetic acid (Tc-99m-DTPA) plasma clearance (GFR(DTPA)), the Gates Tc-99m- DTPA renographic method (GFRGates) and the serum creatinine Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI, GFR(SCr)) in patients with type 2 diabetes mellitus (T2DM). Methods: Ninety-nine T2DM patients underwent GFR determinations simultaneously with Cr-51-EDTA and Tc-99m-DTPA (using the slope-intercept technique and the Brochner-Mortensen correction) and also with GFR(Gates) and GFR(SCr). Results: In the comparison between GFR(EDTA) versus GFR(DTPA), GFR(Gates) and GFR(SCr), the Bland-Altman statistic provided 0.0 +/- 13.2, 17.4* +/- 28.8 and -5.9* +/- 30.1 (*p < 0.001 for the difference from 0). Lin's concordance correlation coefficient showed substantial (0.976), poor (0.737) and poor (0.872) agreement, respectively. The proportion of the index results within the 30% and 10% of GFR(EDTA) measurements were 95% and 74% for GFR(DTPA), 53% and 19% for GFR(Gates), and 83% and 26% for GFR(SCr), respectively. Conclusion: In T2DM patients, a clinically acceptable agreement is demonstrated between Cr-51-EDTA and Tc-99m-DTPA plasma clearance for GFR measurements, suggesting conditional interchangeability between those compounds. Both the CKD-EPI prediction equation and the Gates' renographic method cannot assess GFR reliably, the latter appearing less unfailing than the former. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Comparative performance of FAS equation and Asian modified CKD-EPI in the determination of GFR in Chinese patients with CKD with the 99mTc-DTPA plasma clearance as the reference method
    Gao, Jian-Qing
    Zhao, Fu-Gang
    Huang, Jian-Min
    Shao, Fu-Qiang
    Xie, Peng
    NEFROLOGIA, 2021, 41 (01): : 27 - 33
  • [42] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Kazuo Itoh
    Annals of Nuclear Medicine, 2003, 17 : 561 - 565
  • [43] Selection of Living Kidney Donors with measured Glomerular Filtration Rate using 99mTc-DTPA compared to creatinine estimated equations
    Khelifa, A.
    Talbi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S430 - S430
  • [44] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [45] A novel, simple equation improving the accuracy of glomerular filtration rate (GFR) measurement with 99mTc-DTPA and two blood samples
    Arsos, G.
    Kalaitzoglou, A.
    Lazaridis, K.
    Katsampoukas, D.
    Moralidis, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S599 - S599
  • [46] Measuring glomerular filtration rate from plasma clearance of 51Cr-EDTA: quality assurance
    Michael Rehling
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 713 - 714
  • [47] Glomerular filtration rate determination in 99mTc-DTPA renal imaging studies using an adaptive region of interest detection method
    Tian, Cancan
    Han, Yuan
    Sun, Xiaoguang
    Huang, Qiu
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [48] Measuring glomerular filtration rate from plasma clearance of 51Cr-EDTA: quality assurance
    Rehling, Michael
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (04) : 713 - 714
  • [49] Determination of the renal functional reserve with 99mTc-DTPA with two serum samples glomerular filtration rate in Behcet Disease.
    Gul, S. S.
    Hasbek, Z.
    Erselcan, T.
    Akyol, M.
    Turgut, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S575 - S576
  • [50] Simultaneous glomerular filtration rate determination using inulin, iohexol, and 99mTc-DTPA demonstrates the need for customized measurement protocols
    White, Christine A.
    Akbari, Ayub
    Allen, Celine
    Day, Andrew G.
    Norman, Patrick A.
    Holland, David
    Adams, Michael A.
    Knoll, Greg A.