An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode

被引:77
|
作者
Gao, Qiang [1 ,2 ]
Guo, Yanyan [1 ]
Zhang, Wenyan [1 ]
Qi, Honglan [1 ,2 ]
Zhang, Chengxiao [1 ,2 ]
机构
[1] Shaanxi Normal Univ, Key Lab Analyt Chem Life Sci Shaanxi Prov, Sch Chem & Mat Sci, Xian 710062, Peoples R China
[2] Shaanxi Normal Univ, Sch Chem & Mat Sci, Minist Educ, Key Lab Appl Surface & Colloid Chem, Xian 710062, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 153卷 / 01期
关键词
Glucose biosensor; GOx-SWCNT conjugates; Layer-by-layer assembly; Redox polymer; Screen-printed electrode; DIRECT ELECTROCHEMISTRY; DIFFUSION COEFFICIENTS; TRANSFER KINETICS; ENZYME LAYERS; REDOX POLYMER; CYTOCHROME-C; OXIDASE; NANOTUBE; CONSTRUCTION; ASSEMBLIES;
D O I
10.1016/j.snb.2010.10.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric glucose biosensor based on a multilayer made by layer-by-layer assembly of single-walled carbon nanotubes modified with glucose oxidase (GOx-SWCNT conjugates) and redox polymer (PVI-Os) on a screen-printed carbon electrode (SPCE) surface was developed. The SPCE surface was functionalized with a cationic polymer by electrodeposition of the PVI-Os, followed by alternating immersions in anionic GOx-SWCNT conjugate solutions and cationic PVI-O solutions. The purpose is to build a multilayer structure which is further stabilized through the electrodeposition of PVI-Os on the multilayer film. The electrochemistry of the layer-by-layer assembly of the GOx-SWCNT conjugate/PVI-Os bilayer was followed by cyclic voltammetry. The resultant glucose biosensor provided stable and reproducible electrocatalytic responses to glucose, and the electrocatalytic current for glucose oxidation was enhanced with an increase in the number of bilayers. The glucose biosensor displayed a wide linear range from 0.5 to 8.0 mM, a high sensitivity of 32 mu A mM(-1) cm(-2), and a response time of less than 5 s. The glucose biosensor proved to be promising amperometric detectors for the flow injection analysis of glucose. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [21] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, ZQ
    Xie, F
    Shariff, M
    Arshad, M
    Ying, JY
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 339 - 346
  • [22] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, Z
    Xie, F
    Arshad, MSM
    Ying, JY
    NSTI NANOTECH 2004, VOL 1, TECHNICAL PROCEEDINGS, 2004, : 209 - 212
  • [23] Amperometric Determination of Glucose with FeO and Glucose Oxidase Bulk-Modified Screen-Printed Carbon Ink Biosensor
    Turkusic, E.
    Begic, S.
    Kahrovic, E.
    Kalcher, K.
    HEALTHMED, 2011, 5 (05): : 1117 - 1122
  • [24] Amperometric biosensors for glucose based on layer-by-layer assembled functionalized carbon nanotube and poly (neutral red) multilayer film
    Qu, Fengli
    Yang, Minghui
    Chen, Jiwei
    Shen, Guoli
    Yu, Ruqin
    ANALYTICAL LETTERS, 2006, 39 (09) : 1785 - 1799
  • [25] Layer-by-layer assemblies of chitosan/multi-wall carbon nanotubes and glucose oxidase for amperometric glucose biosensor applications
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yu, Min
    Qin, Xia
    Li, Sha
    Chen, Qiang
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (01): : 346 - 349
  • [26] The Study of Urea Nitrogen Biosensor Based on the Disposable Screen-Printed Carbon Electrode
    Chen, Jie
    Chen, Yan-Ping
    Chen, Ping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 7794 - 7802
  • [27] Disposable DNA biosensor with the carbon nanotubes–polyethyleneimine interface at a screen-printed carbon electrode for tests of DNA layer damage by quinazolines
    Júlia Galandová
    Renáta Ovádeková
    Adriana Ferancová
    Ján Labuda
    Analytical and Bioanalytical Chemistry, 2009, 394 : 855 - 861
  • [28] Carbon nanotubes-based amperometric cholesterol biosensor fabricated through layer-by-layer technique
    Guo, ML
    Chen, JH
    Li, J
    Nie, LH
    Yao, SZ
    ELECTROANALYSIS, 2004, 16 (23) : 1992 - 1998
  • [29] A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink
    Crouch, E
    Cowell, DC
    Hoskins, S
    Pittson, RW
    Hart, JP
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (05): : 712 - 718
  • [30] Amperometric biosensor based on Prussian Blue nanoparticle-modified screen-printed electrode for estimation of glucose-6-phosphate
    Banerjee, Suchanda
    Sarkar, Priyabrata
    Turner, Anthony P. F.
    ANALYTICAL BIOCHEMISTRY, 2013, 439 (02) : 194 - 200