Energy absorption in a conical cavity truncated by spherical cap subject to a focused high-intensity beam

被引:12
|
作者
Ho, CY [1 ]
Wei, PS [1 ]
机构
[1] NATL SUN YAT SEN UNIV,DEPT MECH ENGN,KAOHSIUNG 80424,TAIWAN
关键词
D O I
10.1016/S0017-9310(96)00223-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy absorption of a conical cavity truncated by a spherical cap subject to a focused beam is systematically and quantitatively investigated. The incident flux on any transverse cross-section has a Gaussian distribution, which is specified by the convergence angle, energy distribution parameter at the focal spot, and focal spot location relative to the workpiece surface. Absorption and scattering within the plasma in the cavity are assumed to be negligible. By accounting for specular and diffuse reflections the results show the effects of the spherical cap and cone angles of the cavity, locations and sizes of the focal spot, and convergence angles of the energy-beam on absorption. Asymptotic results agree with available solutions of simple models. An explanation for the occurrence of spiking in welding is also proposed. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1895 / 1905
页数:11
相关论文
共 50 条
  • [21] Energy ablative therapy of small renal tumours by laparoscopic high-intensity focused ultrasound
    Klingler, Christoph
    Mauermann, Julian
    Susani, Martin
    Seip, R.
    Marberger, Michael
    JOURNAL OF UROLOGY, 2008, 179 (04): : 216 - 216
  • [22] Reproducibility of left atrial ablation with high-intensity focused ultrasound energy in a calf model
    Villamizar, Nestor R.
    Crow, Jennifer H.
    Piacentino, Valentino, III
    DiBernardo, Louis R.
    Daneshmand, Mani A.
    Bowles, Dawn E.
    Groh, Mark A.
    Milano, Carmelo A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06): : 1381 - U208
  • [23] Laparoscopic high-intensity focused ultrasound for energy ablative therapy of small renal tumours
    Klingler, H.
    Susam, H.
    Marberger, J.
    EUROPEAN UROLOGY SUPPLEMENTS, 2008, 7 (03) : 192 - 192
  • [24] Optimization and analysis of a low-energy injector for high-intensity proton beam
    Zhou, B.
    Zhang, H.
    Zhang, P.
    Li, W.
    Hou, R.
    An, S.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (06)
  • [25] INFLUENCE OF SKIN AND SUBCUTANEOUS TISSUE ON HIGH-INTENSITY FOCUSED ULTRASOUND BEAM: EXPERIMENTAL QUANTIFICATION AND NUMERICAL MODELING
    Grisey, Anthony
    Heidmann, Marc
    Letort, Veronique
    Lafitte, Pauline
    Yony, Sylvain
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (10): : 2457 - 2465
  • [26] FOCUSED HIGH-INTENSITY PROTON-BEAM FROM A LITHIUM SOURCE BY USING AN EXB STIGMATIC SELECTOR
    LEALQUIROS, E
    PRELAS, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 636 - 638
  • [27] Beam distortion due to gold fiducial markers during salvage high-intensity focused ultrasound in the prostate
    Georgiou, P. S.
    Jaros, J.
    Payne, H.
    Allen, C.
    Shah, T. T.
    Ahmed, H. U.
    Gibson, E.
    Barratt, D.
    Treeby, B. E.
    MEDICAL PHYSICS, 2017, 44 (02) : 679 - 693
  • [28] Energy-based ablative therapy of prostate cancer: high-intensity focused ultrasound and cryoablation
    Marberger, Michael
    CURRENT OPINION IN UROLOGY, 2007, 17 (03) : 194 - 199
  • [29] HIGH-INTENSITY LASER-BEAM ATTENUATION BASED ON 2-STEP ABSORPTION MECHANISM
    PAYNE, MG
    CHEN, CH
    GARRETT, WR
    TEMPLETON, D
    JOURNAL OF APPLIED PHYSICS, 1992, 72 (09) : 4281 - 4287
  • [30] RESONANT ABSORPTION OF HIGH-INTENSITY LIGHT IN SEMICONDUCTORS WITH AN INDIRECT ENERGY-BAND STRUCTURE
    GLAZMAN, LI
    BUNTSER, DY
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1983, 17 (11): : 1239 - 1242