Reliability and agreement of a novel portable laser height metre

被引:4
|
作者
Sorensen, Gustav Valentin Blichfeldt [1 ,2 ]
Riis, Johannes [1 ,2 ]
Danielsen, Mathias Brix [1 ,2 ]
Ryg, Jesper [3 ,4 ]
Masud, Tahir [5 ]
Andersen, Stig [1 ,2 ]
Jorgensen, Martin Gronbech [1 ]
机构
[1] Aalborg Univ Hosp, Dept Geriatr Med, Aalborg, Denmark
[2] Aalborg Univ, Dept Clin Med, Aalborg, Denmark
[3] Odense Univ Hosp, Dept Geriatr Med, Odense, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[5] Nottingham Univ Hosp NHS Trust, Dept Healthcare Older People, Nottingham, England
来源
PLOS ONE | 2020年 / 15卷 / 04期
关键词
TOOL;
D O I
10.1371/journal.pone.0231449
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Human height is a simple measure with great applicability. Usually, stadiometers are used to measure height accurately. However, these may be impractical to transport and expensive. Therefore, we developed a portable and low-cost laser height metre (LHM). Objective We aimed to (1) determine intrarater and interrater reliability of our LHM and compare it to a wall-fixed stadiometer, (2) examine its agreement with the same stadiometer, and (3) determine the minimum number of recordings needed to obtain an accurate and reliable height measurement using the LHM. Methods We recruited 32 participants (18+ years)-both men and women. Two raters performed assessments on the same day blinded to each other and their reference standard measurements. We calculated intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM), and Bland-Altman plots with limits of agreement (LOA). Results For both the LHM and stadiometer, we found ICC values of 0.99-1.00 (95% CI: 0.997-1.000) for both intrarater and interrater reliability. Regarding LHM intrarater reliability, SEM, CV, and LOA were 0.34 cm, 0.16%, and -1.07 to 0.73 cm, respectively. In terms of LHM interrater reliability, SEM, CV, and LOA were 0.27 cm, 0.12%, and -0.32 to 0.84 cm, respectively. As to agreement with stadiometers using one measurement, the mean difference was -0.14 cm and LOA ranged from -0.81 to 0.77 cm. Conclusion A portable and low-cost LHM, for measuring body height once, showed an excellent reproducibility within and between raters along with an acceptable agreement with a stadiometer thereby representing a suitable alternative.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Reliability of Maximal Voluntary Contraction Related Parameters Measured by a Novel Portable Isometric Knee Dynamometer
    Sarabon, N.
    Rosker, J.
    Fruhmann, H.
    Burggraf, S.
    Loefler, S.
    Kern, H.
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2013, 23 (01) : 22 - 27
  • [42] The agreement and repeatability of tear meniscus height measurement methods
    Johnson, ME
    Murphy, PJ
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (12) : 1030 - 1037
  • [43] ATTITUDE SIMILARITY, ATTRACTION, PERCEPTION OF HEIGHT, AND JUDGMENT OF AGREEMENT
    BLEDA, PR
    BLEDA, SE
    REPRESENTATIVE RESEARCH IN SOCIAL PSYCHOLOGY, 1977, 8 (01) : 57 - 61
  • [44] Height Fluctuation Kinematic Positioning Reliability
    Takanose, Aoki
    Atsumi, Yoshiki
    Takikawa, Kanamu
    Meguro, Junichi
    PROCEEDINGS OF THE 33RD INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS+ 2020), 2020, : 2710 - 2717
  • [45] Reliability of percentage ideal weight for height
    Poustie, VJ
    Watling, RM
    Ashby, D
    Smyth, RL
    ARCHIVES OF DISEASE IN CHILDHOOD, 2000, 83 (02) : 183 - 184
  • [46] Reliability of percentage ideal weight for height
    Lask, B
    ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 84 (02) : 187 - 187
  • [47] RELIABILITY OF ADOLESCENTS REPORTS OF HEIGHT AND WEIGHT
    FORTENBERRY, JD
    JOURNAL OF ADOLESCENT HEALTH, 1992, 13 (02) : 114 - 117
  • [48] Laser diode for use in portable laser instruments
    不详
    OPTICS AND LASER TECHNOLOGY, 1996, 28 (02): : R4 - R4
  • [49] THE RELIABILITY OF HEIGHT AND HEIGHT VELOCITY IN THE ASSESSMENT OF GROWTH (THE WESSEX GROWTH STUDY)
    VOSS, LD
    WILKIN, TJ
    BAILEY, BJR
    BETTS, PR
    ARCHIVES OF DISEASE IN CHILDHOOD, 1991, 66 (07) : 833 - 837
  • [50] Portable laser exposure meter
    不详
    OPTICS AND LASER TECHNOLOGY, 1999, 31 (01): : IV - IV