Reliability and agreement of a novel portable laser height metre

被引:4
|
作者
Sorensen, Gustav Valentin Blichfeldt [1 ,2 ]
Riis, Johannes [1 ,2 ]
Danielsen, Mathias Brix [1 ,2 ]
Ryg, Jesper [3 ,4 ]
Masud, Tahir [5 ]
Andersen, Stig [1 ,2 ]
Jorgensen, Martin Gronbech [1 ]
机构
[1] Aalborg Univ Hosp, Dept Geriatr Med, Aalborg, Denmark
[2] Aalborg Univ, Dept Clin Med, Aalborg, Denmark
[3] Odense Univ Hosp, Dept Geriatr Med, Odense, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[5] Nottingham Univ Hosp NHS Trust, Dept Healthcare Older People, Nottingham, England
来源
PLOS ONE | 2020年 / 15卷 / 04期
关键词
TOOL;
D O I
10.1371/journal.pone.0231449
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Human height is a simple measure with great applicability. Usually, stadiometers are used to measure height accurately. However, these may be impractical to transport and expensive. Therefore, we developed a portable and low-cost laser height metre (LHM). Objective We aimed to (1) determine intrarater and interrater reliability of our LHM and compare it to a wall-fixed stadiometer, (2) examine its agreement with the same stadiometer, and (3) determine the minimum number of recordings needed to obtain an accurate and reliable height measurement using the LHM. Methods We recruited 32 participants (18+ years)-both men and women. Two raters performed assessments on the same day blinded to each other and their reference standard measurements. We calculated intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM), and Bland-Altman plots with limits of agreement (LOA). Results For both the LHM and stadiometer, we found ICC values of 0.99-1.00 (95% CI: 0.997-1.000) for both intrarater and interrater reliability. Regarding LHM intrarater reliability, SEM, CV, and LOA were 0.34 cm, 0.16%, and -1.07 to 0.73 cm, respectively. In terms of LHM interrater reliability, SEM, CV, and LOA were 0.27 cm, 0.12%, and -0.32 to 0.84 cm, respectively. As to agreement with stadiometers using one measurement, the mean difference was -0.14 cm and LOA ranged from -0.81 to 0.77 cm. Conclusion A portable and low-cost LHM, for measuring body height once, showed an excellent reproducibility within and between raters along with an acceptable agreement with a stadiometer thereby representing a suitable alternative.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] EQUIPPING THE COMMUNITY TO MEASURE CHILDRENS HEIGHT - THE RELIABILITY OF PORTABLE INSTRUMENTS
    VOSS, LD
    BAILEY, BJR
    ARCHIVES OF DISEASE IN CHILDHOOD, 1994, 70 (06) : 469 - 471
  • [2] Realization of metre with femtosecond laser
    Baklanov, EV
    Dmitriyev, AK
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 482 - 483
  • [3] Agreement and reliability of lower limb muscle architecture measurements using a portable ultrasound device
    Ritsche, Paul
    Schmid, Reto
    Franchi, Martino V. V.
    Faude, Oliver
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [4] A novel portable multi-wavelength laser system
    Charlton, A.
    Dickinson, B.
    LASERS IN THE CONSERVATION OF ARTWORKS, PROCEEDINGS, 2007, 116 : 641 - 647
  • [5] The pony-metre: A new device for measuring the height of equids with lasers
    Antikatzides, TG
    JOURNAL OF EQUINE VETERINARY SCIENCE, 1996, 16 (08) : 339 - 344
  • [6] Reliability and validity of 4-metre gait speed in COPD
    Kon, Samantha S. C.
    Patel, Mehul S.
    Canavan, Jane L.
    Clark, Amy L.
    Jones, Sarah E.
    Nolan, Claire M.
    Cullinan, Paul
    Polkey, Michael I.
    Man, William D-C
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42 (02) : 333 - 340
  • [7] Height and reliability of edges
    Sugiyama, T
    Abe, K
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 1997, E80D (03) : 382 - 389
  • [8] Feasibility and reliability of agricultural crop height measurement using the laser sensor array
    Alighaleh, Pejman
    Gundoshmian, Tarahom Mesri
    Alighaleh, Saeed
    Rohani, Abbas
    INFORMATION PROCESSING IN AGRICULTURE, 2024, 11 (02): : 228 - 236
  • [10] Radiographic evaluation of lumbar intervertebral disc height index: An intra and inter-rater agreement and reliability study
    Chen, Xiaolong
    Sima, Stone
    Sandhu, Harvinder S.
    Kuan, Jeff
    Diwan, Ashish D.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 103 : 153 - 162