Permanent pacemaker implantation after cardiac transplantation: Extra cost of a conservative policy

被引:1
|
作者
Holt, ND
Parry, G
Tynan, MM
Dark, JH
McComb, JM
机构
[1] Regional Cardiothoracic Centre, Freeman Hospital, Newcastle upon Tyne
[2] Regional Cardiothoracic Centre, Freeman Hospital
关键词
audit; pacemakers; cardiac transplantation;
D O I
10.1136/hrt.76.5.439
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To determine the costs of a change in permanent pacemaker implantation policy to later imp,lantation (day 21+) after cardiac transplantation. Design-Retrospective review of patient records including duration of temporary pacing, time of permanent pacemaker implantation, and length of hospital stay for every patient surviving greater than or equal to 14 days from November 1990 to August 1995 (period 2) and for all patients in whom permanent pacemakers were implanted between May 1985 and November 1990 (period 1). Setting-Supra-regional cardiopulmonary transplant unit. Patients-335 consecutive adult cardiac transplant recipients at Freeman Hospital between May 1985 and August 1995. Main outcome measures-The cost of the policy change was calculated by subtraction of the overall saving in pacemaker implantations from the overall cost of the extra inpatient stay in period 2 due to delayed implantation. Results-Mean inpatient stay per patient following cardiac transplantation of permanent pacemaker recipients in period 1 was 13.8 days compared with 23.9 days in period 2 (P < 0.001). The cost of this extended hospital stay is pound 60 095. Had the implantation policy not been changed, a further seven patients would have received a permanent pacemaker in period 2. A saving in pacemaker hardware of pound 16 275 was made. Overall, however, the new permanent pacemaker implantation policy increased expenditure by pound 43 820, assuming that permanent pacemaker implantation was the only reason for the extended hospital stay. Conclusion-The change in policy from early to later permanent pacemaker has markedly increased implantation expenditure.
引用
收藏
页码:439 / 441
页数:3
相关论文
共 50 条
  • [21] Risk factors and survival of patients with permanent pacemaker implantation after heart transplantation
    Rivinius, Rasmus
    Helmschrott, Matthias
    Rahm, Ann-Kathrin
    Darche, Fabrice F.
    Thomas, Dierk
    Bruckner, Tom
    Doesch, Andreas O.
    Ehlermann, Philipp
    Katus, Hugo A.
    Zitron, Edgar
    JOURNAL OF THORACIC DISEASE, 2019, 11 (12) : 5440 - 5452
  • [22] Permanent pacemaker implantation after cardiac surgery: Optimization of the decision making process
    Bis, Jarosaw
    Goscinska-Bis, Kinga
    Goba, Krzysztof S.
    Goco, Radosaw
    Zebalski, Marcin
    Deja, Marek A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 162 (03): : 816 - +
  • [23] Early Pacemaker Dependency After Heart Transplantation Is Associated with Permanent Pacemaker Implantation, Graft Failure and Mortality
    Darche, Fabrice F.
    Heil, Karsten M.
    Rivinius, Rasmus
    Helmschrott, Matthias
    Ehlermann, Philipp
    Frey, Norbert
    Rahm, Ann-Kathrin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (12)
  • [24] New onset of pacemaker dependency after permanent pacemaker implantation
    Nagatomo, T
    Abe, H
    Kikuchi, K
    Nakashima, Y
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (04): : 475 - 479
  • [25] Takotsubo Syndrome After Permanent Pacemaker Implantation
    Madias, John E.
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (02): : 40 - 40
  • [26] Takotsubo Cardiomyopathy after Permanent Pacemaker Implantation
    Hsu, Chen-Tung
    Chen, Cheng-Yun
    Liung, Hsin-Li
    ACTA CARDIOLOGICA SINICA, 2010, 26 (04) : 264 - 267
  • [27] Pneumopericardium and pneumothorax after permanent pacemaker implantation
    Sebastian, CC
    Wu, WC
    Shafer, M
    Choudhary, G
    Patel, PM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05): : 466 - 468
  • [28] LIFE EXPECTANCY AFTER PERMANENT PACEMAKER IMPLANTATION
    CHOKSHI, AB
    FRIEDMAN, HS
    VASAVADA, BC
    CLINICAL RESEARCH, 1980, 28 (03): : A609 - A609
  • [29] The issue of permanent pacemaker implantation following cardiac surgery
    Toth Roland
    Tahin Tamas
    Riba Adam
    Rashed Aref
    ORVOSI HETILAP, 2020, 161 (31) : 1271 - 1280
  • [30] PERMANENT CARDIAC-PACEMAKER IMPLANTATION IN THE FETAL LAMB
    SCAGLIOTTI, D
    PRINGLE, KC
    GALLASTEGUI, JL
    SHIMOKOCHI, DD
    CLINICAL RESEARCH, 1985, 33 (04): : A817 - A817