Effect of reinforcement detailing on performance of composite connections with headed studs

被引:20
|
作者
Kumar, Pankaj [1 ]
Chaudhary, Sandeep [2 ]
机构
[1] Malaviya Natl Inst Technol Jaipur, Dept Civil Engn, Jaipur 302017, Rajasthan, India
[2] Indian Inst Technol Indore, Discipline Civil Engn, Indore 453552, Madhya Pradesh, India
关键词
Steel-concrete composite; Load-slip behavior; Strength; Slip; Initial and post-yield stiffness; Reinforcement amount; STEEL-CONCRETE COMPOSITE; SHEAR CONNECTORS; BEAMS; BEHAVIOR; TESTS;
D O I
10.1016/j.engstruct.2018.05.069
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of a composite connection lies in the adequate transfer of forces between the steel and concrete elements. The connection strategy adopted, determines the behavior of connection. This behavior of composite specimens connected using headed studs depends on various factors, such as, cross-sectional area and dimensions of shear connectors, material properties of connectors, grade of concrete, type of loads acting on the members and quantity and location of reinforcement in concrete slab. Current study addresses the effects of confinement of concrete by altering the quantity and location of reinforcement on composite connection. The behavior of connection was investigated in terms of connection bearing capacity, ductility and shear stiffness from load-slip curve. The shear stiffnesses of composite specimens were estimated through bilinear idealization of the obtained load-slip curves using energy balancing approach. The stiffness, strength and ductility of composite connections were found to increase with an increase in the percentage of reinforcement in the concrete layer. The distance between root of stud and first layer of reinforcement was found to be inversely related to strength and stiffness and directly related to ductility.
引用
收藏
页码:476 / 492
页数:17
相关论文
共 50 条
  • [21] EFFECT OF CONCRETE PLACEMENT ON SHEAR STRENGTH OF HEADED STUDS.
    Kuhn, John M.
    Buckner, C.Dale
    Journal of structural engineering New York, N.Y., 1986, 112 (08): : 1965 - 1971
  • [22] EFFECT OF CONCRETE PLACEMENT ON SHEAR-STRENGTH OF HEADED STUDS
    KUHN, JM
    BUCKNER, CD
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1986, 112 (08): : 1965 - 1971
  • [23] Performance of steel-ultrathin UHPC composite bridge deck based on ultra-short headed studs
    Wang, Li-Guo
    Shao, Xu-Dong
    Cao, Jun-Hui
    Chen, Yu-Bao
    He, Guang
    Wang, Yang
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2020, 54 (10): : 2027 - 2037
  • [24] Behaviour of demountable steel-concrete composite beams with bolts and headed studs
    Jakovljević, Isidora
    Spremić, Milan
    Fric, Nenad
    Marković, Zlatko
    ce/papers, 2023, 6 (3-4) : 84 - 89
  • [25] Shear behavior of short headed studs in Steel-ECC composite structure
    Guan, Yanhua
    Wu, Jiajie
    Sun, Renjuan
    Ge, Zhi
    Bi, Yufeng
    Zhu, Dengyuan
    ENGINEERING STRUCTURES, 2022, 250
  • [27] Influence of welding of headed studs on deflections of steel beams subjected to composite structures
    Kozuch, Maciej
    Skotny, Lukasz
    Lorenc, Wojciech
    Prace Naukowe Instytutu Budownictwa Politechniki Wroclawskiej, 2008, (90): : 107 - 114
  • [28] Seismic behaviour of double skin composite shear walls with overlapped headed studs
    Yan, Jia-Bao
    Li, Zhong-Xian
    Wang, Tao
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 191 : 590 - 607
  • [29] Shear resistance of headed shear studs welded on welded plates in composite floors
    Molkens, Tom
    Dobric, Jelena
    Rossi, Barbara
    ENGINEERING STRUCTURES, 2019, 197
  • [30] Performance evaluation of innovative triangular and spherical ribbed headed studs in composite steel beam-concrete slab junction
    Singh, Prakash Abhiram
    Patil, Yogesh Deoram
    Pardeshi, Rahul Tarachand
    STRUCTURES, 2024, 62