Detection of dental root fractures by using cone-beam computed tomography

被引:86
|
作者
Wang, P. [1 ,2 ]
Yan, X. B. [3 ,4 ]
Lui, D. G. [1 ,2 ]
Zhang, W. L. [1 ,2 ]
Zhang, Y. [1 ,2 ]
Ma, X. C. [1 ,2 ]
机构
[1] Peking Univ, Dept Oral & Maxillofacial Radiol, Sch Stomatol, Beijing 100081, Peoples R China
[2] Peking Univ, Dept Oral & Maxillofacial Radiol, Hosp Stomatol, Beijing 100081, Peoples R China
[3] Peking Univ, Stomatol Clin 1, Sch Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
[4] Peking Univ, Stomatol Clin 1, Hosp Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
关键词
cone-beam computed tomography; dental radiography; diagnosis; dental root fracture; TREATED TEETH; DIAGNOSIS; CT; RADIOGRAPHY;
D O I
10.1259/dmfr/84907460
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to compare the diagnostic accuracy of cone beam CT (CBCT) with that of conventional dental radiography in the detection of root fractures and to evaluate the influence of root canal fillings on root fracture detection. Methods: We investigated 128 patients with clinically suspected root fractures in 135 teeth. These patients underwent conventional dental radiography, CBCT and eventually surgical exploration. Among the 135 teeth, 86 were non-endodontically treated teeth and 49 were endodontically treated teeth. Two oral radiologists independently analysed the dental radiographs and CBCT images of each patient and reached a consensus. The CBCT findings of root fractures were set as the detection of a separation of the adjacent root segments on at least two contiguous sections and on at least two of the three-dimensional (3D) planes. Results: Root fracture was intraoperatively detected in 95 of the 135 teeth. The sensitivity and specificity of root fractures diagnosed on the basis of the consensus between the 2 evaluators were 26.3% and 100%, respectively, for dental radiography and 89.5% and 97.5%, respectively, for CBCT. CBCT was significantly more accurate than dental radiography in detecting root fractures (P < 0.001). The sensitivity of CBCT was reduced in the presence of root canal fillings but its specificity remained unaffected. Both the sensitivity and specificity of dental radiography were not influenced by the presence of root canal fillings. Conclusions: CBCT appears to be more accurate than conventional dental radiography in the detection of root fractures. Dentomaxillofacial Radiology (2011) 40, 290-298. doi: 10.1259/dmfr/84907460
引用
收藏
页码:290 / 298
页数:9
相关论文
共 50 条
  • [31] Applications of cone-beam computed tomography in fractures of the maxillofacial complex
    Shintaku, Werner H.
    Venturin, Jaqueline S.
    Azevedo, Bruno
    Noujeim, Marcel
    DENTAL TRAUMATOLOGY, 2009, 25 (04) : 358 - 366
  • [32] Postoperative Assessment of Incisor Dental Implants Using Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Nabeshima, Hiromitsu
    Hayashi, Hisashi
    Nakayama, Takehiko
    Kurita, Kenichi
    Ariji, Eiichiro
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (05) : 377 - 384
  • [33] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [34] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [35] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [36] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Aydin, Ulkem
    Gormez, Ozlem
    Yildirim, Derya
    ORAL RADIOLOGY, 2020, 36 (03) : 217 - 224
  • [37] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Ulkem Aydin
    Ozlem Gormez
    Derya Yildirim
    Oral Radiology, 2020, 36 : 217 - 224
  • [38] Clinical applications of cone-beam computed tomography in dental practice
    Scarfe, William C.
    Farman, Allan G.
    Sukovic, Predag
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2006, 72 (01): : 75 - 80
  • [39] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [40] Mandible Bone Osteoporosis Detection using Cone-beam Computed Tomography
    Abu Marar, Rasha F.
    Uliyan, Diaa M.
    Al-Sewadi, Hamza A.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2020, 10 (04) : 6027 - 6033