Experiment of X-ray source by 9.4 GHz X-band linac for nondestructive testing system

被引:0
|
作者
Natsui, Takuya [1 ]
Yamamoto, Tomohiko [1 ]
Sakamoto, Fumito [1 ]
Sakumi, Akira [1 ]
Dobashi, Katsuhiro [1 ]
Uesaka, Mitsuru [1 ]
Tanabe, Eiji [2 ]
Nakamura, Naoki [2 ]
Akemoto, Mitsuo [3 ]
Fukuda, Shigeki [3 ]
Higo, Toshiyasu [3 ]
Kudoh, Noboru [3 ]
Takatomi, Toshikazu [3 ]
Yoshida, Mitsuhiro [3 ]
机构
[1] Univ Tokyo, Nucl Profess Sch, Ibaraki, Japan
[2] AET Japan Inc, Kawasaki, Kanagawa, Japan
[3] KEK, Ibaraki, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing a compact X-ray source for Non-destructive Testing (NDT) system. We aim to develop a portable X-ray NDT system by 950keV X-band linac to realize on-site inspection. We use a low power (250kW) magnetron as RF source for compactness of whole system. By using low power magnetron, we can use small magnetron power supply and cooling system. Additionally, the system has X-band linac and it has small spot size of electron beam. Our final goal of X-ray spot size is less than 1mm. We have designed the linac structure of the pi mode at low energy parts and the pi/2 mode at high energy parts by using calculation codes. It was finished to measure resonant frequency and electromagnetic field of the linac. And the result of measurement consists with calculation data. The components of this system was completed and installed in the Nuclear Professional School, the University of Tokyo. We are carrying out electron beam accelerate testing.
引用
收藏
页码:2025 / +
页数:2
相关论文
共 50 条
  • [41] X-band magnicon amplifier experiment
    Gold, S.H.
    Fliflet, A.W.
    Nezhevenko, O.A.
    Yakovlev, V.P.
    Hirshfield, J.L.
    Kozyrev, E.V.
    Kinkead, A.K.
    IEEE International Conference on Plasma Science, 2000,
  • [42] Characterization of a radiographic system with broad energy band X-ray source
    Gambaccini, M.
    Cardarelli, P.
    Di Domenico, G.
    Taibi, A.
    Marziani, M.
    Barna, R. C.
    Auditore, L.
    Morgana, E.
    Loria, D.
    Trifiro, A.
    Trimarchi, M.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2011, 34 (01): : 37 - 47
  • [43] X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source
    Koerner, L. J.
    Philipp, H. T.
    Hromalik, M. S.
    Tate, M. W.
    Gruner, S. M.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [44] Nondestructive material testing using microfocus x-ray tubes
    Wichmann, M
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 456 - 456
  • [45] OVERVIEW OF X-RAY DIFFRACTION METHODS FOR NONDESTRUCTIVE TESTING.
    Azaroff, L.V.
    Sagamore Army Materials Research Conference Proceedings, 1979, : 1 - 19
  • [46] OPERATIONAL 150 KV MICROFOCUS ROD ANODE X-RAY SYSTEM FOR NONDESTRUCTIVE TESTING
    FONTIJN, LA
    PEUGEOT, RS
    NDT INTERNATIONAL, 1978, 11 (05): : 229 - 232
  • [47] Quantitative characterization of an x-ray source in an x-ray photoelectron spectroscopy system
    Pepper, SV
    Wheeler, DR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1509 - 1515
  • [48] Development of an X-ray photoelectron microscopic system with a compact X-ray source
    Fujikawa, C
    Yamaguchi, N
    Ohchi, T
    Hara, T
    Watanabe, K
    Tanaka, I
    Taguchi, M
    LASER AND PARTICLE BEAMS, 2002, 20 (01) : 39 - 42
  • [50] Development of x-ray photoelectron microscopic system with a compact x-ray source
    Fujikawa, C
    Yamaguchi, N
    Ohchi, T
    Ham, T
    Watanabe, K
    Tanaka, I
    Taguchi, M
    ECLIM 2000: 26TH EUROPEAN CONFERENCE ON LASER INTERACTION WITH MATTER, 2001, 4424 : 422 - 425