Logistic regression analysis and a risk prediction model of pneumothorax after CT-guided needle biopsy

被引:34
|
作者
Zhao, Yanfeng [1 ]
Wang, Xiaoyi [1 ]
Wang, Yong [2 ,3 ]
Zhu, Zheng [1 ]
机构
[1] Chinese Acad Med Sci, Dept Diagnost Radiol, Beijing 100021, Peoples R China
[2] Chinese Acad Med Sci, Natl Canc Ctr, Dept Ultrasound, Canc Hosp, Beijing 100021, Peoples R China
[3] Peking Union Med Coll, Beijing 100021, Peoples R China
关键词
Computed tomography; CT-guided needle biopsy; multivariate logistic regression analysis; pneumothorax; risk factor; CHEST TUBE PLACEMENT; SYSTEMIC AIR-EMBOLISM; LUNG-BIOPSY; DIAGNOSTIC-ACCURACY; RETROSPECTIVE ANALYSIS; COMPLICATION; LESIONS; MANAGEMENT; EFFICACY; SAFETY;
D O I
10.21037/jtd.2017.09.47
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Pneumothorax is the most common complication of computed tomography (CT)-guided needle biopsy. The purpose of this study was to investigate independent risk factors of pneumothorax, other than emphysema, after CT-guided needle biopsy and to establish a risk prediction model. Methods: A total of 864 cases of CT-guided needle biopsy with an 18-gauge cutting needle were enrolled in this study. The relevant risk factors associated with pneumothorax included age, sex, emphysema, shortaxis size of the lesion, depth of the lesion, body position, and the number of pleural punctures. Several independent risk factors of pneumothorax were found, and a predictive model for pneumothorax was established using univariate and multivariate logistic regression analyses. Results: Pneumothorax occurred in 31.4% (271/864) of cases. Univariate analysis showed that significant risk factors of pneumothorax included age, emphysema, small lesion size, no contact between the lesion and the pleura, prone or lateral body position, and multiple punctures. Independent risk factors of pneumothorax in the multivariate logistic regression analysis included emphysema (P = 0.000), no contact between the lesion and the pleura (P = 0.000), prone or lateral body position (P = 0.002), and the number of pleural punctures (P = 0.000). The sensitivity, specificity, and accuracy of the predictive model for pneumothorax were 56.8%, 79.6%, and 72.5%, respectively. Conclusions: Pneumothorax is a common complication of CT-guided lung biopsy. Independent risk factors of pneumothorax include emphysema, no contact between the lesion and the pleura, and prone or lateral body position. The predictive model developed in this study was highly accurate in predicting the incidence of pneumothorax.
引用
收藏
页码:4750 / 4757
页数:8
相关论文
共 50 条
  • [31] CT-GUIDED PERCUTANEOUS NEEDLE ASPIRATION BIOPSY
    VOCK, P
    RADIOLOGE, 1979, 19 (05): : 182 - 186
  • [32] Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
    M. F. Khan
    R. Straub
    S. R. Moghaddam
    A. Maataoui
    J. Gurung
    T. O. F. Wagner
    H. Ackermann
    A. Thalhammer
    T. J. Vogl
    V. Jacobi
    European Radiology, 2008, 18 : 1356 - 1363
  • [33] Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax
    Appel, Elisabeth
    Dommaraju, Sujithraj
    Camacho, Andres
    Nakhaei, Masoud
    Siewert, Bettina
    Ahmed, Muneeb
    Brook, Alexander
    Brook, Olga R.
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 6369 - 6375
  • [34] Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
    Khan, M. F.
    Straub, R.
    Moghaddam, S. R.
    Maataoui, A.
    Gurung, J.
    Wagner, T. O. F.
    Ackermann, H.
    Thalhammer, A.
    Vogl, T. J.
    Jacobi, V.
    EUROPEAN RADIOLOGY, 2008, 18 (07) : 1356 - 1363
  • [35] Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax
    Elisabeth Appel
    Sujithraj Dommaraju
    Andrés Camacho
    Masoud Nakhaei
    Bettina Siewert
    Muneeb Ahmed
    Alexander Brook
    Olga R. Brook
    European Radiology, 2020, 30 : 6369 - 6375
  • [36] Hemorrhage after CT-guided percutaneous needle biopsy: a case report
    Yang, Jing
    Kong, Weiliang
    Cao, Chao
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 11355 - 11356
  • [37] The pleural vent can be used in pneumothorax after CT-guided lung biopsy
    Bain, Lewis
    Permall, Kevin
    Reid, Philip
    Leitch, Andrew
    LUNG CANCER, 2021, 156 : S22 - S22
  • [38] Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung
    Nakamura, Megumi
    Yoshizako, Takeshi
    Koyama, Shingo
    Kitagaki, Hajime
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (05) : 474 - 478
  • [39] Influencing factors of pneumothorax and parenchymal haemorrhage after CT-guided transthoracic needle biopsy: single-institution experience
    Wattanasatesiri, Tunyarat
    Puntu, Warunyoo
    Vithitsuvanakul, Nophadol
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E379 - E388
  • [40] Frameless stereotactic CT-guided needle brain biopsy
    Adamo, F
    VETERINARY MEDICINE, 2004, 99 (10) : 844 - 846