Dentin Permeability and Nanoleakage of Universal Adhesives in Etch-and-rinse vs Self-etch Modes

被引:11
|
作者
Cruz, J. M. M. S. [1 ]
Silva, A. L. G. B. M. [2 ]
Eira, R. M. R. F. [2 ]
Sousa, B. M. P. R. [2 ]
Lopes, M. M. N. [1 ]
Cavalheiro, A. J. C. C. S. [2 ]
机构
[1] Univ Lisbon, Fac Dent Med, Lisbon, Portugal
[2] Univ Lisbon, Fac Dent Med, Dept Operat Dent, Lisbon, Portugal
关键词
MICROTENSILE BOND STRENGTH; IN-VITRO PERMEABILITY; SINGLE-STEP; RESIN; POLYMERIZATION; DEGRADATION; EXPRESSION; MEMBRANES; EFFICACY; OXALATE;
D O I
10.2341/19-276-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluates the reduction in dentin permeability (P) and the expression of nanoleakage in resin-dentin interfaces made with universal adhesives, comparing the self-etch mode of application with the etch-and-rinse mode of application. Methods and Materials: To measure dentin P at the baseline and after adhesive polymerization, 80 extracted noncarious human third molars (N=80) were sectioned to obtain 0.7-mm-thick midcoronal dentin disks. The specimens were randomly assigned to 8 groups according to the different adhesive systems and application modes used: Scotchbond Universal (SBU; etch-and-rinse [ER] mode vs self-etch [SE] mode), OptiBond XTR (OFT; etch-and-rinse mode vs self-etch mode), Clearfil Universal Bond Quick (CL; etch-and-rinse mode vs self-etch mode), and Adhese Universal (ADH; etch-and-rinse mode vs self-etch mode). A two-way analysis of variance with interaction was used to evaluate the P reduction differences among the groups (alpha=0.05). Sixteen additional 0.7-mm-thick dentin disks were similarly prepared and treated, immersed in 50 wt% ammoniacal silver nitrate, and then processed according to conventional methods for analysis under transmission electron microscopy. Results: The differences in P reduction among the adhesives were significant (p=0.029). For OPT and ADM (p=0.0304 and p=0.0120, respectively), the P reduction was higher in the ER mode than in the SE mode. For CL and SBU, no differences in P reduction was observed between the two application modes (p>0.05). All the groups showed some pattern of nanoleakage. Conclusions: No adhesive system completely reduced dentin P. Dentin sealing was higher for OPT and ADH in the ER mode, while for SBU and CL, there was no difference between the two modes. All the adhesive systems showed nanoleakage.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 50 条
  • [21] Early and 24-hour bond strength and degree of conversion of etch-and-rinse and self-etch adhesives
    Sadek, Fernanda Tranchesi
    Calheiros, Fernanda Calabro
    Cardoso, Paulo Eduardo Capel
    Kawano, Yoshio
    Tay, Franklin
    Ferrari, Marco
    AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (01): : 30 - 34
  • [22] Chitosan improves the durability of resin-dentin interface with etch-and-rinse or self-etch adhesive systems
    Paschoini, Vitoria Leite
    Ziotti, Isabella Rodrigues
    Neri, Claudio Roberto
    Milori Corona, Silmara Aparecida
    Souza-Gabriel, Aline Evangelista
    JOURNAL OF APPLIED ORAL SCIENCE, 2021, 29
  • [23] Influence of light-curing distance on degree of conversion and cytotoxicity of etch-and-rinse and self-etch adhesives
    Florian J. Wegehaupt
    Nancy Lunghi
    Georgios N. Belibasakis
    Thomas Attin
    BMC Oral Health, 17
  • [24] Influence of light-curing distance on degree of conversion and cytotoxicity of etch-and-rinse and self-etch adhesives
    Wegehaupt, Florian J.
    Lunghi, Nancy
    Belibasakis, Georgios N.
    Attin, Thomas
    BMC ORAL HEALTH, 2016, 17
  • [25] Shear bond strength to sound and caries-affected dentin of simplified "etch-and-rinse" and "self-etch" adhesives and the hybrid layer micromorphology
    Drobac, Milan
    Stojanac, Igor
    Ramic, Bojana
    Premovic, Milica
    Petrovic, Ljubomir
    VOJNOSANITETSKI PREGLED, 2019, 76 (07) : 675 - 683
  • [26] Are universal adhesives in etch-and-rinse mode better than old 2-step etch-and-rinse adhesives? One-year evaluation of bonding properties to dentin
    Wendlinger, M.
    Pomacondor-Hernandez, C.
    Pintado-Palomino, K.
    Cochinski, G. D.
    Loguercio, A. D.
    JOURNAL OF DENTISTRY, 2023, 132
  • [27] Microshear bond strength and interfacial morphology of etch-and-rinse and self-etch adhesive systems to superficial and deep dentin
    Yousry, Mai Mahmoud
    ElNaga, Albeer Abo
    Hafez, Randa M.
    El-Badrawy, Wafa
    QUINTESSENCE INTERNATIONAL, 2011, 42 (09): : E96 - E106
  • [28] Effect of tetracycline on the bond performance of etch-and-rinse adhesives to dentin
    Stanislawczuk, Rodrigo
    da Costa, Jully Anna
    Polli, Luceli Grabicoski
    Reis, Alessandra
    Loguercio, Alessandro Dourado
    BRAZILIAN ORAL RESEARCH, 2011, 25 (05): : 459 - 465
  • [29] Selective Enamel Etching Reconsidered: Better than Etch-and-Rinse and Self-etch?
    Frankenberger, Roland
    Lohbauer, Ulrich
    Roggendorf, Matthias J.
    Naumann, Michael
    Taschner, Michael
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (05): : 339 - 344
  • [30] Influence of atmospheric pressure variation combined with the presence of saltwater in adhesion to dentin of etch-and-rinse and self-etch systems
    Sardinha, Sara
    Lopes, Antonio
    Joao Mendes, J.
    ANNALS OF MEDICINE, 2018, 50 : S67 - S67