Dentin Permeability and Nanoleakage of Universal Adhesives in Etch-and-rinse vs Self-etch Modes

被引:11
|
作者
Cruz, J. M. M. S. [1 ]
Silva, A. L. G. B. M. [2 ]
Eira, R. M. R. F. [2 ]
Sousa, B. M. P. R. [2 ]
Lopes, M. M. N. [1 ]
Cavalheiro, A. J. C. C. S. [2 ]
机构
[1] Univ Lisbon, Fac Dent Med, Lisbon, Portugal
[2] Univ Lisbon, Fac Dent Med, Dept Operat Dent, Lisbon, Portugal
关键词
MICROTENSILE BOND STRENGTH; IN-VITRO PERMEABILITY; SINGLE-STEP; RESIN; POLYMERIZATION; DEGRADATION; EXPRESSION; MEMBRANES; EFFICACY; OXALATE;
D O I
10.2341/19-276-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluates the reduction in dentin permeability (P) and the expression of nanoleakage in resin-dentin interfaces made with universal adhesives, comparing the self-etch mode of application with the etch-and-rinse mode of application. Methods and Materials: To measure dentin P at the baseline and after adhesive polymerization, 80 extracted noncarious human third molars (N=80) were sectioned to obtain 0.7-mm-thick midcoronal dentin disks. The specimens were randomly assigned to 8 groups according to the different adhesive systems and application modes used: Scotchbond Universal (SBU; etch-and-rinse [ER] mode vs self-etch [SE] mode), OptiBond XTR (OFT; etch-and-rinse mode vs self-etch mode), Clearfil Universal Bond Quick (CL; etch-and-rinse mode vs self-etch mode), and Adhese Universal (ADH; etch-and-rinse mode vs self-etch mode). A two-way analysis of variance with interaction was used to evaluate the P reduction differences among the groups (alpha=0.05). Sixteen additional 0.7-mm-thick dentin disks were similarly prepared and treated, immersed in 50 wt% ammoniacal silver nitrate, and then processed according to conventional methods for analysis under transmission electron microscopy. Results: The differences in P reduction among the adhesives were significant (p=0.029). For OPT and ADM (p=0.0304 and p=0.0120, respectively), the P reduction was higher in the ER mode than in the SE mode. For CL and SBU, no differences in P reduction was observed between the two application modes (p>0.05). All the groups showed some pattern of nanoleakage. Conclusions: No adhesive system completely reduced dentin P. Dentin sealing was higher for OPT and ADH in the ER mode, while for SBU and CL, there was no difference between the two modes. All the adhesive systems showed nanoleakage.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 50 条
  • [1] Etch-and-rinse vs self-etch mode for dentin bonding effectiveness of universal adhesives
    Yamauchi, Kabun
    Tsujimoto, Akimasa
    Jurado, Carlos A.
    Shimatani, Yusuke
    Nagura, Yuko
    Takamizawa, Toshiki
    Barkmeier, Wayne W.
    Latta, Mark A.
    Miyazaki, Masashi
    JOURNAL OF ORAL SCIENCE, 2019, 61 (04) : 549 - 553
  • [2] Microtensile bond strength to dentin and enamel of self-etch vs. etch-and-rinse modes of universal adhesives
    Cruz, Joana
    Sousa, Bernardo
    Coito, Catarina
    Lopes, Manuela
    Vargas, Marcos
    Cavalheiro, Alexandre
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (04): : 174 - 182
  • [3] In vitro permeability of etch-and-rinse and self-etch adhesives used for immediate dentin sealing
    Sahin, Cem
    Cehreli, Zafer C.
    Yenigul, Muhittin
    Dayangac, Bulent
    DENTAL MATERIALS JOURNAL, 2012, 31 (03) : 401 - 408
  • [4] Effect of thermocycling on the durability of etch-and-rinse and self-etch adhesives on dentin
    Sangwichit, Ketkamon
    Kingkaew, Ruksaphon
    Pongprueksa, Pong
    Senawongse, Pisol
    DENTAL MATERIALS JOURNAL, 2016, 35 (03) : 360 - 368
  • [5] Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives: A Screening Study
    Froeb, Luisa
    Ruettermann, Stefan
    Romanos, Georgios E.
    Herrmann, Eva
    Gerhardt-Szep, Susanne
    MATERIALS, 2020, 13 (02)
  • [6] LONGEVITY OF SELF-ETCH DENTIN BONDING ADHESIVES COMPARED TO ETCH-AND-RINSE DENTIN BONDING ADHESIVES: A SYSTEMATIC REVIEW
    Masarwa, Nader
    Mohamed, Ahmed
    Abou-Rabii, Iyad
    Abu Zaghlan, Rawan
    Steier, Liviu
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2016, 16 (02) : 96 - 106
  • [7] Dimethyl Sulfoxide Dentin Pretreatments Do Not Improve Bonding of a Universal Adhesive in Etch-and-Rinse or Self-etch Modes
    Magalhaes de Mello, Rodrigo Mafra
    Roquim Alcantara, Barbara Albertini
    Gomes Franca, Fabiana Mantovani
    Botelho do Amaral, Flavia Lucisano
    Basting, Roberta Tarkany
    JOURNAL OF ADHESIVE DENTISTRY, 2022, 24 (01): : 49 - 56
  • [8] SEM-EDS nanoleakage evaluation of universal-adhesive-systems with etch-and-rinse and self-etch approach
    Certan, Mihai
    Polido, Maria
    Brito, Jose
    Azul, Ana Cristina
    ANNALS OF MEDICINE, 2019, 51 : S97 - S97
  • [9] Effects of Etch-and-Rinse and Self-etch Adhesives on Dentin MMP-2 and MMP-9
    Mazzoni, A.
    Scaffa, P.
    Carrilho, M.
    Tjaederhane, L.
    Di Lenarda, R.
    Polimeni, A.
    Tezvergil-Mutluay, A.
    Tay, F. R.
    Pashley, D. H.
    Breschi, L.
    JOURNAL OF DENTAL RESEARCH, 2013, 92 (01) : 82 - 86
  • [10] Bonding Performance of Universal Adhesives Applied to Nano-Hydroxyapatite Desensitized Dentin Using Etch-and-Rinse or Self-Etch Mode
    Meng, Yuchen
    Huang, Fan
    Wang, Silin
    Li, Meiwen
    Lu, Yi
    Pei, Dandan
    Li, Ang
    MATERIALS, 2021, 14 (16)