A study on Acoustic Characterization of Medical Ultrasound Transducers using pulse-echo methods

被引:0
|
作者
Pham, Khuong T. T. [1 ]
Nguyen, Nam L. [1 ]
机构
[1] Univ Danang, Danang Coll Technol, Dept Elect Engn, Danang, Vietnam
关键词
FEM; XTRANS; ultrasound; image; pulse-echo; piezoelectric;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The characterization of transducers ultimately play an important role in determining the quality of the image. Electrical impedance, pulse-length, bandwidth, and sensitivities are parameters commonly used to characterize the transducer. An achievement of this paper is that these parameters of two single transducers one element have been characterized by combining the measurement results in pulse-echo method with simulations to get more reliable, repeatable and consistent results. The simulations based on MATLAB codes (XTRANS) and COMSOL Multiphysics (Finite Element Model -FEM) are the most powerful and accurate tool available for this application to develop.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [1] ULTRASOUND TRANSDUCERS FOR PULSE-ECHO MEDICAL IMAGING
    HUNT, JW
    ARDITI, M
    FOSTER, FS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 453 - 481
  • [2] Fourier Spectrum Pulse-Echo for Acoustic Characterization
    Pal, Barnana
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2018, 37 (04)
  • [3] Fourier Spectrum Pulse-Echo for Acoustic Characterization
    Barnana Pal
    Journal of Nondestructive Evaluation, 2018, 37
  • [4] Ultrasound pulse-echo measurements on rough surfaces with linear array transducers
    Sjoj, Sidsel M. N.
    Blanco, Esther N.
    Wilhjelm, Jens E.
    Jensen, Henrik
    Hemmsen, Martin C.
    Jensen, Jorgen A.
    INTERNATIONAL CONGRESS ON ULTRASONICS (GDANSK 2011), 2012, 1433 : 211 - 214
  • [5] Attenuation Imaging with Pulse-Echo Ultrasound Based on an Acoustic Reflector
    Rau, Richard
    Unal, Ozan
    Schweizer, Dieter
    Vishnevskiy, Valery
    Goksel, Orcun
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT V, 2019, 11768 : 601 - 609
  • [6] An assessment of pulse-echo and hydrophone methods for characterising ultrasonic NDT transducers
    Zeqiri, B
    Hodnett, M
    Smith, RA
    Scudder, LP
    INSIGHT, 1998, 40 (01) : 20 - 27
  • [7] DISTORTION CHARACTERIZATION FOR NONNORMAL INCIDENCE IN PULSE-ECHO ULTRASOUND
    OROFINO, DP
    PEDERSEN, PC
    IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, 1989, : 1073 - 1076
  • [8] PULSE-ECHO SCATTERING IN SOLIDS WITH NONUNIFORM TRANSDUCERS
    STACEY, R
    WEIGHT, JP
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (05) : 363 - 368
  • [9] DIFFRACTION CORRECTION METHODS FOR PULSE-ECHO ACOUSTIC ATTENUATION ESTIMATION
    CESPEDES, I
    OPHIR, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07): : 707 - 717
  • [10] Comparison of Pulse-Echo Methods for Measuring Ultrasound Attenuation in the Liver
    Kim, H.
    Musack, R.
    Varghese, T.
    Kliewer, M.
    Jiang, J.
    Hall, T.
    Zagzebski, J.
    MEDICAL PHYSICS, 2008, 35 (06)