Evaluating Relaxation of High-strength Bolts by Parameters on Slip Faying Surfaces of Bolted Connections

被引:12
|
作者
Nah, Hwan-Seon [2 ]
Lee, Hyeon-Ju [2 ]
Kim, Kang-Seok [2 ]
Kim, Jin-Ho [3 ]
Kim, Woo-Bum [1 ]
机构
[1] Kongju Natl Univ, Architectural Engn Dept, Gongju, Cheungnam, South Korea
[2] Korea Elect Power Res Inst, Green Growth Lab, Taejon 305380, South Korea
[3] Res Inst Ind Sci & Technol, Architectural Res Dept, Hwaseong Si, Gyeonggi Do, South Korea
关键词
relaxation; faying surface; bolts; coating; slip coefficient;
D O I
10.1007/BF03215838
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The clamping force of a high-strength bolt reduces within a certain time period after the initial clamping force. When special treatments are used on a faying surface, the clamping force is relaxed severely. Tests were conducted for slip critical joints subjected to various faying surface parameters. Relaxation occurred for slip resistant joints with an uncoated surface that had been shot-blasted, cleaned, milled or rusted. It was observed that the initial clamping force dropped from 6.2% to 8.0% after 744 hours. For joints with a 5 mil thick zinc coating, the clamping force of the bolts decreased by 8.37%, and in the case of 4.9 mil thick red lead painted treatment, the relaxation ratio was 24.6%. The standard deviation of the slip coefficients between the time immediately after tightening and 1,000 hours after tightening was 0.223. It is particularly noteworthy that, for red lead painted treatment, the slip coefficient dropped from 2.5 times to 2.8 times when compared with the slip coefficient before relaxation. Joints with inorganic zinc should not have thickness exceeding 5 mils, and joints with a red lead painted surface should not be allowed regardless of the thickness of coating.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 50 条
  • [21] STUDY ON HIGH-STRENGTH BOLTED END PLATE CONNECTIONS
    ASAI, O
    TSUKUI, K
    KAWAMO, K
    NAKAYAMA, T
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1980, 23 (184): : 1712 - 1712
  • [22] Simplified numerical model for high-strength bolted connections
    Zhao, Zhongwei
    Liang, Bing
    Liu, Haiqing
    Li, Yongjing
    ENGINEERING STRUCTURES, 2018, 164 : 119 - 127
  • [23] Experimental Study on the Slip Behaviour of Stainless Steel High-Strength Bolted Connections with a New Surface Treatment
    Zhang, Tianxiong
    Bu, Yidu
    Wang, Yuanqing
    Chen, Zhihua
    He, Wei
    MATERIALS, 2022, 15 (16)
  • [24] High-strength bolts
    Kulak, Geoffrey L.
    Modern Steel Construction, 1995, 35 (03): : 42 - 47
  • [25] ANALYSIS OF HIGH-STRENGTH BOLTED END PLATE CONNECTIONS.
    Agerskov, Henning
    Bygningsstatiske Meddelelser, 1977, 48 (03): : 63 - 93
  • [26] Strength of Bolted Lap Shear Connections with Advanced High-Strength Steel Sheets
    Ding, Chu
    Xia, Yu
    Li, Zhanjie
    Blum, Hannah B.
    Schafer, Benjamin W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (01)
  • [27] Corrosion effects on the fatigue performance of high-strength bolted friction connections
    Jiang, Chao
    Xiong, Wen
    Cai, C. S.
    Zhou, Xiaoyi
    Zhu, Yanjie
    INTERNATIONAL JOURNAL OF FATIGUE, 2023, 168
  • [28] Fracture behavior of high-strength bolted steel connections at elevated temperatures
    Cai, Wen-Yu
    Jiang, Jian
    Li, Guo-Qiang
    Wang, Yan-Bo
    ENGINEERING STRUCTURES, 2021, 245
  • [29] TESTS ON HIGH-STRENGTH BOLTED T-STUB CONNECTIONS.
    Agerskov, Henning
    Denmark, Technical University, Structural Research Laboratory, Report, 1979, (106):
  • [30] Fretting fatigue phenomenon in bolted high-strength steel plate connections
    Hamalainen, Olli-Pekka
    Bjork, Timo
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2015, 8 (03): : 174 - +