MnO2 nanoparticle mediated colorimetric turn-off determination of ascorbic acid

被引:20
|
作者
Wang, Qi [1 ]
Ma, Xulu [1 ]
Lv, Houhua [1 ]
Wei, Awen [1 ]
Wu, Tingxuan [1 ]
Ding, Lifeng [1 ]
Ma, Xiang [1 ]
Ma, Chunlei [1 ]
机构
[1] Taiyuan Inst Technol, Chem & Chem Engn Dept, Taiyuan 030008, Shanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
VITAMIN-C; PERFORMANCE; PEROXIDASE; STRATEGY;
D O I
10.1039/c9nj05751j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ascorbic acid (AA) is an esstential micronutrient in the human body and participates in vital processes. It can only be supplemented by external intake, making the determination of AA in food or beverages of significance. In the present work, MnO2 nanoparticle (MnO2 NP) based turn-off colorimetry was established for AA determination on the basis of AA-stimulated inhibition of catalytic oxidation. MnO2 NPs were synthesized through a biotemplating method and displayed effective catalytic oxidation activity for oxidation of TMB, triggering a chromogenic reaction. Interestingly, the introduction of AA induced the decomposition of MnO2 NPs and as a consequence decreased the colour. Therefore, sensitive and selective turn-off colorimetry for AA detection was established and a satisfactory linear range of 0.5-30 mu M with a detection limit of 0.28 mu M was obtained. This MnO2 NP-based method was activated via a novel sensing principle, complementing and facilitating colorimetry for AA.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [31] DETERMINATION OF MNO AND MNO2 IN MANGANESE ORES
    RYLKOVA, AS
    CHEREVIK, VV
    SAMBORSKAYA, LE
    INDUSTRIAL LABORATORY, 1986, 52 (08): : 707 - 709
  • [32] DETERMINATION OF ASCORBIC ACID BY A NEW COLORIMETRIC REACTION
    SCHMALL, M
    PIFER, CW
    WOLLISH, EG
    ANALYTICAL CHEMISTRY, 1953, 25 (10) : 1486 - 1490
  • [33] DETERMINATION OF ASCORBIC ACID BY A NEW COLORIMETRIC REACTION
    SCHMALL, M
    PIFER, CW
    WOLLISH, EG
    ANALYTICAL CHEMISTRY, 1953, 25 (03) : 517 - 517
  • [34] Amperometric sensor for L-ascorbic acid determination based on MnO2 bulk modified screen printed electrode
    Turkusic, E
    Milicevic, V
    Tahmiscija, H
    Vehabovic, M
    Basic, S
    Amidzic, V
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05): : 466 - 470
  • [35] Amperometric sensor for L-ascorbic acid determination based on MnO2 bulk modified screen printed electrode
    E. Turkusic
    V. Milicevic
    H. Tahmiscija
    M. Vehabovic
    S. Basic
    V. Amidzic
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 466 - 470
  • [36] The fabrication of MnO2 nanoparticle for supercapacitor application
    Kang, Dequn
    Chen, Zexiang
    Hu, Tianyong
    Dong, Miao
    Ren, Jun
    MATERIALS, MECHANICAL ENGINEERING AND MANUFACTURE, PTS 1-3, 2013, 268-270 : 164 - 167
  • [37] N-Doped Carbon Dots as Fluorescent "Turn-Off" Nanosensors for Ascorbic Acid and Fe3+ Detection
    Cui, Jingjing
    Zhu, Xiaoxuan
    Liu, Yanping
    Liang, Liman
    Peng, Youshun
    Wu, Songgu
    Zhao, Yan
    ACS APPLIED NANO MATERIALS, 2022, 5 (05) : 7268 - 7277
  • [38] Visual and Colorimetric Detection of Cyanide Anion Based on a "Turn-off" Daylight Fluorescent Molecule
    Jiao, Lijuan
    Liu, Mingming
    Zhang, Min
    Yu, Changjiang
    Wang, Zhaoyun
    Hao, Erhong
    CHEMISTRY LETTERS, 2011, 40 (06) : 623 - 625
  • [39] Synthesis of MnO2 sub-microspheres with effective oxidase-mimicking nanozymes for the colorimetric assay of ascorbic acid in orange fruits and juice
    Isho, Ramya D.
    Mohammad, Nidhal Sher M.
    Omer, Khalid M.
    NEW JOURNAL OF CHEMISTRY, 2023, 47 (16) : 7800 - 7809
  • [40] A novel fluorescent "Turn-Off/Turn-On" system for the detection of acid phosphatase activity
    Guo, Pu
    Yan, Shengyong
    Zhou, Yimin
    Wang, Changcheng
    Xu, Xiaowei
    Weng, Xiaocheng
    Zhou, Xiang
    ANALYST, 2013, 138 (12) : 3365 - 3367