Digital Non-Linearity Calibration for ADCs With Redundancy Using a New LUT Approach

被引:6
|
作者
Gines, Antonio [1 ]
Leger, Gildas [1 ]
Peralias, Eduardo [1 ]
机构
[1] Univ Seville, Inst Microelect Sevilla IMSE CNM, Seville 41092, Spain
关键词
Calibration; Table lookup; Redundancy; Transfer functions; Pipelines; Estimation; Additives; Pipeline and SAR ADCs; redundancy; LUT-based calibration; integral-non-linearity (INL); PIPELINE ADC; SAR ADC; ERRORS; CODE;
D O I
10.1109/TCSI.2021.3066886
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel Look-up Table (LUT) calibration technique for static non-linearity compensation in analog-to-digital converters (ADCs) with digital redundancy, such as Successive Approximation Register (SAR), Algorithmic, Sub-ranging or Pipeline ADCs. The method compensates the performance limitations of the conventional LUT approach in presence of comparison noise and/or non-monotonicity. In these circumstances, the input-output transfer function of a redundant ADC becomes significantly multivalued - that is, different output codes can be achieved for the same input level at different time instants. This behavior is motivated because from sample to sample, in a design with redundancy, the processing signal path is not unique, causing that the error under calibration becomes time-dependent, something which is not contemplated in the conventional calibration model. To deal with this effect, this work proposes a digital low-cost post-processing of the standardized Integral-Non-linearity (INL), which resolves multivalued situations using a direct access to the internal redundant codes. The method improvements are validated by realistic SAR and Pipeline ADC case studies at behavioral level, and by experimental data from an 11-bit 60Msps Pipeline ADC implemented in a 130nm CMOS process. These experimental results show that the proposed calibration achieves an improvement of approximately 1.6 effective bits at full-scale input amplitude.
引用
收藏
页码:3197 / 3210
页数:14
相关论文
共 50 条
  • [41] Detection of Non-Linearity in Schizophrenic Patients Using Magnetoencephalography
    A. Kotini
    P. Anninos
    Brain Topography, 2002, 15 : 107 - 113
  • [42] A Non-linearity Correction Method for Calibration of Optical Sensor at Low Level Light
    Wang, Zilu
    Wu, Bin
    Sergienko, Tima
    ASIASIM 2012, PT I, 2012, 323 : 126 - +
  • [43] Effects of Calibration Factors and Intensity Dependent Non-linearity on Functional Photoacoustic Microscopy
    Danielli, Amos
    Yao, Junjie
    Krumholz, Arie
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [44] Calibration of non-linearity of piezo elements and image distortion in atomic force microscope
    Zhang, HJ
    Zhang, DX
    Zhang, H
    Lin, XF
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2002, : 25 - 28
  • [45] A Deep Learning Approach to Non-linearity in Wearable Stretch Sensors
    Oldfrey, Ben
    Jackson, Richard
    Smitham, Peter
    Miodownik, Mark
    FRONTIERS IN ROBOTICS AND AI, 2019, 6
  • [46] Adaptive fuzzy approach for non-linearity compensation in MEMS gyroscope
    Juan, Wanru
    Fei, Juntao
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2013, 35 (08) : 1008 - 1015
  • [47] Bank Profitability and Efficiency in Portugal and Spain: A Non-Linearity Approach
    Neves, Maria Elisabete
    Proenca, Catarina
    Dias, Antonio
    JOURNAL OF RISK AND FINANCIAL MANAGEMENT, 2020, 13 (11)
  • [48] DETECTION OF OUTLIERS AND OF NON-LINEARITY IN THE EVALUATION OF CALIBRATION DATA BY LINEAR-REGRESSION
    HUBER, W
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 319 (04): : 379 - 383
  • [49] Non-linearity tests with digital recorder used for impulse voltage measurements
    Sato, Shuji
    Harigai, Masato
    Nishimura, Seisuke
    Yamaguchi, Tomohisa
    IEEJ Transactions on Fundamentals and Materials, 2009, 129 (07) : 470 - 476
  • [50] Heat transfer in fixed bed:: a model non-linearity approach
    Thoméo, JC
    Freire, JT
    CHEMICAL ENGINEERING SCIENCE, 2000, 55 (12) : 2329 - 2338