Bioelectrical impedance analysis in the clinical management of preeclamptic women with edema

被引:30
|
作者
Yasuda, R [1 ]
Takeuchi, K [1 ]
Funakoshi, T [1 ]
Maruo, T [1 ]
机构
[1] Kobe Univ, Dept Obstet & Gynecol, Grad Sch Med, Chuo Ku, Kobe, Hyogo 6500017, Japan
关键词
preeclampsia; edema; bioelectrical impedance analysis;
D O I
10.1515/JPM.2003.038
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The aim of this study was to correlate bioelectrical impedance analysis (BIA) with the clinical course of preeclampsia with edema. Design: 440 pregnant women with apparently normal, single pregnancy participated in this longitudinal study. Anthropometric measurements and BIA were performed during pregnancy and postpartum period. Results: All of the measurements were completed in 333 of the women; 279 of the women had a normal pregnancy (control group). The remaining 54 women developed edema during the third trimester of pregnancy. Of these, 40 women had only edema, and 14 women had edema followed by hypertension and/or proteinuria (preeclampsia group).The BIA index (the height squared divided by resistance) in the control group increased significantly towards late pregnancy, compared to that in early pregnancy. The indexes in the edema group were significantly higher during the third trimester compared to those of the control group at the same gestational week. The index in the preeclampsia group was higher relative to that in the control group. Moreover, a substantial increase in the index preceded the development of edema in the cases in which pregnancy was terminated due to deterioration of preeclampsia. Conclusions: Our results show that BIA is a useful method for monitoring longitudinal changes in total body water in pregnant women, and that BIA may be a powerful predictor of deterioration of preeclampsia preceded by edema.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 50 条
  • [21] Segmental bioelectrical impedance analysis
    De Lorenzo, A
    Andreoli, A
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2003, 6 (05): : 551 - 555
  • [22] BIOELECTRICAL IMPEDANCE IN CLINICAL-PRACTICE
    ZAROWITZ, BJ
    PILLA, AM
    DICP-THE ANNALS OF PHARMACOTHERAPY, 1989, 23 (7-8): : 548 - 555
  • [23] Comparison of bioelectrical impedance analysis in healthy pregnant women and patient on hemodialysis
    Hashimoto, Seiji
    Maoka, Tomochika
    Yamamoto, Rie
    Kawashima, Keisuke
    Nishikawa, Akira
    Sakurada, Katsumi
    Koike, Takao
    Shigematsu, Takashi
    THERAPEUTIC APHERESIS AND DIALYSIS, 2021, 25 (02) : 160 - 165
  • [24] Bioelectrical impedance analysis revisited
    Mikes, DM
    Cha, BA
    Dym, CL
    Baumgaertner, J
    Hartzog, AG
    Tacey, AD
    Calabria, MR
    LYMPHOLOGY, 1999, 32 (04) : 157 - 165
  • [25] Bioelectrical phase angle and impedance vector analysis - Clinical relevance and applicability of impedance parameters
    Norman, Kristina
    Stobaus, Nicole
    Pirlich, Matthias
    Bosy-Westphal, Anja
    CLINICAL NUTRITION, 2012, 31 (06) : 854 - 861
  • [26] Bioelectrical impedance analysis revisited
    Cornish, BH
    LYMPHOLOGY, 2000, 33 (03) : 136 - 137
  • [27] Edema index measured by bioelectrical impedance analysis as a predictor of fluid reduction needed to remove clinical congestion in acute heart failure
    Yamazoe, Masahiro
    Mizuno, Atsushi
    Niwa, Koichiro
    Isobe, Mitsuaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 190 - 192
  • [28] Impedance vector distribution by body mass index and conventional bioelectrical impedance analysis in obese women
    Guida, B
    Trio, R
    Pecoraro, P
    Gerardi, MC
    Laccetti, R
    Nastasi, A
    Falconi, C
    NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2003, 13 (02) : 72 - 79
  • [29] Analysis of concordance between the bioelectrical impedance vector analysis and the bioelectrical impedance spectroscopy in haemodialysis patients
    Teruel-Briones, Jose L.
    Fernandez-Lucas, Milagros
    Ruiz-Roso, Gloria
    Sanchez-Ramirez, Humberto
    Rivera-Gorrin, Maite
    Gomis-Couto, Antonio
    Rodriguez-Mendiola, Nuria
    Quereda, Carlos
    NEFROLOGIA, 2012, 32 (03): : 389 - 395
  • [30] A bioelectrical impedance analysis device for improved management of congestive heart failure
    Edwardson, M
    Talaie, V
    Clark, C
    Antinoro, R
    Risse, A
    Gonzalez, J
    Weisberger, C
    Feldman, CL
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 9 - 12