Thermal insulation performance of an advanced photovoltaic vacuum glazing: A numerical investigation and simulation

被引:13
|
作者
Chen, Benyuan [1 ,2 ]
Lv, Hui [1 ,2 ]
Liao, Jun [1 ,2 ]
Dong, Shijie [1 ]
Cheng, Chunfu [1 ,2 ]
Lv, Qinghua [1 ,2 ]
Li, Jin [1 ,2 ]
Su, Yuehong [3 ]
Riffat, Saffa [3 ]
机构
[1] Hubei Univ Technol, Hubei Collaborat Innovat Ctr High Efficiency Util, Wuhan 430068, Hubei, Peoples R China
[2] Hubei Univ Technol, Sch Sci, Wuhan 430068, Hubei, Peoples R China
[3] Univ Nottingham, Dept Architecture & Built Environm, Nottingham NG7 2RD, England
基金
对外科技合作项目(国际科技项目);
关键词
SOLAR GLASS; EFFICIENCY; CELLS;
D O I
10.1063/1.5055363
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Structural details of an advanced laminated PV (photovoltaic) vacuum glazing are illustrated. The glazing design features low heat gain or loss, while the sandwiched PV film generates electricity and allows daylight and vision. The thin vacuum gap and glass sheets make it slimmer and lighter than conventional designs. Aerogel support pillars and epoxy resin edge seals minimise conductive heat transfer and further reduce the weight of the window. The thermal insulation performance of the PV vacuum glazing is numerically investigated. All the three heat transfer mechanisms are considered in the COMSOL modelling. During the modelling of radiation in participating media, the optical properties of low-e (low-emissivity) and PV coating are considered and a boundary condition for translucence is re-customized in particular. For the verification of the modeling accuracy, a simplified vacuum glazing model is adopted first. The simulation results are consistent with the thermal performance data report of a vacuum glazing manufacturer. Subsequently, comprehensive simulation results with different configurations of the PV vacuum glazing are presented and discussed. Retrofitting of steel pillars with aerogel pillars for conventional vacuum glazing can yield a decrease of 0.3255W/m(2)K in the overall U-value and a decrease of 0.2559W/m(2)K in the central U-value. Besides, the thermal resistances of the laminated structure are calculated layer by layer. Moreover, the influence of the radiative parameters of the PV film on the thermal performance of the glazing is assessed. On the other hand, the simulation of the PV vacuum glazing under solar radiation is carried out to evaluate its working temperature. Published under license by AIP Publishing.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Numerical heat transfer modeling and climate adaptation analysis of vacuum-photovoltaic glazing
    Tan, Yutong
    Peng, Jinqing
    Luo, Yimo
    Luo, Zhengyi
    Curcija, Charlie
    Fang, Yueping
    APPLIED ENERGY, 2022, 312
  • [32] Numerical Investigation and Experimental Verification of the Thermal Bridge Effect of Vacuum Insulation Panels with Various Cavities
    Huang, Chao
    Kan, Ankang
    Chen, Zhaofeng
    Yang, Chao
    Zhang, Yuan
    Yang, Lixia
    ENERGIES, 2025, 18 (03)
  • [33] Experimental measurement and numerical simulation of the thermal performance of a double glazing system with an interstitial Venetian blind
    Sun, Yanyi
    Wu, Yupeng
    Wilson, Robin
    Lu, Sixu
    BUILDING AND ENVIRONMENT, 2016, 103 : 111 - 122
  • [34] Effect of nano vacuum insulation panel and nanogel glazing on the energy performance of office building
    Mujeebu, Muhammad Abdul
    Ashraf, Noman
    Alsuwayigh, H.
    APPLIED ENERGY, 2016, 173 : 141 - 151
  • [35] Numerical Investigation of Thermal Performance of a Trombe Wall of a New Design with Glazing for Cold Climatic Conditions
    S. A. Kostikov
    M. S. Grinkrug
    S. A. Gordin
    J. Yiqiang
    Thermal Engineering, 2023, 70 : 1041 - 1050
  • [36] Numerical Investigation of Thermal Performance of a Trombe Wall of a New Design with Glazing for Cold Climatic Conditions
    Kostikov, S. A.
    Grinkrug, M. S.
    Gordin, S. A.
    Yiqiang, J.
    THERMAL ENGINEERING, 2023, 70 (12) : 1041 - 1050
  • [37] Numerical Simulation of Electric-Thermal Performance of A Solar Concentrating Photovoltaic/Thermal System
    Sun Jian
    Shi Mingheng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 672 - +
  • [38] Numerical simulation and performance investigation of an advanced adsorption desalination cycle
    Thu, Kyaw
    Chakraborty, Anuthosh
    Kim, Young-Deuk
    Myat, Aung
    Saha, Bidyut Baran
    Ng, Kim Choon
    DESALINATION, 2013, 308 : 209 - 218
  • [39] Influence of insulation defects on the thermal performance of walls. An experimental and numerical investigation
    Nardi, Iole
    Perilli, Stefano
    de Rubeis, Tullio
    Sfarra, Stefano
    Ambrosini, Dario
    JOURNAL OF BUILDING ENGINEERING, 2019, 21 : 355 - 365
  • [40] Numerical investigation on thermal insulation effect by coolant layer in performance of transpiration cooling
    Bian, Yuyang
    Liu, Xue
    Zheng, Jiayue
    Diao, Yanqi
    Zhou, Weixing
    Yanovskiy, Leonid
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 214