A comparison of higher order aberrations following implantation of four foldable Intraocular lens designs

被引:0
|
作者
Martin, RG
Sanders, DR
机构
[1] Clin Res Ctr, Elmhurst, IL 60126 USA
[2] Carolina Eye Associates, Southern Pines, NC USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the higher order aberrations following implantation of four foldable intraocular lens (IOL) designs. METHODS: One hundred twenty-two eyes were randomly assigned to undergo implantation with one of four foldable IOL designs-Collamer (STAAR Surgical, Monrovia, Calif), plate haptic silicone (STAAR Surgical), AcrySof (Alcon, Ft Worth, Tex), or the Sensar (Advanced Medical Optics, Santa Ana, Calif). All enrolled eyes underwent wavefront assessment using the Tracey Visual Function Analyzer (Tracey Technologies, Houston, Tex). RESULTS: Preoperatively, no significant differences were noted in higher order aberrations between the four lens groups. No significant differences were noted among the plate haptic silicone, Sensar, or Acrysof lenses at 1 week or 1 month postoperatively, or among the Collamer, plate haptic silicone, or Sensar lenses, with regard to total higher order aberrations, although differences were observed in individual aberration terms. At 1 week and 1 month postoperatively, the Collamer IOL had significantly less higher order aberrations than the Acrysof lens (P<.01). Significantly less third and fourth order aberrations, coma, trefoil, spherical aberration, and tetrafoil were observed postoperatively with the Collamer than the Acrysof IOL. There were no parameters where the AcrySof had significantly less optical aberrations than the Collamer. CONCLUSIONS: The Collamer IOL design is associated with fewer higher order aberrations than the AcrySof lens.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 50 条
  • [31] Comparison of higher order wavefront aberrations with four aberrometers
    Cook, William H.
    McKelvie, James
    Wallace, Henry B.
    Misra, Stuti L.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1030 - 1035
  • [32] Visual and refractive outcome, higher order aberrations and complications following intraocular lens exchange in eyes without comorbidities
    Nikola Henningsen
    Ramin Khoramnia
    Gerd U. Auffarth
    Maximilian K. Köppe
    Grzegorz Łabuz
    Timur M. Yildirim
    Scientific Reports, 15 (1)
  • [33] Incision width after phacoemulsification with foldable intraocular lens implantation
    Mamalis, N
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02): : 237 - 241
  • [34] Foldable iris-fixated intraocular lens implantation in children
    Ryan, Andrea
    Hartnett, Claire
    Lanigan, Bernadette
    O'Keefe, Michael
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e458 - e462
  • [35] Longterm results after phacovitrectomy and foldable intraocular lens implantation
    Li, Wensheng
    Sun, Gang
    Wu, Ronghan
    Wang, Xindan
    Xu, Ming
    Sun, Changwen
    ACTA OPHTHALMOLOGICA, 2009, 87 (08) : 896 - 900
  • [36] Prewound assisted technique for hydrophobic foldable intraocular lens implantation
    Shiba, Takuya
    Tsuneoka, Hiroshi
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 569 - 572
  • [37] Descemet Membrane Detachment During Foldable Intraocular Lens Implantation
    Mannan, Rashim
    Pruthi, Archna
    Parkash, Rohit Om
    Jhanji, Vishal
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (02): : 106 - 108
  • [38] Implantation of a foldable Collamer lens as a posterior chamber phakic intraocular lens in myopia
    Roy, S
    Tritten, JJ
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (04) : 196 - 200
  • [39] Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses
    S W Kim
    H Ahn
    E K Kim
    T-i Kim
    Eye, 2008, 22 : 1493 - 1498
  • [40] Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses
    Kim, S. W.
    Ahn, H.
    Kim, E. K.
    Kim, T-i
    EYE, 2008, 22 (12) : 1493 - 1498