PURPOSE: To determine the higher order aberrations following implantation of four foldable intraocular lens (IOL) designs. METHODS: One hundred twenty-two eyes were randomly assigned to undergo implantation with one of four foldable IOL designs-Collamer (STAAR Surgical, Monrovia, Calif), plate haptic silicone (STAAR Surgical), AcrySof (Alcon, Ft Worth, Tex), or the Sensar (Advanced Medical Optics, Santa Ana, Calif). All enrolled eyes underwent wavefront assessment using the Tracey Visual Function Analyzer (Tracey Technologies, Houston, Tex). RESULTS: Preoperatively, no significant differences were noted in higher order aberrations between the four lens groups. No significant differences were noted among the plate haptic silicone, Sensar, or Acrysof lenses at 1 week or 1 month postoperatively, or among the Collamer, plate haptic silicone, or Sensar lenses, with regard to total higher order aberrations, although differences were observed in individual aberration terms. At 1 week and 1 month postoperatively, the Collamer IOL had significantly less higher order aberrations than the Acrysof lens (P<.01). Significantly less third and fourth order aberrations, coma, trefoil, spherical aberration, and tetrafoil were observed postoperatively with the Collamer than the Acrysof IOL. There were no parameters where the AcrySof had significantly less optical aberrations than the Collamer. CONCLUSIONS: The Collamer IOL design is associated with fewer higher order aberrations than the AcrySof lens.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 50 条
  • [1] Implantation of a Small Aperture Intraocular Lens in Eyes with Irregular Corneas and Higher Order Aberrations
    Franco, Fabrizio
    Branchetti, Marco
    Vicchio, Lidia
    Serino, Federica
    Piergentili, Marco
    Spagnuolo, Vito
    Santoro, Francesca
    Virgili, Gianni
    Giansanti, Fabrizio
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (03) : 317 - 323
  • [2] Higher-order Aberrations after Posterior Chamber Phakic Intraocular lens Implantation
    Liu, Hongting
    Li, Jing
    Agbedia, Owhofasa
    Wang, Jiangxia
    Li, Xinyu
    Wang, Hujie
    Liu, Lei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Implantation of a foldable intraocular lens in dogs
    Gaiddon, JA
    Lallement, PE
    Peiffer, RL
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2000, 216 (06) : 875 - +
  • [4] Higher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses
    Tahzib, Nayyirih G.
    MacRae, Scott M.
    Yoon, Geunyoung
    Berendschot, Tos T. J. M.
    Eggink, Fred A. G. J.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1913 - 1920
  • [5] Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations
    Young Min Park
    Bong Joon Choi
    Jong Soo Lee
    International Journal of Ophthalmology, 2016, (12) : 1785 - 1789
  • [6] Changes of higher order aberrations and contrast sensitivity after implantation of artisan phakic intraocular lens
    Lee, SJ
    Chung, SH
    Seo, KY
    Lee, HK
    Park, JW
    Kim, EK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] The Influence of Decentration on Higher-Order Aberrations in Artisan Aphakic Intraocular Lens Implantation Eyes
    Miao, Aizhu
    Zhang, Min
    Chen, Tianhui
    Lu, Yi
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [8] Changes in higher order aberrations and contrast sensitivity after implantation of a phakic Artisan intraocular lens
    Chung, So-Hyang
    Lee, Seung Jae
    Lee, Hyung Keun
    Seo, Kyoung Yul
    Kim, Eung Kweon
    OPHTHALMOLOGICA, 2007, 221 (03) : 167 - 172
  • [9] Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations
    Park, Young Min
    Choi, Bong Joon
    Lee, Jong Soo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (12) : 1785 - 1789
  • [10] Optimizing higher-order aberrations with intraocular lens technology
    Bellucci, Roberto
    Morselli, Simonetta
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 67 - 73