Brittle failure in RC masonry infilled frames: The role of infill overstrength

被引:37
|
作者
Blasi, Gianni [1 ,2 ]
De Luca, Flavia [1 ]
Aiello, Maria Antonietta [2 ]
机构
[1] Univ Bristol, Dept Civil Engn, Queens Bldg, Bristol BS8 1TR, Avon, England
[2] Univ Salento, Dept Innovat Engn, Via Monteroni, I-73100 Lecce, Italy
关键词
Masonry infilled reinforced concrete frame; Experimental tests; Equivalent strut model; Shear failure; Infill overstrength; REINFORCED-CONCRETE FRAMES; BEAM-COLUMN JOINTS; SEISMIC RESPONSE; NONLINEAR BEHAVIOR; R/C FRAMES; BUILDINGS; EARTHQUAKE; MODEL; FRAGILITY; CAPACITY;
D O I
10.1016/j.engstruct.2018.09.079
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The interaction between an infill panel and a reinforced concrete (RC) column can lead to the brittle failure of the structural element. A novel combination of cutting-edge analytical modelling approaches for masonry infills and RC elements is employed to simulate five experimental tests (three infilled and two bare) characterized by brittle failure modes. The infill is modelled with a multi-strut idealisation, and the RC column is modelled using the recently developed PinchingLimitStateMaterial in OpenSees. The effects of the infill type (solid or hollow) and ductility characteristics of the RC elements on the optimal modelling parameters are investigated. The focus of this study is on the assumption of the overstrength ratio between the maximum and cracking strengths of the panel when brittle failure occurs. The preliminary assumption for this parameter is the widely accepted value of 1.3 suggested in the formulation by Panagiotakos and Fardis. This value is found to influence the shear failure simulation. To more accurately predict brittle failure, higher overstrength values of the infill are used in the numerical model to improve the matching between the numerical and experimental tests. These values are then compared with the approximate estimation of the overstrength ratio from a database of 98 experimental tests. The suggested estimation of the overstrength ratio is systematically greater than 1.3 and dependent on the infill type (i.e., 1.44 for hollow and 1.55 for solid infills). The proposed values can have a high impact on future code compliant recommendations aimed at verifying the likelihood of the occurrence of brittle failure in columns due to their interaction with infill panels.
引用
收藏
页码:506 / 518
页数:13
相关论文
共 50 条
  • [21] Effect of openings on the behaviour of fibre reinforced concrete and masonry infilled RC frames
    Ganesan, N.
    Irshad, P.
    Indira, P.V.
    Indian Concrete Journal, 2019, 98 (01): : 8 - 15
  • [22] Numerical Study of Masonry-Infilled RC Frames Retrofitted with ECC Overlays
    Koutromanos, Ioannis
    Shing, P. Benson
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (07)
  • [23] Numerical modeling of masonry-infilled RC frames subjected to seismic loads
    Koutromanos, Ioannis
    Stavridis, Andreas
    Shing, P. Benson
    Willam, Kaspar
    COMPUTERS & STRUCTURES, 2011, 89 (11-12) : 1026 - 1037
  • [24] Numerical Modeling Technique of Damage Behavior of MaSonry-Infilled RC Frames
    Liu, Bo
    Liu, Chunhui
    Wang, Xiaomin
    Kong, Jingchang
    Chang, Zhiwang
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [25] Numerical analysis of the in-plane behaviour of decoupled masonry infilled RC frames
    Marinkovic, Marko
    Butenweg, Christoph
    ENGINEERING STRUCTURES, 2022, 272
  • [26] ROLE OF MASONRY INFILL IN SEISMIC RESISTANCE OF RC STRUCTURES
    Taher, Salah El-Din Fahmy
    Afefy, Hamdy Mohy El-Din
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2008, 33 (2B): : 291 - 306
  • [27] Cyclic response of masonry infilled RC frames: Experimental results and simplified modeling
    Cavaleri, Liborio
    Di Trapani, Fabio
    Soil Dynamics and Earthquake Engineering, 2014, 65 : 224 - 242
  • [28] Effect of openings on the behaviour of fibre reinforced concrete and masonry infilled RC frames
    Ganesan, N.
    Irshad, P.
    Indira, P.V.
    Indian Concrete Journal, 2019, 93 (01): : 8 - 15
  • [29] Cyclic response of masonry infilled RC frames: Experimental results and simplified modeling
    Cavaleri, L. (liborio.cavaleri@unipa.it), 1600, Elsevier Ltd (65):
  • [30] Seismic Strengthening of Masonry-Infilled RC Frames with TRM: Experimental Study
    Koutas, L.
    Bousias, S. N.
    Triantafillou, T. C.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (02)