Mechanical Assistance by Intra-Aortic Balloon Pump Counterpulsation During Reperfusion Increases Coronary Blood Flow and Mitigates the No-Reflow Phenomenon: An Experimental Study

被引:24
|
作者
Pierrakos, Charalampos N. [1 ]
Bonios, Michael J. [1 ]
Drakos, Stavros G. [1 ]
Charitos, Efstratios I. [1 ]
Tsolakis, Elias J. [1 ]
Ntalianis, Argirios [1 ]
Nanas, Serafim N. [2 ]
Charitos, Christos E. [3 ]
Nanas, John N. [1 ]
Terrovitis, John V. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 3, GR-11527 Athens, Greece
[2] Univ Athens, Sch Med, Dept Pulm & Crit Care Med, GR-11527 Athens, Greece
[3] Evangelismos Med Ctr, Dept Cardiac Surg 2, Athens, Greece
关键词
Myocardial infarction; Intra-aortic balloon pump; Coronary circulation; Blood flow; Reperfusion; ACUTE MYOCARDIAL-INFARCTION; CARDIOGENIC-SHOCK; MICROVASCULAR OBSTRUCTION; LEUKOCYTE ACCUMULATION; ISCHEMIA; SIZE; THROMBOLYSIS; SURVIVAL; INJURY; AUGMENTATION;
D O I
10.1111/j.1525-1594.2011.01241.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of the intra-aortic balloon pump (IABP) counterpulsation on the extent of myocardial infarction (MI), the no-reflow phenomenon (NRP), and coronary blood flow (CBF) during reperfusion in an ischemia-reperfusion experimental model have not been clarified. Eleven pigs underwent occlusion of the mid left anterior descending coronary artery for 1 h, followed by reperfusion for 2 h. CBF, distal to the occlusion site, was measured. In six experiments, IABP support began 10 min before, and continued throughout reperfusion (IABP Group). Five pigs without IABP support served as controls. At the end of each experiment, the myocardial area at risk (MAR) of infarction and the extent of MI and NRP were measured. Hemodynamic measurements at baseline and during coronary occlusion were similar in both groups. During reperfusion, systolic aortic blood pressure was significantly lower in the IABP Group than in controls. In the IABP Group, CBF reached a peak at 5 min of reperfusion, gradually decreased, but remained higher than at baseline, and significantly higher than in controls throughout the 2 h of reperfusion. In controls, CBF increased significantly above baseline immediately after the onset of reperfusion, then returned to baseline within 90 min. The extent of NRP (37 +/- 25% vs. 68 +/- 17%, P = 0.047) and MI (39 +/- 23% vs. 67 +/- 13%, P = 0.036), both expressed as percentage of MAR, was significantly less in the IABP group than in controls. After prolonged myocardial ischemia, IABP assistance started just 10 min before and throughout reperfusion increased CBF and limited infarct size and extent of NRP.
引用
收藏
页码:867 / 874
页数:8
相关论文
共 50 条
  • [1] Intra-aortic balloon counterpulsation during myocardial reperfusion increases coronary blood flow and myocardial salvage: Experimental study
    Bonios, M
    Ntalianis, A
    Stavrakis, S
    Drakos, S
    Savvari, P
    Koudoumas, D
    Dolou, P
    Pierrakos, C
    Papalois, A
    Nanas, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 253A - 253A
  • [2] Intra-aortic balloon counterpulsation decreased the extent of the no-reflow phenomenon and infarct size in an ischaemia/reperfusion experimental model
    Terrovitis, J
    Charitos, C
    Pierrakos, C
    Tsolakis, E
    Charitos, E
    Glentis, P
    Argiriou, M
    Nanas, JN
    EUROPEAN HEART JOURNAL, 2004, 25 : 191 - 191
  • [3] Intra-aortic balloon counterpulsation increased coronary blood flow during reperfusion in an ischaemia/reperfusion experimental model but not in the intact heart
    Pierrakos, C
    Charitos, C
    Terrovitis, J
    Dolou, P
    Argiriou, M
    Glentis, P
    Koudoumas, D
    Nanas, JN
    EUROPEAN HEART JOURNAL, 2004, 25 : 188 - 189
  • [4] Intra-aortic balloon counterpulsation facilitates coronary microcirculation during myocardial reperfusion: Experimental study
    Tsolakis, E
    Ntallanis, A
    Drakos, S
    Savvari, P
    Charitos, S
    Pierrakos, C
    Argiriou, M
    Nanas, J
    CIRCULATION RESEARCH, 2005, 97 (02) : E41 - E41
  • [5] MECHANICAL CIRCULATORY ASSISTANCE WITH THE INTRA-AORTIC BALLOON PUMP AND OTHER COUNTERPULSATION DEVICES
    SCHEIDT, S
    COLLINS, M
    GOLDSTEIN, J
    FISHER, J
    PROGRESS IN CARDIOVASCULAR DISEASES, 1982, 25 (01) : 55 - 76
  • [6] Reduction of "No-Reflow" phenomenon by intra-aortic batloon counterpulsation in a randomized magnetic resonance Imaging experimental study
    Amado, LC
    Kraitchman, DL
    Gerber, BL
    Castillo, E
    Boston, RC
    Grayzel, J
    Lima, JAC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1291 - 1298
  • [7] Increase in coronary blood flow by intra-aortic balloon counterpulsation in a porcine model of myocardial reperfusion
    Bonios, Michael J.
    Pierrakos, Charalampos N.
    Argiriou, Michael
    Dalianis, Argirios
    Terrovitis, John V.
    Dolou, Paraskevi
    Drakos, Stavros G.
    Koudoumas, Dimitrios
    Charitos, Christos E.
    Anastasiou-Nana, Maria I.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 138 (03) : 253 - 260
  • [8] NUTRIENT MYOCARDIAL BLOOD-FLOW IN EXPERIMENTAL MYOCARDIAL ISCHEMIA - EFFECTS OF INTRA-AORTIC BALLOON COUNTERPULSATION AND CORONARY REPERFUSION
    SAINI, VK
    HOOD, WB
    HECHTMAN, HB
    BERGER, RL
    CIRCULATION, 1975, 52 (06) : 1086 - 1090
  • [9] Effect of Intra-aortic Balloon Pump on Coronary Blood Flow during different balloon cycles Support: A Computer Study
    Aye, Thin Pa Pa
    Htet, Zwe Lin
    Singhavilai, Thamvarit
    Naiyanetr, Phornphop
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3303 - 3306
  • [10] EFFECTS OF INTRA-AORTIC BALLOON COUNTERPULSATION ON REGIONAL CORONARY BLOOD-FLOW IN EXPERIMENTAL MYOCARDIAL-INFARCTION
    SHAW, J
    TAYLOR, DR
    PITT, B
    AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (05): : 552 - 556