New superconducting electron cyclotron resonance ion source for RKEN RI beam factory project

被引:9
|
作者
Nakagawa, T. [1 ]
Kidera, M. [1 ]
Higurashi, Y. [1 ]
Ohonishi, J. [1 ]
Goto, A. [1 ]
Yano, Y. [1 ]
机构
[1] RIKEN, Nishina Ctr Accelerator Based Sci, Wako, Saitama 3510198, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 02期
关键词
D O I
10.1063/1.2801683
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For RIKEN radio isotope beam project, we started to construct the new superconducting electron cyclotron resonance ion source (SC-ECRIS), which has an operational frequency of 28 GHz, in 2007. The main feature of this ion source is that we can produce large size of resonance zone with six sets of solenoid coils. Before starting, we intensively studied the effect of several key parameters of ECRIS (magnetic field configuration, microwave power density, negatively biased disk) on the plasma. In this article, we describe the effect of key parameters on the plasma and detailed structure of the new SC-ECRIS. (C) 2008 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Summary of the performances of the superconducting electron cyclotron resonance ion source at 14 GHz
    Ludwig, P
    Bourg, F
    Briand, P
    Girard, A
    Melin, G
    Guillaume, D
    Seyfert, P
    La Grassa, A
    Ciavola, G
    Gammino, S
    Castro, M
    Chines, F
    Marletta, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12): : 4082 - 4085
  • [22] Summary of the performances of the superconducting electron cyclotron resonance ion source at 14 GHz
    CEA, Grenoble, France
    Rev Sci Instrum, 12 (4082-4085):
  • [23] Results of RIKEN superconducting electron cyclotron resonance ion source with 28 GHz
    Higurashi, Y.
    Ohnishi, J.
    Nakagawa, T.
    Haba, H.
    Tamura, M.
    Aihara, T.
    Fujimaki, M.
    Komiyama, M.
    Uchiyama, A.
    Kamigaito, O.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [24] Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP
    Yorita, Tetsuhiko
    Hatanaka, Kichiji
    Fukuda, Mitsuhiro
    Kibayashi, Mitsuru
    Morinobu, Shunpei
    Okamura, Hiroyuki
    Tamii, Atsushi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [25] 18 GHz upgrading of the superconducting electron cyclotron resonance ion source SERSE
    INFN-Laboratori Nazionali del Sud, 95123 Catania, Italy
    Rev. Sci. Instrum., 9 (3577-3582):
  • [27] Operation of the SERSE superconducting electron cyclotron resonance ion source at 28 GHz
    Gammino, S
    Ciavola, G
    Celona, L
    Hitz, D
    Girard, A
    Melin, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11): : 4090 - 4097
  • [28] Simulation and beamline experiments for the superconducting electron cyclotron resonance ion source VENUS
    Todd, Damon S.
    Leitner, Daniela
    Lyneis, Claude M.
    Grote, David P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [29] Design and investigations of the superconducting magnet system for the multipurpose superconducting electron cyclotron resonance ion source
    Tinschert, K.
    Lang, R.
    Maeder, J.
    Rossbach, J.
    Spaedtke, P.
    Komorowski, P.
    Meyer-Reumers, M.
    Krischel, D.
    Fischer, B.
    Ciavola, G.
    Gammino, S.
    Celona, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [30] Afterglow mode and the new micropulsed beam mode applied to an electron cyclotron resonance ion source
    Maunoury, L.
    Adoui, L.
    Grandin, J. P.
    Noury, F.
    Huber, B. A.
    Lamour, E.
    Prigent, C.
    Rozet, J. P.
    Vernhet, D.
    Leherissier, P.
    Pacquet, J. Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):