Molecularly imprinted QCM sensor based on delaminated MXene for chlorpyrifos detection and QCM sensor validation

被引:72
|
作者
Kadirsoy, Selcen [1 ]
Atar, Necip [2 ]
Yola, Mehmet Lutfi [3 ]
机构
[1] Iskenderun Tech Univ, Dept Chem Biol Radiol, Nucl CBRN Threats Management, Antakya, Turkey
[2] Pamukkale Univ, Fac Engn Denizli, Dept Chem Engn, Denizli, Turkey
[3] Iskenderun Tech Univ, Fac Engn & Nat Sci, Dept Biomed Engn, Antakya, Turkey
关键词
GLASSY-CARBON; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETERMINATION; QUANTUM DOTS; NANOSHEETS; SURFACE;
D O I
10.1039/d0nj00951b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Chlorpyrifos (CHL) is one of the most frequently used broad-spectrum organophosphate insecticides. Especially, its incorrect and uncontrolled usage cause public concern about food and environment safety. In this report, a new molecularly imprinted quartz crystal microbalance (QCM) sensor on delaminated sulfur-doped MXene (d-S-Ti3C2TX MXene) was prepared for CHL. The structures of the bare MAX phase (Ti3AlC2), sulfur-doped MAX phase (S-Ti3AlC2), wrinkled sulfur-doped MXene (S-Ti3C2TX MXene) and d-S-Ti3C2SX MXene were highlighted by scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and X-ray diffraction (XRD). The CHL imprinted QCM sensor was prepared in the presence of MAGA and CHL in 2 : 1 molar ratio. From the analytical results 1.0 x 10(-12)-1.0 x 10(-10) M and 3.0 x 10(-13) M were found to be the linearity range and detection limit (LOD), respectively. Furthermore, the CHL imprinted QCM sensor was examined in terms of stability, repeatability, reproducibility and reusability. Finally, the imprinted sensor was applied to orange juice samples, and a high recovery was obtained.
引用
收藏
页码:6524 / 6532
页数:9
相关论文
共 50 条
  • [31] FABRICATION AND EXPERIMENT OF A HYDROGEN SENSOR BASED ON PIEZOELECTRIC QCM
    Deng, Li-song
    Wei, Lei-kai
    PROCEEDINGS OF THE 2020 15TH SYMPOSIUM ON PIEZOELECTRCITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2021, : 526 - 530
  • [32] Magnetic MXene-based molecularly imprinted electrochemical sensor for methylmalonic acid
    Xing, Ying
    Ding, Xin
    Liang, Xilin
    Liu, Guangyan
    Hou, Shili
    Hou, Shifeng
    MICROCHIMICA ACTA, 2023, 190 (06)
  • [33] A quartz crystal microbalance (QCM) sensor for the detection of Bacillus cereus
    Vaughan, RD
    Carter, RM
    O'Sullivan, CK
    Guilbault, GG
    ANALYTICAL LETTERS, 2003, 36 (04) : 731 - 747
  • [34] A new polysiloxane coating on QCM sensor for DMMP vapor detection
    Du, Xiaosong
    Wang, Zhidong
    Huang, Jia
    Tao, Silu
    Tang, Xianzhong
    Jiang, Yadong
    JOURNAL OF MATERIALS SCIENCE, 2009, 44 (21) : 5872 - 5876
  • [35] A new polysiloxane coating on QCM sensor for DMMP vapor detection
    Xiaosong Du
    Zhidong Wang
    Jia Huang
    Silu Tao
    Xianzhong Tang
    Yadong Jiang
    Journal of Materials Science, 2009, 44 : 5872 - 5876
  • [36] Polymer coated QCM sensor with modified electrode for the detection of DDVP
    Zeng, Hongjuan
    Jiang, Yadong
    Xie, Guangzhong
    Yu, Junsheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 1 - 6
  • [37] Molecularly imprinted biomimetic QCM sensor involving a poly(amidoamine) dendrimer as a functional monomer for the highly selective and sensitive determination of methimazole
    Pan, Mingfei
    Fang, Guozhen
    Lu, Yang
    Kong, Lingjie
    Yang, Yukun
    Wang, Shuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 588 - 595
  • [38] Photoelectrochemical sensor based on molecularly imprinted film modified hierarchical branched titanium dioxide nanorods for chlorpyrifos detection
    Sun, Xiaolu
    Gao, Chaomin
    Zhang, Lina
    Yan, Mei
    Yu, Jinghua
    Ge, Shenguang
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 1 - 8
  • [39] Fabrication of electrochemical sensor based on molecularly imprinted polymers for monitoring chlorpyrifos in real samples
    Singh, Damnita
    Verma, Neelam
    Bhari, Ranjeeta
    Kumar, Kuldeep
    BULLETIN OF MATERIALS SCIENCE, 2024, 47 (02)
  • [40] Electrochemical Sensor for Determination of Chlorpyrifos Based on Graphene Modified Electrode and Molecularly Imprinted Polymer
    Tan Xue-Cai
    Wu Jia-Wen
    Hu Qi
    Li Xiao-Yu
    Li Peng-Fei
    Yu Hui-Cheng
    Li Xiao-Yan
    Lei Fu-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (03) : 387 - 393