Measuring Temporal and Spatial Variability of Red Blood Cell Velocity in Human Retinal Vessels

被引:10
|
作者
Warner, Raymond L. [1 ]
Gast, Thomas J. [1 ]
Sapoznik, Kaitlyn A. [1 ]
Carmichael-Martins, Alessandra [1 ]
Burns, Stephen A. [1 ]
机构
[1] Indiana Univ, Sch Optometry, 800 East Atwater Ave, Bloomington, IN 47405 USA
基金
美国国家卫生研究院;
关键词
blood flow; retinal imaging; neurovascular coupling; OPTIC-NERVE; GLAUCOMA PATIENTS; OXYGEN-TENSION; FLOW; FLICKER; CAPILLARIES; CIRCULATION; MECHANISMS; LUMINANCE; PERICYTES;
D O I
10.1167/iovs.62.14.29
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The retinal circulation regulates blood flow through various internal and external factors; however, it is unclear how locally these factors act within the retinal microcirculation. We measured the temporal and spatial variability of blood velocity in small retinal vessels using a dual-beam adaptive optics scanning laser ophthalmoscope. METHODS. In young healthy subjects (n = 3), temporal blood velocity variability was measured in a local vascular region consisting of an arteriole, capillary, and venule repeatedly over 2 days. Data consisted of 10 imaging periods separated into two sessions: (1) five 6-minute image acquisition periods with 30-minute breaks, and (2) five 6-minute image acquisition periods with 10-minute breaks. In another group of young healthy subjects (n = 5), spatial distribution of velocity variability was measured by imaging three capillary segments during three 2-minute conditions: (1) baseline imaging condition (no flicker), (2) full-field flicker, and (3) no flicker condition again. RESULTS. Blood velocities were measurable in all subjects with a reliability of about 2%. The coefficient of variation (CV) was used as an estimate of the physiological variability of each vessel. Over 2 days, the average CV in arterioles was 7% (+/- 2%); in capillaries, it was 19% (+/- 6%); and, in venules, it was 8% (+/- 2%). During flicker stimulation, the average capillary CV was 16% during baseline, 15% during flicker stimulation, and 18% after flicker stimulation. CONCLUSIONS. Capillaries in the human retina exhibit spatial and temporal variations in blood velocity. This inherent variation in blood velocity places limits on studying the vascular regulation of individual capillaries, and the study presented here serves as a foundation for future endeavors.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Imaging of cellular aging in human retinal blood vessels
    Catita, J.
    Lopez-Luppo, M.
    Ramos, D.
    Nacher, V.
    Navarro, M.
    Carretero, A.
    Sanchez-Chardi, A.
    Mendes-Jorge, L.
    Rodriguez-Baeza, A.
    Ruberte, J.
    EXPERIMENTAL EYE RESEARCH, 2015, 135 : 14 - 25
  • [22] FRACTAL ANALYSIS OF NORMAL HUMAN RETINAL BLOOD VESSELS
    Masters, Barry R.
    FRACTALS-COMPLEX GEOMETRY PATTERNS AND SCALING IN NATURE AND SOCIETY, 1994, 2 (01) : 103 - 110
  • [23] EVALUATION OF THE FLYING SPOT TECHNIQUE AS A TELEVISION METHOD FOR MEASURING RED-CELL VELOCITY IN MICRO-VESSELS
    TYML, K
    ELLIS, CG
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (02): : 145 - 155
  • [24] BLOOD VELOCITY-MEASUREMENT IN HUMAN CONJUNCTIVAL VESSELS
    MAYROVITZ, HN
    LARNARD, D
    DUDA, G
    CARDIOVASCULAR DISEASES, 1981, 8 (04): : 509 - 526
  • [26] A NEW METHOD FOR VISUALIZATION AND MEASUREMENT OF THE RED-CELL VELOCITY PROFILE IN SMALL BLOOD-VESSELS
    BERMAN, HJ
    AARON, A
    BEHRMAN, S
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1759 - 1759
  • [27] SYSTEM FOR MEASURING CAPILLARY RED-CELL VELOCITY
    GOODMAN, AH
    GUYTON, AC
    FEDERATION PROCEEDINGS, 1973, 32 (03) : 323 - &
  • [28] Estimation of real blood velocity measured by laser speckle flowgraphy at retinal vessels
    Tagawa, H
    Sasaki, N
    Tashimo, A
    Suzuki, T
    Shimizu, M
    Fujii, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S369 - S369
  • [29] Measuring spatial integration in retinal ganglion cell dendrites
    Fadjukov, Julia Kristiina
    Schwartz, Greg
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [30] Contributions on the question of the speed of reduction of red blood vessels in human blood
    von Oettingen, R
    BIOCHEMISCHE ZEITSCHRIFT, 1921, 118 : 67 - 92