Correlation between hydroxyapatite crystallite orientation and ultrasonic wave velocities in bovine cortical bone

被引:36
|
作者
Yamato, Yu [1 ]
Matsukawa, Mami [2 ]
Yanagitani, Takahiko [2 ]
Yamazaki, Kaoru [1 ]
Mizukawa, Hirofumi [2 ]
Nagano, Akira [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Orthopaed Surg, Shizuoka 4313192, Japan
[2] Doshisha Univ, Fac Engn, Kyoto 6100321, Japan
基金
日本学术振兴会;
关键词
bone density technology; ultrasound; crystal structure; crystallinity; bone histology; histomorphometry; bone architecture; structure;
D O I
10.1007/s00223-008-9103-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mineral component of bone is mainly composed of calcium phosphate, constituting 70% of total bone mass almost entirely in the form of hydroxyapatite (HAp) crystals. HAp crystals have a hexagonal system and uniaxial elastic anisotropy. The objective of this study was to investigate the effect of HAp crystallite preference on macroscopic elasticity. Ultrasonic longitudinal wave velocity and the orientation of HAp crystallites in bovine cortical bone are discussed, considering microstructure, density, and bone mineral density (BMD). Eighty cube samples of cortical bone were made from two bovine femurs. The orientation of HAp crystallites was evaluated by integrated intensity ratio of (0002) peak using an X-ray diffractometer. Ultrasonic longitudinal wave velocity was investigated with a conventional pulse system. The intensity ratio of HAp crystallites and velocity were measured in three orthogonal directions; most HAp crystallites aligned in the axial direction of the femurs. Our results demonstrate a linear correlation between velocity and intensity ratio in the axial direction. Significant correlation between velocity and BMD values was observed; however, the correlation disappeared if we focused on the identical type of microstructure. In conclusion, differences in microstructure type have an impact on density and BMD, which clearly affects the velocity. In addition, at the nanoscopic level, HAp crystallites aligned in the axial direction also affected the velocity and anisotropy.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 50 条
  • [31] Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens
    Kohles, SS
    Bowers, JR
    Vailas, AC
    Vanderby, R
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 232 - 236
  • [32] Propagation of Ultrasonic Longitudinal Wave in the Cancellous bone covered by the subchondral bone of bovine femur
    Koizumi, Takaaki
    Yamamoto, Kazufumi
    Nagatani, Yoshiki
    Soumiya, Hiroki
    Saeki, Takashi
    Yaoi, Yuichiro
    Matsukawa, Mami
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 146 - +
  • [33] Anisotropy of Longitudinal Wave Velocity in Spherically Shaped Bovine Cortical Bone
    Yamamoto, K.
    Nakatsuji, T.
    Indo, M.
    Yanagitani, T.
    Matsukawa, M.
    Yamazaki, K.
    THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 102 - +
  • [34] Influences of trabecular structure on ultrasonic wave propagation in bovine cancellous bone
    Hosokawa, Atsushi
    Otani, Takahiko
    Suzaki, Takuji
    Kubo, Yoshiomi
    Takai, Shinro
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (5 B): : 3233 - 3237
  • [35] Influences of trabecular structure on ultrasonic wave propagation in bovine cancellous bone
    Hosokawa, A
    Otani, T
    Suzaki, T
    Kubo, Y
    Takai, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B): : 3233 - 3237
  • [36] CORRELATION BETWEEN TOPOLOGICAL ASPECTS AND ULTRASONIC VELOCITIES OF BINARY-LIQUID MIXTURES
    DEWAN, RK
    MEHTA, SK
    ACUSTICA, 1992, 76 (03): : 142 - 145
  • [37] Interfacial fracture toughness between bovine cortical bone and cements
    Lucksanasombool, P
    Higgs, WAJ
    Higgs, RJED
    Swain, MV
    BIOMATERIALS, 2003, 24 (07) : 1159 - 1166
  • [38] THE RELATIONSHIP BETWEEN ELASTIC PROPERTIES AND MICROSTRUCTURE OF BOVINE CORTICAL BONE
    LIPSON, SF
    KATZ, JL
    JOURNAL OF BIOMECHANICS, 1984, 17 (04) : 231 - +
  • [39] Deformation and Orientation of HAp Crystals at Osteon-Scale Structure in Bovine Cortical Bone
    Kodaki, Y.
    Yamada, S.
    Fujisaki, K.
    Tadano, S.
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 819 - +
  • [40] CORRELATION BETWEEN ORIENTATION OF HYDROXYAPATITE AND MECHANICAL ANISOTROPY IN LOXODONTA-AFRICANA IVORY
    NOTHNAGEL, G
    LEROUX, SD
    GROTEPASS, WP
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 1014 - 1014