Flexible Screen-Printed Electrochemical Sensors Functionalized with Electrodeposited Copper for Nitrate Detection in Water

被引:39
|
作者
Inam, A. K. M. S. [1 ,2 ]
Angeli, Martina A. Costa [1 ]
Shkodra, Bajramshahe [1 ]
Douaki, Ali [1 ]
Avancini, Enrico [1 ]
Magagnin, Luca [3 ]
Petti, Luisa [1 ]
Lugli, Paolo [1 ]
机构
[1] Free Univ Bozen Bolzano, Fac Sci & Technol, I-39100 Bolzano, Italy
[2] Daffodil Int Univ, Dept Nutr & Food Engn, Dhaka 1207, Bangladesh
[3] Dept Chem Mat & Chem Engn Giulio Natta, I-20133 Milan, Italy
来源
ACS OMEGA | 2021年 / 6卷 / 49期
关键词
ELECTROCATALYTIC REDUCTION; RAPID DETECTION; REAL-TIME; NITRITE; PLATINUM; ARRAYS; NANOSTRUCTURES; NANOPARTICLES; MECHANISM; FACILE;
D O I
10.1021/acsomega.1c04296
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nitrate (NO3-) contamination is becoming a major concern due to the negative effects of an excessive NO3- presence in water which can have detrimental effects on human health. Sensitive, real-time, low-cost, and portable measurement systems able to detect extremely low concentrations of NO3- in water are thus becoming extremely important. In this work, we present a novel method to realize a low-cost and easy to fabricate amperometric sensor capable of detecting small concentrations of NO3- in real water samples. The novel fabrication technique combines printing of a silver (Ag) working electrode with subsequent modification of the electrode with electrodeposited copper (Cu) nanoclusters. The process was tuned in order to reach optimized sensor response, with a high catalytic activity toward electroreduction of NO3- - (sensitivity: 19.578 mu A/mM), as well as a low limit of detection (LOD: 0.207 nM or 0.012 mu g/L) and a good dynamic linear concentration range (0.05 to 5 mM or 31 to 310 mg/L). The sensors were tested against possible interference analytes (NO2-, Cl-, SO42-, HCO3-, CH3COO-, Fe2+,Fe3-, Mn2+, Na+, and Cu2+) yielding only negligible effects [maximum standard deviation (SD) was 3.9 mu A]. The proposed sensors were also used to detect NO 3 - in real samples, including tap and river water, through the standard addition method, and the results were compared with the outcomes of high-performance liquid chromatography (HPLC). Temperature stability (maximum SD 3.09 mu A), stability over time (maximum SD 3.69 mu A), reproducibility (maximum SD 3.20 mu A), and repeatability (maximum two-time useable) of this sensor were also investigated.
引用
收藏
页码:33523 / 33532
页数:10
相关论文
共 50 条
  • [21] Screen-Printed Sensors Modified with Nafion and Mesoporous Carbon for Electrochemical Detection of Lead in Blood
    Boselli, Elena
    Wu, Zhizhen
    Haynes, Erin N.
    Papautsky, Ian
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (02)
  • [22] SCREEN-PRINTED VOLTAMMETRIC AND AMPEROMETRIC ELECTROCHEMICAL SENSORS FOR DECENTRALIZED TESTING
    HART, JP
    WRING, SA
    ELECTROANALYSIS, 1994, 6 (08) : 617 - 624
  • [23] Amino Acid Determination Using Screen-Printed Electrochemical Sensors
    Majlinda Vasjari
    Arben Merkoçi
    John P. Hart
    Salvador Alegret
    Microchimica Acta, 2005, 150 : 233 - 238
  • [24] An Overview of Biochar Utilization Strategies for Screen-Printed Electrochemical Sensors
    Sarakhman, Olha
    Svorc, L'ubomir
    Labuda, Jan
    CHEMICKE LISTY, 2024, 118 (10): : 539 - 548
  • [25] Facile Fabrication of Screen-Printed Carbon Electrodes for Electrochemical Sensors
    Sarmphim, P.
    Teeparuksapun, K.
    Wunsri, S.
    Sorngodchagorn, S.
    Duangsiri, W.
    Tapparak, P.
    Sirisathitkul, C.
    INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2021, 14 (01): : 1 - 10
  • [26] Amino acid determination using screen-printed electrochemical sensors
    Vasjari, M
    Merkoçi, A
    Hart, JP
    Alegret, S
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 233 - 238
  • [27] Screen-printed integrated microsystem for the electrochemical detection of pathogens
    Mata, D.
    Bejarano, D.
    Botero, M. L.
    Lozano, P.
    Constanti, M.
    Katakis, I.
    ELECTROCHIMICA ACTA, 2010, 55 (14) : 4261 - 4266
  • [28] Screen-Printed Electrochemical Biosensor for Detection of DNA Hybridization
    Chen Sheng-Zhen
    Cai Qiang
    Peng Fang-Yi
    Huang Xin-Xin
    Jia Yu-Ling
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (08) : 1194 - 1199
  • [29] Correlations between the grafting conditions and the copper detection by diazonium functionalized carbon screen-printed electrodes
    Bouden, Sarra
    Bellakhal, Nizar
    Chausse, Annie
    Dachraoui, Mohamed
    Vautrin-Ul, Christine
    ELECTROCHIMICA ACTA, 2014, 125 : 149 - 155
  • [30] Recent advances in nanomaterial-enabled screen-printed electrochemical sensors for heavy metal detection
    Liu, Xiaoxue
    Yao, Yao
    Ying, Yibin
    Ping, Jianfeng
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 115 (187-202) : 187 - 202