Sprayed concrete for primary tunnel lining

被引:0
|
作者
Polak, P. [1 ]
Cyron, D. [1 ]
Vlasimsky, J.
Mika, V.
机构
[1] Metrostav As, Prague, Czech Republic
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The process of adding accelerators to sprayed concrete of the primary lining applied by Metrostav during the course of the Vitkov tunnels excavation has been monitored in a systematic manner. In addition to the customary check testing carried out to verify whether the set/hardness build-up curves prescribed are maintained, also other relevant quantities were monitored and recorded, e.g. the concrete mixture temperature, ambient temperature, consistency of the mixture and dosage of additives. Also the concrete application by the nozzle operator was monitored, with a view to the correctness of the procedure. The results are currently being assessed and should be used not only as a basis for the development of modified sprayed concrete formulas to be applied in the conditions of production in a certified concrete mixing plant but also for the determination of the minimum theoretical and practical requirements for qualification testing of nozzle operators.
引用
收藏
页码:1383 / +
页数:2
相关论文
共 50 条
  • [11] Compressive strength prediction of sprayed concrete lining in tunnel engineering using hybrid machine learning techniques
    Yin, Xin
    Gao, Feng
    Wu, Jian
    Huang, Xing
    Pan, Yucong
    Liu, Quansheng
    UNDERGROUND SPACE, 2022, 7 (05) : 928 - 943
  • [12] Damage in Concrete Lining of an Operational Tunnel
    Zhang, Yongxing
    Shi, Yufeng
    Zhao, Yiding
    Yang, Junsheng
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (04)
  • [13] The future of sprayed concrete tunnel linings
    Thomas, Alun
    Concrete (London), 2002, 36 (04):
  • [14] Spiling bolts and reinforced ribs of sprayed concrete replace concrete lining
    Holmoy, KH
    Aagaard, B
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2002, 17 (04) : 403 - 413
  • [15] Sprayed concrete lining – Improving safety through design
    Kumpfmüller S.
    Feiersinger A.
    Doulkas G.
    Geomechanik und Tunnelbau, 2019, 12 (06): : 745 - 750
  • [16] The effect of tunnel lining modelling approaches on the seismic response of sprayed concrete tunnels in coarse-grained soils
    Kampas, G.
    Knappett, J. A.
    Brown, M. J.
    Anastasopoulo, I.
    Nikitas, N.
    Fuentes, R.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 117 : 122 - 137
  • [17] Inspection Test of a Tunnel with an Inspection Vehicle for Tunnel Lining Concrete
    Nakamura, Satoru
    Yamashita, Atsushi
    Inoue, Fumihiro
    Inoue, Daisuke
    Takahashi, Yusuke
    Kamimura, Nobukazu
    Ueno, Takao
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2019, 31 (06) : 762 - 771
  • [18] FIBRE REINFORCED CONCRETE FOR TUNNEL LINING SEGMENT
    Racek, Vaclav
    Vodicka, Jan
    Kratky, Jiri
    Hilar, Matous
    19TH CZECH CONCRETE DAY 2012 / 19 BETONARSKE DNY 2012, 2012, : 336 - 341
  • [19] Analysis of extruded concrete lining tunnel by FEM
    Kimenai, MCW
    Hoefsloot, FJM
    BEYOND 2000 IN COMPUTATIONAL GEOTECHNICS: 10 YEARS OF PLAXIS INTERNATIONAL, 1999, : 185 - 196
  • [20] Permeability model of cracked tunnel lining concrete
    Institute of Geotechnical Engineering, Chongqing Jiaotong University, Chongqing 400074, China
    不详
    不详
    Tiedao Xuebao/Journal of the China Railway Society, 2008, 30 (02): : 124 - 127