Sprayed concrete for primary tunnel lining

被引:0
|
作者
Polak, P. [1 ]
Cyron, D. [1 ]
Vlasimsky, J.
Mika, V.
机构
[1] Metrostav As, Prague, Czech Republic
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The process of adding accelerators to sprayed concrete of the primary lining applied by Metrostav during the course of the Vitkov tunnels excavation has been monitored in a systematic manner. In addition to the customary check testing carried out to verify whether the set/hardness build-up curves prescribed are maintained, also other relevant quantities were monitored and recorded, e.g. the concrete mixture temperature, ambient temperature, consistency of the mixture and dosage of additives. Also the concrete application by the nozzle operator was monitored, with a view to the correctness of the procedure. The results are currently being assessed and should be used not only as a basis for the development of modified sprayed concrete formulas to be applied in the conditions of production in a certified concrete mixing plant but also for the determination of the minimum theoretical and practical requirements for qualification testing of nozzle operators.
引用
收藏
页码:1383 / +
页数:2
相关论文
共 50 条
  • [1] CONTINUOUS SPRAYED CONCRETE TUNNEL LINING.
    Ryan, T.F.
    Tunnels and Tunnelling, 1973, 5 (06): : 542 - 543
  • [2] Utilisation of Fibre Reinforced Sprayed Concrete for Primary Lining of the Povazsky Chlmec Tunnel
    Balaz, M.
    Uhrin, M.
    Ruzicka, P.
    Hilar, M.
    FIBRE CONCRETE 2017, 2017, 246
  • [3] Fiber-Reinforced Sprayed Concrete as a Permanent Tunnel Lining
    Larive, Catherine
    Bouteille, Sebastien
    Berthoz, Nicolas
    Zappelli, Serge
    STRUCTURAL ENGINEERING INTERNATIONAL, 2020, 30 (04) : 498 - 505
  • [4] New developments in tunnel supports in the field of sprayed concrete and the production of tunnel lining elements
    Bracher, G
    Schumperli, E
    TUNNELLING ASIA '97,- SELECT PAPERS, 1997, : 289 - 299
  • [5] In-situ analysis of sprayed concrete in a sewage tunnel lining.
    Coni, Gabriella de Andrade
    de Figueiredo, Antonio Domingues
    Salvador, Renan Picolo
    Monte, Renata
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [6] Integrated approach for quality control of fibre-reinforced sprayed concrete for tunnel lining
    Caceres, Alan Renato Estrada
    Cavalaro, Sergio H. P.
    Figueiredo, Antonio Domingues de
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 140
  • [7] Flexible lining or NATM versus stiff lining or sprayed concrete lining (SCL)
    Launay, J
    GEOTECHNICS OF HARD SOILS - SOFT ROCKS, VOL 2, 1998, : 977 - 987
  • [8] Mechanical behaviour of a sprayed concrete lining isolated by a sprayed waterproofing membrane
    Nakashima, Masanari
    Hammer, Anna-Lena
    Thewes, Markus
    Elshafie, Mohammed
    Soga, Kenichi
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 47 : 143 - 152
  • [9] Research on fiber concrete of tunnel lining
    Ouyang, Wei
    ADVANCED MATERIALS AND ENERGY SUSTAINABILITY, 2017, : 303 - 309
  • [10] Concrete lining construction for tailwater tunnel
    Ren Min Chang Jiang, 4 (13-14, 22):