Sodium dodecyl sulfate coated alumina modified with a new Schiff's base as a uranyl ion selective adsorbent

被引:30
|
作者
Tashkhourian, J. [1 ]
Abdoluosofi, L. Moradi [2 ]
Pakniat, M. [2 ]
Montazerozohoric, M. [3 ]
机构
[1] Shiraz Univ, Coll Sci, Dept Chem, Shiraz 71454, Iran
[2] Persian Gulf Univ, Fac Sci, Dept Chem, Bushehr 75169, Iran
[3] Univ Yasuj, Fac Sci, Dept Chem, Yasuj, Iran
关键词
Uranyl; Schiff's base; Solid phase extraction; SOLID-PHASE EXTRACTION; LIQUID-LIQUID-EXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; URANIUM(VI); WATER; SORBENT;
D O I
10.1016/j.jhazmat.2010.12.053
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and selective method was used for the preconcentration and determination of uranium(VI) by solid-phase extraction (SPE). In this method, a column of alumina modified with sodium dodecyl sulfate (SDS) and a new Schiff's base ligand was prepared for the preconcentration of trace uranyl(VI) from water samples. The uranium(VI) was completely eluted with HCl 2 M and determined by a spectrophotometeric method with Arsenazo(111). The preconcentration steps were studied with regard to experimental parameters such as amount of extractant, type, volume and concentration of eluent, pH, flow rate of sample source and tolerance limit of diverse ions on the recovery of uranyl ion. A preconcentration factor more than 200 was achieved and the average recovery of uranyl(VI) was 99.5%. The relative standard deviation was 1.1% for 10 replicate determinations of uranyl(VI) ion in a solution with a concentration of 5 mu g mL(-1). This method was successfully used for the determination of spiked uranium in natural water samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [41] Copper (II) ion selective liquid membrane electrode based on new Schiff base carrier
    Sadeghi, S
    Vardini, MT
    Naeimi, H
    ANNALI DI CHIMICA, 2006, 96 (1-2) : 65 - 74
  • [42] Highly sensitive and selective detection of dopamine using overoxidized polypyrrole/sodium dodecyl sulfate-modified carbon nanotube electrodes
    Eom, Gayoung
    Oh, Chaerin
    Moon, Jeong
    Kim, Hyojung
    Kim, Mi Kyung
    Kim, Kiup
    Seo, Ji-Won
    Kang, Taejoon
    Lee, Hyunjoo J.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [43] The synthesis of a new thiophene-derivative Schiff's base and its use in preparation of copper-ion selective electrodes
    Poursaberi, T
    Hajiagha-Babaei, L
    Yousefi, M
    Rouhani, S
    Shamsipur, M
    Kargar-Razi, M
    Moghimi, A
    Aghabozorg, H
    Ganjali, MR
    ELECTROANALYSIS, 2001, 13 (18) : 1513 - 1517
  • [44] Novel copper(II)-selective sensor based on a new hexadentates Schiff's base
    Ganjali, MR
    Emami, M
    Salavati-Niasari, M
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2002, 23 (10) : 1394 - 1398
  • [45] A New Lead(II)-Selective PVC-Coated Graphite Rod Electrode Based on a Schiff Base Complex
    Hassan A. Arida
    Sohair A. El-Reefy
    Abeer M. El-Saied
    Analytical Sciences, 2003, 19 : 687 - 690
  • [46] A new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex
    Arida, HA
    El-Reefy, SA
    El-Saied, AM
    ANALYTICAL SCIENCES, 2003, 19 (05) : 687 - 690
  • [47] A new electrochemical method for the determination of trace molybdenum(VI) using carbon paste electrode modified with sodium dodecyl sulfate
    Deng, Pei-hong
    Feng, Yong-lan
    Fei, Jun-jie
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (02) : 367 - 373
  • [48] Thermal and mechanical properties and water absorption of sodium dodecyl sulfate-modified soy protein (11S)
    Zhong, ZK
    Sun, XS
    JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 81 (01) : 166 - 175
  • [50] Interactions between poly(acrylic acid) and sodium dodecyl sulfate: Isothermal titration calorimetric and surfactant ion-selective electrode studies
    Wang, C
    Tam, KC
    JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (11): : 5156 - 5161