2x2 Oversampling in Digital Radiography Imaging for CsI-based Scintillator Detectors

被引:0
|
作者
Kim, Dong Sik [1 ]
Kim, Eun [2 ]
Lee, Eunae [1 ]
Shin, Choul Woo [2 ]
机构
[1] Hankuk Univ Foreign Studies, Yongin, Gyeonggi Do, South Korea
[2] DRTECH Co, Seongnam Si, Gyeonggi Do, South Korea
关键词
Anti-aliasing filtering; detective quantum efficiency (DQE); oversampling; radiography detector; oversampling radiography imaging; QUALITY CHARACTERIZATION;
D O I
10.1117/12.2253874
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to efficiently conduct the anti-aliasing filtering in digital radiography imaging, the oversampling scheme using an oversampling detector, in which the sampling frequency is higher than that of the desired detector, is considered in this paper. Instead of using difficult analog anti-aliasing filters, digital anti-aliasing filters are applied to the oversampled data and then their downsampling enables acquiring the desired x-ray images. Supposing an ideal anti-aliasing filtering, the detective quantum efficiency (DQE) performance of the desired detector can be close to that of the oversampling detector since the overlap of the adjacent noise aliases can be minimized while maintaining the frequency amplitude response for the fundamental frequency range. In this paper, a 2 x 2 oversampling is conducted for the desired pixel pitch of 152 mu m/pixel and various filters are tested for anti-aliasing filtering. It is shown that securing an enough transition band is important to avoid the ringing artifacts even though the anti-aliasing performance deteriorates due to the wide transition band. From an experiment using a CsI(Tl)-based detector, the aliasing artifact problem is alleviated and a DQE improvement of 0.1 is achieved at 2.5 lp/mm from the oversampling radiography imaging over the binning scheme.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Experimental comparison of 2x2 and 2x4 patterned microgrid polarimetric imaging cameras
    Hirakawa, Keigo
    LeMaster, Daniel A.
    Raffoul, Joseph N.
    Chenault, David B.
    Crandall, David G.
    Pezzaniti, J. Larry
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING XVI, 2024, 13050
  • [22] Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors
    Schieber, M
    Hermon, H
    Zentai, G
    Partain, L
    Street, RA
    Gilboa, H
    RADIOLOGY, 2001, 221 : 464 - 464
  • [23] Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors
    Gilboa, H
    Zuck, A
    Dagan, O
    Vilensky, A
    Breen, BN
    Taieb, A
    Reisman, B
    Hermon, H
    Zentai, G
    Partain, L
    Street, R
    Ready, S
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 315 - 325
  • [24] ARCHITECTURE OF CROSSTALK-REDUCED DIGITAL OPTICAL 2X2 SWITCH (CRDOS)
    NOLTING, HP
    GRAVERT, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (11) : 1294 - 1296
  • [25] Detective quantum efficiency of a CsI:Tl scintillator based scanning slot x-ray detector for digital mammography
    Jing, ZX
    Huda, W
    Walker, JK
    Choi, WY
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 583 - 591
  • [26] A TRANSPUTER-BASED LIST MODE PARALLEL SYSTEM FOR DIGITAL RADIOGRAPHY WITH 2D SILICON DETECTORS
    CONTI, M
    DELGUERRA, A
    MAZZEO, A
    MAZZOCCA, N
    RUSSO, P
    RUSSO, S
    SCARLATELLA, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 996 - 1000
  • [27] Design of 2x2 Silicon TE-polarization Digital Optical Switch (DOS) Based on Adiabatic Coupler
    Gong, Yuan-Hao
    Liu, Lei
    Chang, Li-Min
    Li, Zhi-Yong
    Tan, Man-Qing
    Yu, Yu-De
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,
  • [28] A MEDIPIX2-based imaging system for digital mammography with silicon pixel detectors
    Bisogni, MG
    Delogu, P
    Fantacci, ME
    Mettivier, G
    Montesi, MC
    Novelli, M
    Quattrocchi, M
    Rosso, V
    Russo, P
    Stefanini, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1509 - 1512
  • [29] A Medipix2-based imaging system for digital mammography with silicon pixel detectors
    Bisogni, MG
    Delogu, P
    Fantacci, ME
    Mettivier, G
    Montesi, MC
    Novelli, M
    Quattrocchi, M
    Rosso, V
    Russo, P
    Stefanini, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3081 - 3085
  • [30] A 2x2 MEMS optical switch based on piezoelectric actuation
    Barua, Bappi
    Nayim, Hasan
    Bhuiyan, Mahmud Abdul Matin
    ICECE 2006: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, 2006, : 52 - +