Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis

被引:1
|
作者
Shetty, Gautam [1 ,2 ]
Khairkar, Shruti [3 ]
机构
[1] Knee & Orthopaed Clin, Mumbai, Maharashtra, India
[2] AIMD Res, Mumbai, Maharashtra, India
[3] Indian Inst Technol, Dept Mech Engn, Mumbai, Maharashtra, India
关键词
Contact pressure; Finite-element analysis; Attune total knee replacement; Malalignment; Activities of daily living; POST-CAM DESIGN; TIBIAL COMPONENT; CONTACT STRESS; ARTHROPLASTY; FAILURE;
D O I
10.1016/j.jor.2021.07.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare contact stresses between Attune (R) and PFC Sigma (R) total knee arthroplasty (TKA) implants in the presence of knee malalignment. Methods: Maximum contact stress after finite element analysis were compared during standing, walking, and stair climbing in 0 degrees, 2.5 degrees and 5 degrees varus/valgus knee alignments. Results: The percentage increase in contact stress was highest during walking with PFC Sigma (R) in 5 degrees yams (238.5%), standing with Attune (R) in 5 degrees valgus (127.2%), and standing with Attune (R) in 2.5 degrees valgus (107.8%). Conclusion: The newer Attune (R) design may be associated with higher maximum contact stresses and increased risk of wear and implant failure.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 17 条
  • [11] Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis
    Alshewaier, Shady A.
    Sikkandar, Mohamed Yacin
    Almakrami, Ali Ahmed Ali
    Begum, S. Sabarunisha
    Alassaf, Ahmad
    Almohimeed, Ibrahim
    Sundaram, S. Meenatchi
    Poojary, Dheeraj
    Sudharsan, Natteri M.
    Ng, Eddie Y. K.
    PLOS ONE, 2025, 20 (02):
  • [12] More Anterior in vivo Contact Position in Patients With Fixed-Bearing Unicompartmental Knee Arthroplasty During Daily Activities Than in vitro Wear Simulator
    Dai, Huiyong
    Zheng, Nan
    Zou, Diyang
    Zhu, Zhemin
    Liow, Ming Han Lincoln
    Tsai, Tsung-Yuan
    Wang, Qi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [13] Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: In vivo fluoroscopic analysis during activities of daily living
    Fantozzi, Silvia
    Catani, Fabio
    Ensini, Andrea
    Leardini, Alberto
    Giannini, Sandro
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (12) : 2222 - 2229
  • [14] No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial
    Joicemar Tarouco Amaro
    Gustavo Gonçalves Arliani
    Diego Costa Astur
    Pedro Debieux
    Camila Cohen Kaleka
    Moises Cohen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1692 - 1696
  • [15] No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial
    Amaro, Joicemar Tarouco
    Arliani, Gustavo Goncalves
    Astur, Diego Costa
    Debieux, Pedro
    Kaleka, Camila Cohen
    Cohen, Moises
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) : 1692 - 1696
  • [16] The effect of malalignment on proximal tibial strain in fixed-bearing unicompartmental knee arthroplasty A COMPARISON BETWEEN METAL-BACKED AND ALL-POLYETHYLENE COMPONENTS USING A VALIDATED FINITE ELEMENT MODEL
    Danese, I
    Pankaj, P.
    Scott, C. E. H.
    BONE & JOINT RESEARCH, 2019, 8 (02): : 55 - 64
  • [17] In vivo kinematics of knee replacement during daily living activities: Condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses
    Belvedere, Claudio
    Leardini, Alberto
    Catani, Fabio
    Pianigiani, Silvia
    Innocenti, Bernardo
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (07) : 1396 - 1403