Analysis and detection of turn-to-turn short circuit fault in a permanent magnet Vernier generator based on modified winding function

被引:9
|
作者
Arianborna, MohammadHossein [1 ]
Faiz, Jawad [1 ]
Ghods, Mehrage [1 ]
Bazrafshan, Mohammad [1 ]
机构
[1] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Ctr Excellence Appl Electromagnet Syst, Tehran, Iran
关键词
linear machines; modified winding function generator; permanent magnet Vernier turn-turn short circuit fault; Vernier generator; SYNCHRONOUS MACHINE; MOTORS; PMSM; ECCENTRICITY;
D O I
10.1049/elp2.12127
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Operation of Vernier machines is based on flux modulation. They have some advantages including maintaining the rated torque in motor applications and the rated output power in generator applications at low speeds, high torque density and relatively low torque ripple due to their magnetic gear property and fault-tolerance. In recent years, the motor with various topologies has been developed for different applications. Therefore, analysing and monitoring different faults is essential in the design and implementation stages. This study has two main purposes. First, to introduce an accurate frequency index independent of load variations for detecting the turn-to-turn short circuit (TTSC) faults in the stator windings of a permanent magnet Vernier machine. Second, modelling the machine in a healthy condition and in the presence of TTSC faults to investigate its effect on machine performance and output characteristics. An analytical model is presented using the modified winding function theory under the TTSC fault by taking into account the effect of stator slots which enhances the accuracy of the air-gap permeance function estimation. In the process of calculating the fault index, frequency components of the output characteristics of the machine are obtained from the mathematical equations of the magnetic field. It is shown that the proposed indicators are robust against load variations.
引用
收藏
页码:1630 / 1647
页数:18
相关论文
共 50 条
  • [21] Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
    Cintron-Rivera, Jorge G.
    Foste, Shanelle N.
    Strangas, Elias G.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) : 465 - 475
  • [22] Performance Evaluation of Permanent Magnet Vernier Generator Based on Modified Winding Function Method
    Ghods, M.
    Nasiri-Gheidari, Z.
    Tootoonchian, F.
    Oraee, A.
    26TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE 2018), 2018, : 1107 - 1112
  • [23] Simulation of a Turn-to-Turn Short Circuit in an Induction-Motor Rotor Winding
    Lavrenov E.O.
    Vilberger M.E.
    Temlyakova Z.S.
    Morozov P.V.
    Temlyakov A.A.
    Russian Electrical Engineering, 2022, 93 (05) : 326 - 330
  • [24] The Detection of an Inter-Turn Short-Circuit Fault in a Brushless Permanent Magnet Motor with Different Winding Configurations
    Korkosz, Mariusz
    Prokop, Jan
    Ryllo, Karol
    ENERGIES, 2024, 17 (24)
  • [25] Fault Diagnose of Rotor Winding Inter Turn Short Circuit in Generator
    Xiao, Haiyan
    Wang, Xuewu
    Chen, Dengfeng
    MECHATRONICS AND INDUSTRIAL INFORMATICS, PTS 1-4, 2013, 321-324 : 1290 - +
  • [26] Method for measuring AC impedance of generator rotor and effects on decision of turn-to-turn short circuit fault
    Yang, H.
    Zhao, H.
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2001, 25 (11):
  • [27] Turn-to-Turn Short Circuit Fault Localization in Transformer Winding via Image Processing and Deep Learning Method
    Moradzadeh, Arash
    Moayyed, Hamed
    Mohammadi-Ivatloo, Behnam
    Gharehpetian, G. B.
    Aguiar, A. Pedro
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (07) : 4417 - 4426
  • [28] Research on the application of transformer vibration model in the detection of turn-to-turn short-circuit fault
    Wu, Xutao
    Yan, Zhenhua
    Ji, Shengchang
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1332 - +
  • [29] Diagnostics System Improvement of Turn-to-Turn Short Circuits of Synchronous Generator Rotor Winding
    Polishchuk, V., I
    Gnetova, D. A.
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [30] Analysis of primary side turn-to-turn short circuit fault in PT at the generator outlet and diagnosis using CSSA-GMM
    Wei, Yang
    Li, Chen
    Ai, Yuangao
    Shen, Hongwan
    Zeng, Shai
    Sun, Yue
    Frontiers in Energy Research, 2024, 12