Gastric emptying of solids in children: reference values for the 13C-octanoic acid breath test

被引:18
|
作者
Hauser, B. [1 ]
Roelants, M. [2 ]
De Schepper, J. [1 ]
Veereman, G. [1 ]
Caveliers, V. [3 ]
Devreker, T. [1 ]
De Greef, E. [1 ]
Vandenplas, Y. [1 ]
机构
[1] Vrije Univ Brussel, Univ Kinderziekenhuis Brussel, Dept Paediat, Brussels, Belgium
[2] Katholieke Univ Leuven, Dept Publ Hlth & Primary Care, Leuven, Belgium
[3] Univ Ziekenhuis Brussel, Dept Nucl Med, Brussels, Belgium
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2016年 / 28卷 / 10期
关键词
C-13-octanoic acid breath test; children; gastric emptying; non-dispersive infrared spectrometry; normal values; scintigraphy; solids; HEALTHY-SUBJECTS; TIME; ADULTS; AGE; SCINTIGRAPHY; DISEASE; WEIGHT;
D O I
10.1111/nmo.12845
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background(99m)Technetium scintigraphy ((TS)-T-99m) is the gold standard' for measuring gastric emptying (GE), but it is associated with a radiation exposure. For this reason, the C-13-octanoic acid breath test (C-13-OBT) was developed for measuring GE of solids. The objective of this study was to determine normal values for gastric half-emptying time (t(1/2)GE) of solids in healthy children. MethodsGastric emptying of a standardized solid test meal consisting of a pancake evaluated with (TS)-T-99m and C-13-OBT was compared in 22 children aged between 1 and 15 years with upper gastrointestinal symptoms. Subsequently, the C-13-OBT was used to determine normal values for GE of the same solid test meal in 120 healthy children aged between 1 and 17 years. Key ResultsThe results showed a significant correlation (r = 0.748, p = 0.0001) between t(1/2)GE measured with both techniques in the group of children with upper gastrointestinal symptoms. In the group of healthy children, mean t(1/2)GE was 157.7 54.0 min (range 71-415 min), but t(1/2)GE decreased with age between 1 and 10 years and remained stable afterward. There was no influence of gender, weight, height, body mass index, and body surface area on t(1/2)GE. Conclusions & InferencesNormal values for GE of solids measured with the C-13-OBT using a standardized methodology were determined in healthy children. We propose to use this method and corresponding reference ranges to study GE of solids in children with gastrointestinal problems.
引用
收藏
页码:1480 / 1487
页数:8
相关论文
共 50 条
  • [41] Delayed gastric emptying in ventilated critically ill patients:: Measurement by 13C-octanoic acid breath test
    Ritz, MA
    Fraser, R
    Edwards, N
    Di Matteo, AC
    Chapman, M
    Butler, R
    Cmielewski, P
    Tournadre, JP
    Davidson, G
    Dent, J
    CRITICAL CARE MEDICINE, 2001, 29 (09) : 1744 - 1749
  • [42] Delayed gastric emptying determined using the 13C-octanoic acid breath test in patients with systemic sclerosis
    Marie, Isabelle
    Gourcerol, Guillaume
    Leroi, Anne-Marie
    Menard, Jean-Francois
    Levesque, Herve
    Ducrotte, Philippe
    ARTHRITIS AND RHEUMATISM, 2012, 64 (07): : 2346 - 2355
  • [43] Quantitative detection of atropine-delayed gastric emptying in the horse by the 13C-octanoic acid breath test
    Sutton, DGM
    Bahr, A
    Preston, T
    Cohen, ND
    Love, S
    Roussel, AJ
    EQUINE VETERINARY JOURNAL, 2002, 34 (05) : 479 - 485
  • [44] The 13C-octanoic acid breath test:: validation of a new noninvasive method of measuring gastric emptying in rats
    Schoonjans, R
    Van Vlem, B
    Van Heddeghem, N
    Vandamme, W
    Vanholder, R
    Lameire, N
    Lefebvre, R
    De Vos, M
    NEUROGASTROENTEROLOGY AND MOTILITY, 2002, 14 (03): : 287 - 293
  • [45] Standardization of the testmeal for the 13C octanoic acid breath test to measure gastric emptying of solids in children.
    Van Den Driessche, M
    Ghoos, Y
    Veereman-Wauters, G
    GASTROENTEROLOGY, 1998, 114 (04) : A851 - A851
  • [46] Further validation of the [13C]octanoic acid breath test for gastric emptying of solids.
    Drewe, J
    Hildebrand, P
    Descloux, L
    Beglinger, C
    GASTROENTEROLOGY, 1998, 114 (04) : A745 - A745
  • [47] Gastric emptying of a solid meal starts during meal ingestion:: Combined study using 13C-octanoic acid breath test and Doppler ultrasonography -: Absence of a lag phase in 13C-octanoic acid breath test
    Minderhoud, IM
    Mundt, MW
    Roelofs, JMM
    Samsom, M
    DIGESTION, 2004, 70 (01) : 55 - 60
  • [48] Comparison of two mathematical programmes in evaluation of the 13C-octanoic acid breath test for gastric emptying in healthy volunteers
    Douda, T
    Bures, J
    Kopacova, M
    Vorisek, V
    Bukac, J
    Rejchrt, S
    Siroky, M
    Zivny, P
    Palicka, V
    GASTROENTEROLOGY, 2001, 120 (05) : A466 - A466
  • [49] Measuring gastric emptying with the 13C octanoic acid breath test in infants and children
    Veereman-Wauters, G
    GUT, 1998, 43 : S29 - S30
  • [50] Evaluation of gastric emptying measured with the 13C-octanoic acid breath test in patients with functional dyspepsia comparison with ultrasonography
    Aoki, S
    Haruma, K
    Kusunoki, H
    Hata, J
    Hara, M
    Yoshida, S
    Tanaka, S
    Chayama, K
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2002, 37 (06) : 662 - 666