Effect of Control-Structure Interaction Using Torsional Servomotor for Active Tuned Mass Damper Control System

被引:11
|
作者
Yan, Xiao [1 ,2 ,3 ]
Xu, Zhao-Dong [1 ,2 ,3 ,4 ]
Shi, Qing-Xuan [1 ,2 ,3 ]
Dai, Jun [4 ]
机构
[1] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Coll Civil Engn, Xian 710055, Peoples R China
[3] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
[4] Southeast Univ, China Pakistan Belt & Rd Joint Lab Smart Disaster, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Active control; control-structure interaction; torsional servomotor; electromechanical relationship; DRIVER;
D O I
10.1142/S0219455422501425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The control-structure interaction (CSI) affects the performance and robustness of protective structures in active control system, and it is important to consider the CSI effect to achieve high performance in structural vibration control. In this paper, the electro-mechanical model of the torsional servomotor is derived by establishing dynamic voltage equilibrium equation. Three different active control models (non-CSI, reduced-order CSI, and higher-order CSI model) which considering different accuracy requirements of the electro-mechanical relationship are established to investigate the influence of the CSI on active tuned mass damper (ATMD) control system. The frequency- and time-domain responses of a three-story steel frame structure during different excitations are investigated, and as a comparison, the responses of the uncontrolled and tuned mass damper (TMD) control system are also studied. It can be concluded that the control performance of the active control system is reduced due to the CSI effect, especially at resonance frequency region of the structure (around 2.7Hz, 8.2 Hz, and 13.2 Hz). The input voltage, velocity of the top floor, velocity of active mass, and higher-order of control forces have an important influence on the servomotor output control force. Furthermore, it can be found that, to achieve the same control effect, the required control voltage has been significantly increased due to the CSI effect.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Effect of Soil and Structure Nonlinear Interaction on the Efficiency of Tuned Mass Damper
    Masaeli, Hamid
    Panahi, Mehdi
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (10): : 2474 - 2490
  • [42] CONTROL OF NONLINEAR VIBRATIONS IN CABLE-STAYED BRIDGES BY USING ACTIVE TUNED MASS DAMPER
    ABDELROHMAN, M
    ASKAR, H
    JOURNAL OF THE UNIVERSITY OF KUWAIT-SCIENCE, 1995, 22 (01): : 12 - 23
  • [43] Torsional Vibration Control of High-rise Building with Large Local Space by Using Tuned Mass Damper
    Zhao, Bin
    Gao, Hui
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 3066 - +
  • [44] Decentralized control of vibrations in wind turbine blades using multiple active tuned mass damper
    Cong, Cong
    Yang, Bing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (01): : 179 - 184
  • [45] A composite control scheme for electromagnetic active mass damper against control-structure-interaction effects
    Yao, Hongcan
    Tan, Ping
    Zhou, Huimeng
    Zhou, Fulin
    ENGINEERING STRUCTURES, 2023, 281
  • [46] Stability control of floating wind turbines with tuned mass damper structure
    Mu, Anle
    Wang, Chao
    Liu, Hongzhao
    Zhang, Minghong
    Zhang, Yulong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (35): : 89 - 94
  • [47] Tuned Mass Damper for Rail Noise Control
    Ho, Wilson
    Wong, Banting
    England, David
    NOISE AND VIBRATION MITIGATION FOR RAIL TRANSPORTATION SYSTEMS, 2012, 118 : 89 - +
  • [48] Semi-active control of walking-induced vibrations in bridges using adaptive tuned mass damper considering human-structure-interaction
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2021, 244
  • [49] ROLE OF CONTROL-STRUCTURE INTERACTION IN PROTECTIVE SYSTEM-DESIGN
    DYKE, SJ
    SPENCER, BF
    QUAST, P
    SAIN, MK
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1995, 121 (02): : 322 - 338
  • [50] Optimum control design of active tuned mass damper for structures subjected to earthquakes
    Li, Chun-Xiang
    Teng, Nian-Guan
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2004, 38 (06): : 987 - 991