Response of MV-connected Doubly-Fed Induction Generator Wind Turbines and CHP-plants to Grid Disturbances

被引:0
|
作者
Karaliolios, P. [1 ]
Slootweg, J. G. [1 ]
Kling, W. L. [1 ]
机构
[1] Eindhoven Univ Technol, Elect Energy Syst Grp, NL-5600 MB Eindhoven, Netherlands
来源
IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010 | 2010年
关键词
Decentralized Generation; Fault Ride-Through; Short-Circuit contribution; CHP-plant; Doubly-Fed Induction Generator;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Notwithstanding the positive environmental impact, the increasing penetration of Distributed Generation (DG) units connected to the distribution network raises new topics concerning the expected response of these during outages. Grid disturbances especially at the transmission level can cause the unwanted disconnection of large amounts of DG, leading to undesired power imbalances causing line overloadings and/or voltage and frequency instability. This paper examines how transmission network faults can affect the operation of DG units connected on to the distribution network, how these units currently contribute to the voltage support and what are the consequences of actual and possible Fault Ride-Through (FRT) behaviors.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Diagnosis of the Doubly-Fed Induction Generator of a Wind Turbine
    Bennouna, O.
    Heraud, N.
    Camblong, H.
    Rodriguez, M.
    WIND ENGINEERING, 2005, 29 (05) : 431 - 447
  • [32] A control strategy for doubly-fed induction generator wind turbines under asymmetrical grid voltage conditions caused by faults
    Wang, Hongsheng
    Zhang, Wei
    Hu, Jiabing
    He, Yikang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (04): : 97 - 102
  • [33] Study on Harmonic Resonance and Grid-Connected Control Technology of Doubly-Fed Wind Turbines
    Xu, Jin
    Chen, Haiyun
    Zhao, Wanming
    Li, Qian
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2019, 26 (05): : 1499 - 1504
  • [34] Doubly fed induction generator systems for wind turbines
    Müller, S
    Deicke, M
    De Doncker, RW
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) : 26 - 33
  • [35] A grid-connected control strategy for doubly-fed wind turbines for new power systems
    Tan Z.
    Wen X.
    Yang T.
    Zeng P.
    Hu M.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (03): : 181 - 187
  • [36] Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances
    Holdsworth, L
    Wu, XG
    Ekanayake, JB
    Jenkins, N
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) : 343 - 352
  • [37] Analysis of Bearing Currents in Doubly-Fed Induction Wind Turbines
    Liu R.
    Ren X.
    Chen J.
    Liu, Ruifang (rfliu@bjtu.edu.cn), 2018, China Machine Press (33): : 4517 - 4525
  • [38] Calculating Steady-State Operating Conditions for Doubly-Fed Induction Generator Wind Turbines
    Medina Padron, Jose Fernando
    Feijoo Lorenzo, Andres Elias
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (02) : 922 - 928
  • [39] Hybrid fuzzy sliding mode control of a doubly-fed induction generator speed in wind turbines
    Kerboua, Abdelfettah
    Abid, Mohamed
    JOURNAL OF POWER TECHNOLOGIES, 2015, 95 (02): : 126 - 133
  • [40] Reduced order model for grid connected wind turbines with doubly fed induction generators
    Neto, A. Samuel
    Ferreira, S. L. A.
    Arruda, J. P.
    Neves, F. A. S.
    Rosas, P. A. C.
    Cavalcanti, M. C.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2655 - 2660