Monte Carlo and analytical models of neutron detection with organic scintillation detectors

被引:36
|
作者
Pozzi, Sara A.
Flaska, Marek
Enqvist, Andreas
Pazsit, Imre
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[2] Chalmers, Chalmers, Sweden
关键词
MCNP-PoliMi; neutron detection; organic scintillator; pulse height distribution;
D O I
10.1016/j.nima.2007.08.246
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a new technique for the analysis of neutron pulse height distributions generated in an organic scintillation detector. The methodology presented can be applied to techniques such as neutron spectrum unfolding, which have a variety of applications, including nuclear nonproliferation and homeland security. The technique is based on two independent approaches: (i) the use of the MCNP-PoliMi code to simulate neutron detection on an event-by-event basis with the Monte Carlo method and (ii) an analytical approach for neutron slowing down and detection processes. We show that the total neutron pulse height response measured by the organic scintillators is given by the sum of a large number of different neutron histories, each composed of a certain number of neutron scatterings on hydrogen and/or carbon. The relative contributions of each of these histories are described for a cylindrical liquid scintillator BC-501A. Simulations and measurements of neutron pulse height distributions are essential for neutron spectrum unfolding procedures. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:629 / 637
页数:9
相关论文
共 50 条
  • [11] EXPERIMENTAL AND MONTE CARLO INVESTIGATIONS OF BCF-12 SMALL-AREA PLASTIC SCINTILLATION DETECTORS FOR NEUTRON PINHOLE CAMERA
    Bielecki, J.
    Drozdowicz, K.
    Dworak, D.
    Igielski, A.
    Janik, W.
    Kulinska, A.
    Marciniak, L.
    Scholz, M.
    Turzanski, M.
    Wiacek, U.
    Woznicka, U.
    Wojcik-Gargula, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 427 - 431
  • [12] MSX - A Monte-Carlo code for neutron efficiency calculations for large volume Gd-loaded liquid scintillation detectors
    Trzcinski, A
    Zwieglinski, B
    ACTA PHYSICA POLONICA B, 1997, 28 (1-2): : 145 - 148
  • [13] Monte Carlo simulations of the sensitivity of scintillating-film neutron detectors
    Northwest Institute of Nuclear Technology, Xi'an 710024, China
    Qinghua Daxue Xuebao, 2007, SUPPL. 1 (963-966):
  • [14] NEUTRON-PROTON SCATTERING USING ORGANIC CRYSTAL SCINTILLATION DETECTORS
    REMLEY, ME
    JENTSCHKE, WK
    KRUGER, PG
    PHYSICAL REVIEW, 1952, 88 (01): : 162 - 162
  • [15] NEUTRON-PROTON SCATTERING USING ORGANIC CRYSTAL SCINTILLATION DETECTORS
    REMLEY, ME
    JENTSCHKE, WK
    KRUGER, PG
    PHYSICAL REVIEW, 1953, 89 (06): : 1194 - 1198
  • [16] Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements
    van der Graaf, E. R.
    Limburg, J.
    Koomans, R. L.
    Tijs, M.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2011, 102 (03) : 270 - 282
  • [17] MONTE-CARLO SIMULATION OF GAMMA-RAY DETECTORS USING SCINTILLATION FIBERS
    CHANEY, RC
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 18 - 26
  • [18] Comparing analytical and Monte Carlo optical diffusion models in phosphor-based X-ray detectors
    Kalyvas, N.
    Liaparinos, P.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [19] Fast neutron detection with pressurized 4He scintillation detectors
    Chandra, R.
    Davatz, G.
    Friederich, H.
    Gendotti, U.
    Murer, D.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [20] Neutron and Gamma Sensitivities of Self-Powered Detectors: Monte Carlo Modelling
    Vermeeren, Ludo
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,