R-152a as an alternative refrigerant to R-134a in domestic refrigerators: An experimental analysis

被引:34
|
作者
Maiorino, Angelo [1 ,4 ]
Aprea, Ciro [1 ,3 ]
del Duca, Manuel Gesu [1 ]
Llopis, Rodrigo [2 ,4 ]
Sanchez, Daniel [2 ,4 ]
Cabello, Ramon [2 ]
机构
[1] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo 2 132, I-84084 Fisciano, SA, Italy
[2] Univ Jaume 1, Dept Mech Engn & Construt, Campus Riu Sec S-N, E-12071 Castellon De La Plana, Spain
[3] IIR IIF Commiss E2, Paris, France
[4] IIR IIF, Paris, France
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 96卷
关键词
R-134a; R-152a; Domestic refrigeration; Capillary tube; Low GWP; Energy analysis; R152A;
D O I
10.1016/j.ijrefrig.2018.09.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
Among all sectors of refrigeration, one of the most affected by the latest international regulations is the domestic refrigeration. Although for it has been suggested some solutions, such as the construction of household refrigerator operating with the hydrocarbons, there remains the need to find a substitute for R-134a. With the aim of finding a simple implementation solution, in the present work, it is reported an experimental investigation carried out on a domestic no-frost refrigerator designed and built to operate with R-134a and for which a drop-in with R-152a has been realised. Different tests have been performed with the aim to identify the right charge of R-152a too. In line with the standard ISO 15502:2005 (2005), pull-down and 24 h energy consumption experiments have been run to evaluate the performance of R-152a as the drop-in replacement of R-134a in a domestic refrigerator. Also, a theoretical model has been proposed with the aim to give support to the observed energy change. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:106 / 116
页数:11
相关论文