The prevalence and significance of renal perfusion defects in early kidney transplants quantified using 3D contrast enhanced ultrasound (CEUS)

被引:15
|
作者
Ben Stenberg [1 ]
Wilkinson, M. [2 ]
Elliott, S. [1 ]
Caplan, N. [2 ]
机构
[1] Newcastle Upon Tyne Hosp NHS Trust, Freeman Hosp, Newcastle Upon Tyne, Tyne & Wear, England
[2] Northumbria Univ, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Contrast enhanced ultrasound; Three-dimensional ultrasound; Kidney transplant; Perfusion defect; Kidney function; DELAYED GRAFT FUNCTION; VOLUME MEASUREMENT; ACCURACY;
D O I
10.1007/s00330-017-4871-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Vascular complications are one of the most common causes of early kidney transplant dysfunction. Contrast enhanced ultrasound increases sensitivity to vascular changes. The aim of this study was to assess the prevalence and size of vascular abnormalities in early renal transplants using 3D CEUS and the significance of perfusion defects on renal function. Methods Ninety-nine renal transplant patients underwent 3D CEUS after surgery to quantify perfusion defects as percentage total renal volume (TRV). Serum creatinine and estimated glomerular filtration rate (eGFR) were recorded up to 3 months post-surgery. Results Twenty participants had focal perfusion defects (0.243% TRV). There was a meaningful difference in patients with perfusion defects in eGFR at 1 month (90% CI 2.7-19.2 mL/min/1.73 m(2)) and 3 months (90% CI 1.9-19.6 mL/min/1.73 m(2)) and creatinine at 3 months (90% CI-56 - -8 mu mol/L) using a predetermined clinical threshold. Perfusion defect size correlated well with both serum creatinine and eGFR at 3 months (R = 0.80, p <= 0.000 and 0.58, p = 0.038). No correlation was seen prior to 3 months. Conclusions Perfusion defects in kidney transplants were more common than expected and were highly likely to reduce renal function at 1-3 months, and the size of the defect affected the degree of functional change at 3 months.
引用
收藏
页码:4525 / 4531
页数:7
相关论文
共 50 条
  • [41] Perfusion Patterns of Peripheral Pulmonary Metastasis Using Contrast-Enhanced Ultrasound (CEUS) and Their Correlation with Immunohistochemically Detected Vascularization Pattern
    Kroenig, Johannes
    Goerg, Christian
    Prosch, Helmut
    Von Schumann, Lara
    Westhoff, Christina C.
    Alhyari, Amjad
    Koenig, Felix R. M.
    Findeisen, Hajo
    Zadeh, Ehsan Safai
    CANCERS, 2024, 16 (19)
  • [42] Quantification of dynamic contrast-enhanced ultrasound (CEUS) in non-cystic breast lesions using external perfusion software
    Jung, Ernst Michael
    Jung, Friedrich
    Stroszczynski, Christian
    Wiesinger, Isabel
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] Quantification of dynamic contrast-enhanced ultrasound (CEUS) in non-cystic breast lesions using external perfusion software
    Ernst Michael Jung
    Friedrich Jung
    Christian Stroszczynski
    Isabel Wiesinger
    Scientific Reports, 11
  • [44] ROBUST LUMEN SEGMENTATION IN 3D CONTRAST ENHANCED ULTRASOUND IMAGES
    Cao, Kunlin
    Padfield, Dirk
    Dentinger, Aaron
    Wallace, Kirk
    Mills, David
    2015 IEEE 12TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2015, : 659 - 662
  • [45] Contrast-Enhanced Ultrasound for Assessing Renal Perfusion Impairment and Predicting Acute Kidney Injury to Chronic Kidney Disease Progression
    Cao, Wei
    Cui, Shuang
    Yang, Li
    Wu, Chunyi
    Liu, Jian
    Yang, Fang
    Liu, Youhua
    Bin, Jianping
    Hou, Fan Fan
    ANTIOXIDANTS & REDOX SIGNALING, 2017, 27 (17) : 1397 - 1411
  • [46] Contrast-enhanced ultrasound with SonoVue could accurately assess the renal microvascular perfusion in diabetic kidney damage
    Ma, Fang
    Cang, Yanqin
    Zhao, Baozhen
    Liu, Yuanyuan
    Wang, Chaoqing
    Liu, Bo
    Wu, Tianfu
    Song, Yaxiang
    Peng, Ai
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (07) : 2891 - 2898
  • [47] QUANTITATIVE ANALYSIS OF RENAL PERFUSION IN RHABDOMYOLYSIS- INDUCED ACUTE KIDNEY INJURY USING CONTRAST-ENHANCED ULTRASOUND: AN EXPERIMENTAL STUDY
    Zhao, Ping
    LI, Qiuyang
    Wang, Shuo
    Wang, Yiru
    Zhu, Jianing
    Zhu, Lianhua
    Tang, Jie
    Luo, Yukun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (10): : 2110 - 2118
  • [48] Detection of early therapeutic response with dynamic contrast enhanced ultrasound using a perfusion clustering algorithm
    Barrois, Guillaume
    Coron, Alain
    Bridal, S. Lori
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1754 - 1757
  • [49] Long Term Surveillance of Renal Cell Carcinoma Recurrence Following Ablation using 2D and 3D Contrast-Enhanced Ultrasound
    Calio, Brian P.
    Lyshchik, Andrej
    Li, Jingzhi
    Stanczak, Maria
    Shaw, Collette M.
    Adamo, Robert
    Liu, Ji-Bin
    Forsberg, Flemming
    Lallas, Costas D.
    Trabulsi, Edouard J.
    Eisenbrey, John R.
    UROLOGY, 2018, 121 : 189 - 195
  • [50] Long Term Surveillance of Renal Cell Carcinoma Recurrence Following Ablation using 2D and 3D Contrast-Enhanced Ultrasound
    Huddleston, Patrick A.
    Gardner, Thomas A.
    UROLOGY, 2018, 121 : 195 - 196