摘要
This study describes noninvasive noncontact methods to acquire and analyze functional information from the skin. Multispectral images at several selected wavelengths in the visible and near infrared region are collected and used in mathematical methods to calculate concentrations of different chromophores in the epidermis and dermis of the skin. This is based on the continuous wave Near Infrared Spectroscopy method, which is a well known non-invasive technique for measuring oxygenation changes in the brain and in muscle tissue. Concentration changes of hemoglobin (dO(2)Hb, dHHb and dtHb) can be calculated from light attenuations using the modified Lambert Beer equation. We applied this technique on multi-spectral images taken from the skin surface using different algorithms for calculating changes in O(2)Hb, HHb and tHb. In clinical settings, the imaging of local oxygenation variations and/or blood perfusion in the skin can be useful for e. g. detection of skin cancer, detection of early inflammation, checking the level of peripheral nerve block anesthesia, study of wound healing and tissue viability by skin flap transplantations. Images from the skin are obtained with a multi-spectral imaging system consisting of a 12-bit CCD camera in combination with a Liquid Crystal Tunable Filter. The skin is illuminated with either a broad band light source or a tunable multi wavelength LED light source. A polarization filter is used to block the direct reflected light. The collected multi-spectral imaging data are images of the skin surface radiance; each pixel contains either the full spectrum (420 - 730 nm) or a set of selected wavelengths. These images were converted to reflectance spectra. The algorithms were validated during skin oxygen saturation changes induced by temporary arm clamping and applied to some clinical examples. The initial results with the multi-spectral skin imaging system show good results for detecting dynamic changes in oxygen concentration. However, the optimal algorithm needs to be determined. Multi-spectral skin imaging shows to be a promising technique for various clinical applications were the local distribution of oxygenation is of major importance.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] An upgraded camera-based imaging system for mapping venous blood oxygenation in human skin tissue
    Li, Jun
    Zhang, Xiao
    Qiu, Lina
    Leotta, Daniel E.
    OPTICS COMMUNICATIONS, 2016, 370 : 276 - 282
  • [32] Analysis of microparticle penetration into human and porcine skin: non-invasive imaging with multiphoton excitation microscopy
    Mulholland, WJ
    Kendall, MAF
    Bellhouse, BJ
    White, N
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 113 - 122
  • [33] Author Correction: Non-invasive multimodal optical coherence and photoacoustic tomography for human skin imaging
    Zhe Chen
    Elisabet Rank
    Kristen M. Meiburger
    Christoph Sinz
    Andreas Hodul
    Edward Zhang
    Erich Hoover
    Micheal Minneman
    Jason Ensher
    Paul C. Beard
    Harald Kittler
    Rainer A. Leitgeb
    Wolfgang Drexler
    Mengyang Liu
    Scientific Reports, 8
  • [34] In vivo multiphoton imaging for non-invasive time course assessment of retinoids effects on human skin
    Tancrede-Bohin, Emmanuelle
    Baldeweck, Therese
    Brizion, Sebastien
    Decenciere, Etienne
    Victorin, Steeve
    Ngo, Blandine
    Raynaud, Edouard
    Souverain, Luc
    Bagot, Martine
    Pena, Ana-Maria
    SKIN RESEARCH AND TECHNOLOGY, 2020, 26 (06) : 794 - 803
  • [35] A Method to Determine Human Skin Heat Capacity Using a Non-Invasive Calorimetric Sensor
    Rodriguez de Rivera, Pedro Jesus
    Rodriguez de Rivera, Miriam
    Socorro, Fabiola
    Rodriguez de Rivera, Manuel
    Marrero Callico, Gustavo
    SENSORS, 2020, 20 (12) : 1 - 19
  • [36] Non-Invasive Hydration Level Estimation in Human Body Using Galvanic Skin Response
    Rizwan, Ali
    Abu Ali, Najah
    Zoha, Ahmed
    Ozturk, Metin
    Alomainy, Akram
    Imran, Muhammad Ali
    Abbasi, Qammer H.
    IEEE SENSORS JOURNAL, 2020, 20 (09) : 4891 - 4900
  • [37] Non-Invasive Skin Cancer Diagnosis Using Hyperspectral Imaging for In-Situ Clinical Support
    Leon, Raquel
    Martinez-Vega, Beatriz
    Fabelo, Himar
    Ortega, Samuel
    Melian, Veronica
    Castano, Irene
    Carretero, Gregorio
    Almeida, Pablo
    Garcia, Aday
    Quevedo, Eduardo
    Hernandez, Javier A.
    Clavo, Bernardino
    Callico, Gustavo M.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06)
  • [38] Detection theory for accurate and non-invasive skin cancer diagnosis using dynamic thermal imaging
    Godoy, Sebastian E.
    Hayat, Majeed M.
    Ramirez, David A.
    Myers, Stephen A.
    Padilla, R. Steven
    Krishna, Sanjay
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (04): : 2301 - 2323
  • [39] Flexible Potentiometric Sensor System for Non-Invasive Determination of Antioxidant Activity of Human Skin: Application for Evaluating the Effectiveness of Phytocosmetic Products
    Tarasov, Aleksey V.
    Khamzina, Ekaterina I.
    Bukharinova, Maria A.
    Stozhko, Natalia Yu.
    CHEMOSENSORS, 2021, 9 (04)
  • [40] Non-invasive postoperative monitoring of pedicled rat skin flap using laser speckle contrast imaging
    Im, Jinhyuck
    Kong, Tae Hoon
    Choi, Jin Sil
    Seo, Young Joon
    Choi, Eun Chang
    Jung, Byungjo
    Kim, Ji-Hoon
    MICROVASCULAR RESEARCH, 2020, 132