Multimodal Registration for Image-Guided EBUS Bronchoscopy

被引:4
|
作者
Zang, Xiaonan [1 ]
Zhao, Wennan [1 ]
Toth, Jennifer [2 ]
Bascom, Rebecca [2 ]
Higgins, William [1 ]
机构
[1] Penn State Univ, Sch Elect Engn & Comp Sci, State Coll, PA 16802 USA
[2] Penn State Milton S Hershey Med Ctr, Hershey, PA 17033 USA
关键词
bronchoscopy; endobronchial ultrasound; image registration; image-guided surgery systems; multimodal imaging; lung cancer; TRANSBRONCHIAL NEEDLE ASPIRATION; PERIPHERAL LUNG LESIONS; ENDOBRONCHIAL ULTRASOUND; DIAGNOSTIC YIELD; VIRTUAL BRONCHOSCOPY; GUIDANCE; SYSTEM; SEGMENTATION; REAL;
D O I
10.3390/jimaging8070189
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The state-of-the-art procedure for examining the lymph nodes in a lung cancer patient involves using an endobronchial ultrasound (EBUS) bronchoscope. The EBUS bronchoscope integrates two modalities into one device: (1) videobronchoscopy, which gives video images of the airway walls; and (2) convex-probe EBUS, which gives 2D fan-shaped views of extraluminal structures situated outside the airways. During the procedure, the physician first employs videobronchoscopy to navigate the device through the airways. Next, upon reaching a given node's approximate vicinity, the physician probes the airway walls using EBUS to localize the node. Due to the fact that lymph nodes lie beyond the airways, EBUS is essential for confirming a node's location. Unfortunately, it is well-documented that EBUS is difficult to use. In addition, while new image-guided bronchoscopy systems provide effective guidance for videobronchoscopic navigation, they offer no assistance for guiding EBUS localization. We propose a method for registering a patient's chest CT scan to live surgical EBUS views, thereby facilitating accurate image-guided EBUS bronchoscopy. The method entails an optimization process that registers CT-based virtual EBUS views to live EBUS probe views. Results using lung cancer patient data show that the method correctly registered 28/28 (100%) lymph nodes scanned by EBUS, with a mean registration time of 3.4 s. In addition, the mean position and direction errors of registered sites were 2.2 mm and 11.8 degrees, respectively. In addition, sensitivity studies show the method's robustness to parameter variations. Lastly, we demonstrate the method's use in an image-guided system designed for guiding both phases of EBUS bronchoscopy.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Multimodal image-guided enzyme/prodrug cancer therapy
    Li, Cong
    Winnard, Paul T., Jr.
    Takagi, Tomoyo
    Artemov, Dmitri
    Bhujwalla, Zaver M.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (47) : 15072 - 15073
  • [32] A multimodal nano agent for image-guided cancer surgery
    Zheng, Jinzi
    Muhanna, Nidal
    De Souza, Raquel
    Wada, Hironobu
    Chan, Harley
    Akens, Margarete K.
    Anayama, Takashi
    Yasufuku, Kazuhiro
    Serra, Stefano
    Irish, Jonathan
    Allen, Christine
    Jaffray, David
    BIOMATERIALS, 2015, 67 : 160 - 168
  • [33] Coaxial electrospray for multimodal imaging and image-guided therapy
    Si, Ting
    Zhang, Leilei
    Li, Guangbin
    Roberts, Cynthia J.
    Jia, Laibing
    Yin, Xiezhen
    Xu, Ronald
    MULTIMODAL BIOMEDICAL IMAGING VII, 2012, 8216
  • [34] Deformable 3D/3D CT-to-digital-tomosynthesis image registration in image-guided bronchoscopy interventions
    Saad F.
    Frysch R.
    Saalfeld S.
    Kellnberger S.
    Schulz J.
    Fahrig R.
    Bhadra K.
    Nürnberger A.
    Rose G.
    Comput. Biol. Med., 2024,
  • [35] Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT)
    Sharma, Shamurailatpam Dayananda
    Dongre, Prabhakar
    Mhatre, Vaibhav
    Heigrujam, Malhotra
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (03) : 311 - 319
  • [36] Automation of image registration and verification for image-guided stereotactic body radiotherapy
    Wang, C
    Shiu, A
    Lii, M
    Chang, E
    MEDICAL PHYSICS, 2005, 32 (06) : 1943 - 1943
  • [37] Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT)
    Shamurailatpam Dayananda Sharma
    Prabhakar Dongre
    Vaibhav Mhatre
    Malhotra Heigrujam
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 311 - 319
  • [38] Multimodal image re-registration via mutual information to account for initial tissue motion during image-guided neurosurgery
    Wu, Z
    Hartov, A
    Paulsen, KD
    Roberts, DW
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1675 - 1678
  • [39] Virtual Radial-Probe Endobronchial Ultrasound for Image-Guided Bronchoscopy
    Zhao, Wennan
    Bascom, Rebecca
    Toth, Jennifer
    Higgins, William E.
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [40] Technician-Free Image-Guided Bronchoscopy System: A Human Study
    Higgins, W. E.
    Khare, R.
    Cornish, D. C.
    Byrnes, P. D.
    Cheirsilp, R.
    Zang, X.
    Toth, J. W.
    Reed, M. F.
    Bascom, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189