Background: Total hip arthroplasty in patients younger than thirty years of age represents a long-term challenge. As polyethylene wear secondary to a high activity level could be problematic, hard-on-hard bearings have been proposed to reduce wear. The aim of this retrospective case series was to assess the clinical and radiographic results of primary metal-on-metal total hip arthroplasty in patients thirty years of age or younger. Methods: We retrospectively studied thirty-four patients (forty-seven hips) who had undergone metal-on-metal total hip arthroplasty and analyzed the radiographic and clinical measurements after a mean duration of follow-up of 108 months (range, 62.4 to 153.6 months). The mean age of the patients at the time of surgery was twenty-five years (range, fifteen to thirty years). The diameter of the head of the femoral component was 28 mm in all hips except five, in which it was 32 mm. The metal-on-metal bearing was the same in all patients. Results: The mean Merle d'Aubigne score increased from 10.6 (range, 1 to 14) to 17.1 (range, 12 to 18). No wear was found on the latest radiograph, but osteolysis was noted in three femora and two acetabula. Two revisions were performed, one because of impingement secondary to cup malorientation and the other because of acetabular loosening with osteolysis. Kaplan-Meier analysis with revision of either component as the end point revealed a ten-year survival rate of 94.5% (95% confidence interval, 80% to 98.6%). The survival rate of the femoral stem was 100%. Conclusions: These encouraging intermediate-term results indicate that hip arthroplasty with metal-on-metal bearing components may be a suitable solution for young and active patients with hip osteoarthritis or osteonecrosis of the femoral head.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 50 条
  • [41] Is Metal-on-Metal Total Hip Arthroplasty Still an Alternative?
    Akisue, Toshihiro
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (18):
  • [42] Metal-on-metal articulation in total hip arthroplasty: update
    Srinivasan, Anand
    Levine, Brett R.
    Jacobs, Joshua J.
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (03): : 231 - 235
  • [43] EVIDENCE ON SAFETY OF METAL-ON-METAL HIP RESURFACING ARTHROPLASTY
    Sehatzadeh, S.
    Levin, L.
    VALUE IN HEALTH, 2013, 16 (03) : A220 - A220
  • [44] MRI Findings in Painful Metal-on-Metal Hip Arthroplasty
    Hayter, Catherine L.
    Gold, Stephanie L.
    Koff, Matthew F.
    Perino, Giorgio
    Nawabi, Danyal H.
    Miller, Theodore T.
    Potter, Hollis G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (04) : 884 - 893
  • [45] Pseudotumor in the Setting of Metal-on-Metal Total Hip Arthroplasty
    Sagoo, Navraj S.
    Sharma, Ruhi
    Johnson, Connor S.
    Stephenson, Kelly
    Aya, Kessiena L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [46] Management of failed metal-on-metal total hip arthroplasty
    Griffin, Justin W.
    D'Apuzzo, Michele
    Browne, James A.
    WORLD JOURNAL OF ORTHOPEDICS, 2012, 3 (06): : 70 - 74
  • [47] Revision Total Hip Arthroplasty for Aseptically Failed Metal-On-Metal Hip Resurfacing Arthroplasty
    Salmons, Harold I.
    Fruth, Kristin M.
    Lewallen, David G.
    Trousdale, Robert T.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2399 - 2405
  • [48] Outcome of Revision Total Hip Arthroplasty in Management of Failed Metal-on-Metal Hip Arthroplasty
    Rahman, Wael A.
    Amenabar, Tomas
    Hetaimish, Bandar M.
    Safir, Oleg A.
    Kuzyk, Paul R.
    Gross, Allan E.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (11): : 2559 - 2563
  • [49] Quality of life in different age groups after metal-on-metal hip resurfacing arthroplasty
    Papavasiliou, A. V.
    Villar, R. N.
    HIP INTERNATIONAL, 2008, 18 (04) : 307 - 312
  • [50] 11-Year outcomes in patients with metal-on-metal ASR hip arthroplasty
    Bitar, Christian
    Moberg, Ivan
    Krupic, Ferid
    Wretenberg, Per
    Otten, Volker
    Crnalic, Sead
    JOURNAL OF ORTHOPAEDICS, 2022, 32 : 98 - 103