Comparison of volume doses from conventional two-dimensional brachytherapy with corresponding doses from three-dimensional magnetic resonance imaging-based brachytherapy in carcinoma cervix

被引:2
|
作者
Mathews, Susan [1 ]
Azariah, M. Biju [1 ]
Mohandas, Seetha [4 ]
Menon, Sharika V. [2 ]
George, Preethi [3 ]
Jayaprakash, P. G. [4 ]
机构
[1] SUT Hosp, Dept Radiat Oncol, Thiruvananthapuram, Kerala, India
[2] SUT Hosp, Dept Radiat Phys, Thiruvananthapuram, Kerala, India
[3] SUT Hosp, Reg Canc Ctr, Dept Bio Stat, Thiruvananthapuram, Kerala, India
[4] SUT Hosp, Dept Clin Oncol, Thiruvananthapuram, Kerala, India
关键词
Carcinoma cervix; dosimetry; image-based brachytherapy; CANCER; ULTRASOUND; RECOMMENDATIONS;
D O I
10.4103/jcrt.JCRT_992_17
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to evaluate the doses delivered to the brachytherapy (BT) target volume and organs at risk from two-dimensional X-ray-based plans on magnetic resonance imaging (MRI) and to compare these doses with the corresponding doses from the image-based optimized plans.Materials and Methods: Twenty patients with cervical cancer treated with chemoradiation and BT were included in this study. All patients had two sets of treatment plans generated for the first fraction of BT. Volume doses resulting from MRI-based optimized plans were compared with the corresponding doses from standard "Point A" prescription plans.Results: There was statistically significant difference between the two planning modalities for the mean high-risk clinical target volume (HRCTV) D90 doses (P = 0.0014) although mean D2cc of bladder (P = 0.1667) and rectum (P = 0.051) was not different. Standard plans with a prescription dose of 7 Gy to Point A delivered a mean HRCTV D90 of 10.07 Gy in patients with no gross residual disease at the time of BT, which was very similar to the mean dose from MR-based plans (MRI 10.02 Gy and standard 10.07 Gy). The only factor seen affecting dose distribution in this group was the applicator geometry. Standard plans failed to deliver HRCTV D90 doses of >8.5 Gy in all patients with gross residual disease. The doses were <7.00 Gy to the HRCTV in three patients who had maximum residual diseases at the time of BT.Conclusion: Conventional X-ray-based plans with moderate Point A doses deliver HRCTV D90 comparable to MRI-based plans in patients with no residual disease, and centrally placed residual disease, provided proper applicator placement and ideal geometry can be ensured. Soft-tissue image-based BT dose optimization ought to be considered in all patients with gross residual disease at the time of brachytherapy.
引用
收藏
页码:1332 / 1337
页数:6
相关论文
共 50 条
  • [31] Quantitative differentiation of breast lesions based on three-dimensional morphology from magnetic resonance imaging
    Shahar, KH
    Solaiyappan, M
    Bluemke, DA
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) : 1047 - 1053
  • [32] Monitoring of lung motion in patients with malignant pleural mesothelioma using two-dimensional and three-dimensional dynamic magnetic resonance imaging - Comparison with spirometry
    Plathow, C
    Klopp, M
    Schoebinger, M
    Thieke, C
    Fink, C
    Puderbach, M
    Ley, S
    Weber, MA
    Sandner, A
    Claussen, CD
    Herth, F
    Tuengerthal, S
    Meinzer, HP
    Kauczor, HU
    INVESTIGATIVE RADIOLOGY, 2006, 41 (05) : 443 - 448
  • [33] THREE-DIMENSIONAL RECONSTRUCTION OF MALE PELVIC ANATOMY FROM MAGNETIC RESONANCE IMAGING
    Rajasekaran, M. Raj
    Trivedi, Ishika
    Sinha, Shantanu
    Bhargava, Valmik
    JOURNAL OF UROLOGY, 2017, 197 (04): : E1094 - E1095
  • [34] Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with two-dimensional echocardiography and magnetic resonance imaging
    Bicudo, L.
    Tsutsui, J.
    Shiozaki, A.
    Rochitte, C.
    Arteaga, E.
    Mady, C.
    Mathias, W.
    CIRCULATION, 2008, 118 (12) : E421 - E421
  • [35] A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging
    Roy-Lacroix, M. E.
    Moretti, F.
    Ferraro, Z. M.
    Brosseau, L.
    Clancy, J.
    Fung-Kee-Fung, K.
    JOURNAL OF PERINATOLOGY, 2017, 37 (04) : 380 - 386
  • [36] A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging
    M E Roy-Lacroix
    F Moretti
    Z M Ferraro
    L Brosseau
    J Clancy
    K Fung-Kee-Fung
    Journal of Perinatology, 2017, 37 : 380 - 386
  • [37] Agreement of two-dimensional and three-dimensional transvaginal ultrasound with magnetic resonance imaging in assessment of parametrial infiltration in cervical cancer
    Chiappa, V.
    Di Legge, A.
    Valentini, A. L.
    Gui, B.
    Micco, M.
    Ludovisi, M.
    Giansiracusa, C.
    Testa, A. C.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (04) : 459 - 469
  • [38] Combination of tomographic ultrasound imaging and three-dimensional magnetic resonance imaging-based model to diagnose postpartum levator avulsion
    Yulin Yan
    Chaoran Dou
    Xia Wang
    Yan Xi
    Bing Hu
    Li Ma
    Tao Ying
    Scientific Reports, 7
  • [39] Can Three-Dimensional Echocardiography Replace Two-Dimensional Biplane Simpson's Method? A Comparison of Fully Automated Three-Dimensional Transthoracic Echocardiography and Cardiac Magnetic Resonance Imaging for Quantification of Left Ventricular Volume and Ejection Fraction
    Mehta, Hirsch S.
    Kabra, Ashish N.
    Mohan, Rajeev C.
    Billick, Kristen
    Sato, Karoline
    Smith, Michael R.
    Rubenson, David S.
    CIRCULATION, 2013, 128 (22)
  • [40] Combination of tomographic ultrasound imaging and three-dimensional magnetic resonance imaging-based model to diagnose postpartum levator avulsion
    Yan, Yulin
    Dou, Chaoran
    Wang, Xia
    Xi, Yan
    Hu, Bing
    Ma, Li
    Ying, Tao
    SCIENTIFIC REPORTS, 2017, 7