Microelectrodes for in situ voltammetric determination of pollutants

被引:1
|
作者
Paux, T
Billon, G
Pieta, I
Ouddane, B
Fischer, JC
Wartel, M
机构
[1] Univ Sci & Technol Lille 1, Equipe Chim Analyt & Marine, Lab ELICO, UMR 8013,CNRS, F-59655 Villeneuve Dascq, France
[2] Ruer Boskovi Inst, Ctr Marine & Environm Res, Zagreb 10002, Croatia
来源
JOURNAL DE PHYSIQUE IV | 2003年 / 107卷
关键词
D O I
10.1051/jp4:20030567
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The toxicity of sediments is often closely bound to the labile toxic elements contents. In porewaters, metal concentrations are generally measured after separation from the solid material by means of pressure or centrifugation. The recent developments of in situ metal measurements by microsensors do not require any pretreatment of the sediment and hence avoid some possible artefacts like oxygen penetration in anoxic sediment and/or temperature modification. Our work describes firstly the preparation of microelectrodes based on a thin solid Silver (diameter: 30 mum) or Iridium (diameter: 75 mum) wire, covered at the tip with a fine layer of mercury. Secondly, an analytical procedure (based on cathodic voltammetry) is presented to measure Mn(II), Fe(II) and S(-II) concentrations, which play a relevant role in the metal pollutant cycle in sediments. By anodic stripping voltammetry, such microsensors are able to detect trace heavy metals such as Cd(II) or Pb(II) at relatively low concentration levels (similar to 1 mug.dm(-3)) with 5 minutes accumulation time. Finally, the most important challenge is to install the microelectrodes in natural media and to follow up metal pollution over a long time period.
引用
收藏
页码:1413 / 1416
页数:4
相关论文
共 50 条
  • [31] VOLTAMMETRIC MEASUREMENTS WITH MICROELECTRODES IN LOW-CONDUCTIVITY SYSTEMS
    PENA, MJ
    FLEISCHMANN, M
    GARRARD, N
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 220 (01) : 31 - 40
  • [32] Voltammetric Detection of Hydrogen Peroxide at Carbon Fiber Microelectrodes
    Sanford, Audrey L.
    Morton, Stephen W.
    Whitehouse, Kelsey L.
    Oara, Hannah M.
    Lugo-Morales, Leyda Z.
    Roberts, James G.
    Sombers, Leslie A.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5205 - 5210
  • [33] EPOXY-BONDED GRAPHITE MICROELECTRODES FOR VOLTAMMETRIC MEASUREMENTS
    WANG, J
    ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2280 - 2283
  • [34] VOLTAMMETRIC STUDIES BEYOND THE SOLVENT LIMITS WITH MICROELECTRODES.
    Malmsten, Richard A.
    White, Henry S.
    1600, (133):
  • [35] Voltammetric determination of maleic and fumaric acids at an in situ renewed graphite electrode
    Tarasova, VA
    Kiryushov, VN
    Bek, RY
    JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (06) : 565 - 568
  • [36] Voltammetric Determination of Maleic and Fumaric Acids at an In Situ Renewed Graphite Electrode
    V. A. Tarasova
    V. N. Kiryushov
    R. Yu. Bek
    Journal of Analytical Chemistry, 2003, 58 : 565 - 568
  • [37] Sensitive voltammetric determination of rutin at an in situ plated lead film electrode
    Tyszczuk, Katarzyna
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 558 - 561
  • [38] Electrooxidation and electroreduction of undiluted acetonitrile at platinum microelectrodes. In situ determination of water in acetonitrile
    Zieja, J
    Gadomska-Trzos, J
    Stojek, Z
    ELECTROANALYSIS, 2001, 13 (8-9) : 621 - 625
  • [39] TOTAL ANODIC VOLTAMMETRIC WAVES OF UNDILUTED DIMETHYLSULFOXIDE AT PT MICROELECTRODES
    KONCKA, M
    STOJEK, Z
    ELECTROANALYSIS, 1995, 7 (11) : 1010 - 1014
  • [40] Indirect voltammetric analysis of fluoride ions in toothpaste at IDA microelectrodes
    Rievaj, Miroslav
    Svorc, L'ubomir
    Tomcik, Peter
    Cernanska, Monika
    Bustin, Dusan
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 127 - 131